background image

 

WL2FLT Manual                                                                                                                                 Page 41 – Revision 7-19-21 

POWER TROUBLESHOOTING INDEX 

 

  

1.  Red Heater & Compressor Power Switch won't light and the Red LED on the Front 

won't light 
 

2.  Red Heater & Compressor Power Switch is lit but the red LED on the Front is not lit 
 
3.  Compressor Runs but does Not Chill 

 

4.  Compressor is Not Running  

 

 

1.

 

Red Heater and Compressor Power Switch won’t light and the Red LED on the 

Front won’t light 

 

 

Possible Reason 

Solution 

Circuit Breaker 

Check the Circuit Breaker 

Fuse is Blown 

Replace Fuse 

Defective / Loose Power Cord  Check that Power Cord is properly plugged in.  If it is properly 

plugged in, use a different power cord to verify. 

Failed Socket - Power Line 

Noise Filter, ElectroMagnetic 

Interference filter (EMI) 

Replace Socket - Power Line Noise Filter, ElectroMagnetic 

Interference filter (EMI)

 

Defective Red Heater & 

Compressor Switch 

Replace Red Heater & Compressor Switch 

 

 

 

 

 

 

 

 

 

Отзывы: