OXISWIM MANUAL
P a g e
12 | 45
5
INSTALLATION GUIDE
The Oxiswim system can be fitted into most types of pools or spas. In addition, the system
can be retrofitted into other existing sanitisation systems to complement the operation of
the existing system.
5.1
Water Chemistry
When operating with hydrogen peroxide, the following operating parameters are
recommended
Test
Result
Perox Pro (Hydrogen Peroxide)
100ppm - 300ppm
pH level
7.2 - 7.6
Total Alkalinity level
60ppm - 80ppm
Calcium Hardness
180ppm - 400ppm
Salinity (= total Pool salt & Mineral Crystals) For low salt
cell use*
2000ppm-3000ppm
Phosphate level
Less than < 0.5ppm
Chlorine Dioxide
0.4ppm - 0.5 ppm
Содержание OXISWIM
Страница 1: ...D U A L S A N I T I S A T I O N Installation and Operation manual Version 1 1 3 December 2022 ...
Страница 11: ...OXISWIM MANUAL P a g e 11 45 INSTALLATION AND COMMISSIONING ...
Страница 15: ...OXISWIM MANUAL P a g e 15 45 Oxiswim Typical Installation Layout ...
Страница 28: ...OXISWIM MANUAL P a g e 28 45 OPERATION AND MAINTENANCE ...