Make sure to place the pads on the right components.  
 
No.1 – thermal pad 0,25mm height (color blue) 
No.2 – thermal pad 1,00mm height (color light blue) 
 
Instead of the thermal pads, you can use a non-conductive thermal compound on the RAM components, which 
slightly increases the cooling capacity in this area. 
Apply the thermal compound to the GPU area evenly.

 

 

Assembly of the cooler 

 
Put the cooler onto the prepared graphics card and then turn the components around. The cooler is delivered with 
8x M3x8mm plastic screws and washers. 
Screw the screws – with washers – into the cooler beginning with the GPU area. 
Do not tighten the screws yet! 
In case of the GPU-X³ GTX480, place the backplate included in delivery on the graphics card and loosely screw it 
to the cooler (without washers). 
 
Once all screws are attached to the cooler, screw them tight beginning with the GPU area. Make sure to tighten 
the screws crosswise. 

 

 

Installation and leak test 

 
After the installation, a check and test run must be performed! The coolers are constructed on the reference 
design, still, all sections of the board have to be checked for possible contact to the cooler. In addition, the contact 
of the GPU to the cooler must be checked along with the bending of the board. A slight bending of the board is 
normal.

 

A leak test should preferably be performed outside of the computer. If this is not possible, the hardware may not 
be turned on during the test run!

 

Once all of the cooler elements were tested, the computer can be put into operation. Check the temperature of 
the GPU immediately after the start! 
 

General information 

 
The HEATKILLER® GPU-X³ GTX465/470 and GTX480 does not have a defined input and output. The cooling 
medium can stream in or our on both sides.

 

Under normal circumstances it is not necessary to open the cooler. If you still want to do so, please use a 
corresponding tool for Allen screws in industrial quality. 

 

We recommend using demineralised or deionised water (distilled water) as cooling medium. To prevent the build-
up of algae, use common citric acid, which reliably prevents the spread of algae.

 

The cooler is fully SLI compatible. To set up a dual or triple SLI system, we offer special dual and triple links 
which allow you to easily connect the coolers. 
 