POWER TROUBLESHOOTING INDEX 

 

 

1.

 

No Power to Unit, LED Panel does not Illuminate 

 

2.

 

Compressor Runs but does not Chill 

 

3.

 

Compressor is not Running 

 

4.

 

Unit has Power, but Water is not Chilled or Heated 

 

5.

 

Unit has Power, LED Panel does not Illuminate or only partially Illuminates 

  
 

 

1.

 

No Power to Unit, LED Panel does not Illuminate 

 

Possible Cause 

Solution 

Circuit Breaker tripped 

Check the circuit breaker, reset any tripped breaker. 

Blown Fuse 

Check Fuse in Unit Replace if necessary.  

Loose Power Cord 

Check that the power cord is properly plugged in.  

PCB Failure 

Check the PCB for Power incoming and outgoing.  

 
 

2.

 

Compressor Runs but does not Chill 

 

Possible Cause 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow 

across condenser coils 

Make sure unit is not under minimum ventilation 

requirements.  

Compressor very hot to 

the touch 

Low or lost refrigerant. Refrigerant recharge required.  

 
 
 
 