Waterdrop WD-WHF21-PG Скачать руководство пользователя страница 10

Note:

 If there is a sealing ring left by the old filter element in the filter bottle, please 

take out the sealing ring and put it in the filter element.

Step 4: Flush the system

Flush the system by turning on a few cold-water faucets. Allow the water to run until 
the air and carbon has been purged. Water may be cloudy initially as the filters and 
system clear of trapped air. New activated carbon filter cartridges may contain loose 
carbon and air bubbles after installation

.

Frequently Asked Questions

Q: Why does water leak from the housing connection?
A: 

The O-ring may not be in place or not enough teflon tape on the threads. Reapply 

teflon tape and tighten. If it still leaks after adjusting the O-ring or threads, please 
contact us.

Q: Why does water leak from the pressure release button?
A: 

The pressure release button has a screw under the bracket. Simply tighten that 

screw and the leaking should stop.

Q: Why does water appear cloudy and gray?
A: 

Water may appear cloudy or gray for the first 1-2 days after installation due to the 

tiny air bubbles being purged from the flters and extra carbon dust in the water.

Q: Why does water pressure slow after a period of time?
A:

 It is recommended that the cartridges be replaced every 3-6 months depending 

on the amount of contaminants present in the water supply. If the system has been 
working properly and the pressure is slowing, it may be time to change the filter 
cartridge.

Q: Why does water pressure slow immediately after installation?
A: 

The cartridges may be installed incorrectly. Check to see if a piece of the plastic 

wrapping is still protecting the filter cartridges. Bathtubs, utility sinks, hose bibs, 
multi-headed showers,body sprayers, or anything that is considered high-fow should 
be avoided for the first 72 hours. Any high-fow situation within the first 72 hours may 
cause a temporary carbon blockage. To clear the blockage, turn of any running water 
for at least 10 minutes and resume using water at low or normal fow rates.

Step 2: Measure the system and cut the pipe

 

(Figure 3)

Determine location and water flow direction for the system. Cut off the appropriate 
length of PEX pipe. Fix the pipe on the system with two 1’’. Stainless Steel PEX Barb 
Pinch Clamps. Pay attention to the water inlet direction, and do not install it in the 
opposite direction. You can also use an expansion ring to fix the pipe.

Step 3: Fix the whole house filter 

(Figure 4)

Securely mount the whole house filter bracket and ensure the system is level.

Notice: 

Fit pipe hanger (not included) on water INLET and OUTLET side for addition-

al support.

3

1

2

4

5

6

7

8

Содержание WD-WHF21-PG

Страница 1: ...User Manual 1 2 Stage Whole House Water Filtration System Read this manual before using and keep it for future reference...

Страница 2: ......

Страница 3: ...tents Product Operation and Specifications 2 Components List 2 Tools Required 2 Pre installation 3 Installation 3 Maintenance Instructions 6 Filter Change Instructions 7 Frequently Asked Questions 8 W...

Страница 4: ...to 6months Lifetime upto 6months Safety glasses Towels Flat head screwdriver Medium crescent wrench Hacksaw Soldering iron or torch Adjustable wrench Teflon tape 1 Metal filter housing scraper 2 10 4...

Страница 5: ...Allow the cut line to drain Smooth the newly cut ends down to avoid jagged points or edges A three valve bypass valve and loop may be installed to loop the entire system to make servicing easier The...

Страница 6: ...in the figure Figure 2 1 Brass PEX A Expansion Barb x 1 MNPT Male Adapter Step 2 Measure the system and cut the pipe Figure 3 Determine location and water flow direction for the system Cut off the ap...

Страница 7: ...ted Continue to run water until it runs clear and all air has been purged Shut the water off and let the unit sit for a while and then flush again It is not unusual for the water to appear cloudy for...

Страница 8: ...ap more than 10 turns of Tefon tape on the Brass PEX A barb x MNPT male adapter external thread of the adapter Screw one end of the male thread into the FNPT 1 MNPT adapter and tighten it with a wrenc...

Страница 9: ...ed with about 2 tablespoons of household bleach using a sponge or soft rag Wear rubber gloves Rinse all parts very thoroughly 2 Lubricate the O ring with clean silicone grease if needed DO NOT USE PET...

Страница 10: ...should stop Q Why does water appear cloudy and gray A Water may appear cloudy or gray for the first 1 2 days after installation due to the tiny air bubbles being purged from the flters and extra carb...

Страница 11: ...ditions outside listed operating parameters use in commercial operations or any other manner outside the product specifications set forth in the owner s manual Our obligation does not include the cost...

Страница 12: ......

Отзывы: