WL500
Manual
Page 23 Revision 4‐10‐2019
PROGRAMING MENU AND SELECTIONS
Menu
Options
Brief Description
Cold Temp Set
3° ‐ 12°C
The cold temperature can be set between 3°C and 12°C or 37°F and 54°F,
depending on which units are selected (°C or °F) in the F/C option.
37° ‐ 54°F
Recommended/Default Setting is 5°C/41°F.
Hot Temp Set
70°C ‐ 95°C
The hot temperature can be set between 70°C and 95°C or 158°F and
203°F, depending on which units are selected (°C or °F) in the F/C option.
158°F ‐ 203°F
Recommended/Default Setting is 87°C/189°F.
Temp Display
Static
The display indicates the STATIC (SET POINT) temperature.
Default
Ranging
The display indicates the ACTUAL tank temperature
UV Timer
3 minutes
The UV Lamp lights every time you take a drink of cold water, and stays on
for 3 minutes
.
Recommended/Default Setting is 3 minutes
10 minutes
The UV Lamp lights every time you take a drink of cold water, and stays on
for 10 minutes.
Constant
The UV Lamp stays on when power is on.
Not Recommended
F/C
F
Temperatures are displayed in degrees Fahrenheit.
Default is
o
F
C
Temperatures are displayed in degrees Celsius.
Language
English
The display will read in English.
Default is English
Spanish
The display will read in Spanish
French, Etc.
The display will read in French, and many others…
Flow Counter
Liters
(4000‐9000)
DO NOT USE
. “NO WATER SUPPLY” Fault will occur. Use Filters Timer
Instead.
Gallons
(1000‐3000)
DO NOT USE
.
“NO WATER SUPPLY” Fault will occur. Use Filters Timer
Instead.
Filters Timer
3 months
Timer for Filters Life set at 3 months. Displays “Change Filters” after 3
months
6 months
Timer for Filters Life set at 6 months. Displays “Change Filters” after 6
months
9 months
Timer for Filters Life set at 9 months. Displays “Change Filters” after 9
months
None
Timer for Filters Life is turned off.
Default is None
Filters Life
00
DAYS
Indicates amount of water flowed(gal/liters) or days elapsed since last
reset
Ensure Filters Timer is enabled and Filters Life indicates DAYS
Energy Saving Sleep Mode
On
Shuts heater down (hot water) if not used in 3 hours. –
Default Sleep is ON
Off
Hot water remains powered indefinitely.
Default Set
Cold
Defaults Display & Dispense Selection to Cold after 3 seconds.
Default is
Cold
Sparkling
Defaults Display & Dispense Selection to Sparkling after 3 seconds.
Reset
OK?
Resets the Filters Life to zero. Confirm by selecting Button 3 (Hot) to Save
and Exit. This resets the timer.