4.5 Overfill Protection Switch (OPS) for the Raw Water Tank
The
O
verfill
P
rotection
S
witch (
OPS
) is to be installed in the RWT. This switch
determines the maximum water level at which the feed pump must be switched
off. By this, overfilling of the RWT will be prevented.
Concerning the necessary connections, please refer to the instructions provided
with the OPS. The black wire is the zero connector. We recommend to test
whether the blue or the brown wire is to be used besides the black wire.
4.6 Run-Dry Protection Switch (RPS)
It is highly recommended to prevent the feed pump that is used for raw water
pumping from running dry. This can be done by using a
R
un-dry
P
rotection
S
witch (
RPS
) and realize the wiring according to this task, which means that the
black wire is used and the second wire to be used is the opposite one com-
pared with the wiring needed for overfill prevention at the OPS. We recommend
to test whether the blue or the brown wire is to be used besides the black wire.