Watec WAT-600CX Скачать руководство пользователя страница 1

    

Color  CCD  Camera 

 

WAT-600CX 

 

Operation Manual 

 

 

This Operation Manual covers safety, camera functions, installation and the 
correct operating procedure for the WAT-600CX. First, we ask you to read 
this Operation Manual thoroughly, then install and operate the WAT-600CX 
as advised. In addition, for future reference, we also advise safekeeping of 
this manual. 

 

Please  contact  the  distributor  or  dealer  from  which  the  WAT-600CX  was 
purchased,  if  you  do  not  understand  the  installation,  operation  or  safety 
instructions  laid  out  in  this manual.  Not  understanding  the contents  of  the 
Operation Manual sufficiently may cause damage to the camera. 

 

    

    

Guide to the Safety Symbols

                 

                 

                 

                 

 

 

The definitions of the symbols used in this operation manual are: 

 

When you do not adhere to or take notice of the “Danger” sign, 
it may lead to a serious accident such as death or injury caused 
by fire or electric shock. 

 

When you do not adhere to or take notice of the “Warning” sign, 
it may cause severe damage such as a physical injury. 

 

When you do not adhere to or take notice of the “Caution” sign, 
it may incur injury and cause damage to peripheral objects in 
the immediate surroundings. 

 

   

Cautions for Safety

           

           

           

           

         

       

       

       

       

     

    

The WAT-600CX is designed to be used safely; however, it may lead to a 
physical  accident  caused  by  fire  and  electric  shock  if  not  used  correctly. 
Therefore,  please  keep  and  read  the  “Cautions  for  safety”  below  for 
protection against accidents. 

 

 

Do not disassemble and/or modify the WAT-600CX. 

    

Do not operate the WAT-600CX with wet hands. 

    

    

    

    

 

 

Use only the AD-156 with the WAT- 600CX set

 

Do not use the WAT- 600CX under unusual environmental 

conditions. 

The WAT-600CX is designed and approved for indoor use only. 
The WAT-600CX is not water-resistant, dustproof, or 
explosion proof. If the location of the camera is outdoors or in 
an outdoor like environment, we recommend that you use an 
outdoor camera housing. 

 

Protect the WAT-600CX from condensation. 

Keep the WAT-600CX dry at all times during storage and 
operation. 

 

Should the camera not work properly, switch off the power 
immediately. Then check the camera according to the 
“Problems and Trouble shooting” section. 

 

 

 

Avoid the striking of hard objects or dropping the WAT- 

600CX. 

The WAT-600CX uses high quality electrical parts and 
precision components. 

 

The WAT-400RX must be used with the WAT-600CX.

   

Only the WAT-400RX should be attached to the WAT-600CX 
BNC terminal. Connecting a monitor directly to this terminal 
will not provide a picture.

 

 

Do  not  install  the  WAT-600CX  in  a  position  subject  to 

direct sunlight. 

Sunlight shinning directly onto the WAT-600CX lens can 
cause damage to the CCD.

   

 

Select a stable place for installation of the WAT-600CX. 

Use  a  support  of  durable  strength  around  an  installation 
position on a ceiling or wall when a camera stand or tripod is 
used. 

 

Do not move the WAT-600CX with the cables connected.

 

 

Before  moving  the WAT-600CX,  always  remove  the  cable(s) 
from the rear of the camera first. 

 

 

Avoid using the WAT-600CX near any strong 

electromagnetic field. 

After installing into main equipment, if the WAT-600CX is 
exposed to electromagnetic waves causing the monitored 
image to become distorted, we recommend the camera be 
shielded by appropriate protective casing.

 

    

    

Problems and Trouble Shooting

                                             

                                             

                                             

                                             

 

 

If any of the following problems occur when using the WAT-600CX,   

    

 

An optimal picture cannot be obtained, after checking that all the cables 

and connections are correctly in place 

 
 

 

Smoke or any unusual odor emerges from the WAT-600CX

 

 
 

• 

An  object  becomes  embedded  or  a  quantity  of  liquid  seeps  into  the 
camera housing 

 
 

• 

More than the recommended voltage or/and amperage has been applied 
to the WAT-600CX by mistake

 

 

 

• 

Anything unusual occurring to any equipment connected to the WAT- 

600CX

 

    

disconnect the camera immediately according to the following 
procedures: 

    

Switch off the main power supply to the camera.

   

 

 

Remove the cable(s) connected to the WAT-600CX. 

 

Contact the distributor or dealer from which the WAT-600CX was   
purchased. 

 

    

About EMC                             

                 

                 

                 

                 

 

 

The WAT-600CX is in conformity with EMC test standards carried out by 
authorized organizations in Japan.

   

 

 

 

NTSC   

 

FCC Part15 class B

 

 

     

P

 

A

 

L      EN61000-6-3/EN50130-4 

 

Do not modify the WAT-600CX. A modified camera may not 
conform to EMC test standards. 

    

    

Contents   

                             

                             

                             

                             

 

           

           

           

           

 

 

Using the contents figures below, check to make sure all parts are present 
before use. 
 

 
 

 

 

 

 
 
 
 
 

 

Lens            WAT-

600CX

                 

DC Plug              AC Adaptor (AD-156) 

Mount Cap 

    

    

Description of Parts

                                             

                                             

                                             

                                             

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CCD FRONT FACE 

The light receiving face of the CCD camera 

(Dirt, water or oil deposits on the CCD will cause an unclear picture on   
the  monitor.  Attach  the  lens  cap  to  protect  the  lens  and  the  CCD  from 
contamination and damage.) 

 

LENS MOUNT 

Mount for the lens (CS-mount) 

 

IRIS LEVEL VOLUME 

By controlling the volume, the iris level of the DC iris lens can be adjusted. 

 

FOCUSING ADJUSTMENT SCREWS

 

There are 3 hex. adjustment screws each placed at intervals of 120

for   

fine focusing of the lens. 

 

AUTO-IRIS SOCKET 

This socket is for the video/DC auto-iris lens cable connector.   

(Video/DC: Auto selected by the camera) 

 

TRIPOD MOUNTING SCREW HOLES 

Mounting holes for stands. The size of these threads are 1/4”, 20 threads, 
4.5

±

0.2mm, which is the same as any standard camera tripod (U1/4”). 

 

AE MODE CONTROL 

The switch for the shutter speed mode control according to the object 
being monitored. 

 

TEST VIDEO OUT (RCA) 

The video out terminal for test monitoring at the camera location. 

 

VIDEO OUT/POWER IN (BNC) 

The terminal for composite video signal output and power input 

 

WHITE BLEMISH CORRECTION 

The button for correction of white blemish.

 

 

FUNCTION SWITCHES 

Functional  switches  for  setting  AGC,  gamma  control,  BLC  (Back  light 
compensation), video level, and white balance modes. 

 

PUSH-LOCK WHITE BALANCE BUTTON 

The button for manual setting of the white balance if the white balance 
mode is set to PWB. 

 

    

Auto-iris Lens                                                   

                           

                           

                           

                           

 

 

Before  connecting  the  auto-iris  lens,  please  make  sure  that  the  pin 
configuration  is  correct  by  confirming  with  the  following  table.  If  the 
configuration of your iris connector is different from the following, the plug 
and pins will need to be rewired. 

 

Pin No. 

EIAJ Video 

Auto-iris Lens 

Arrangement 

EIAJ DC 

Auto-iris Lens 

Arrangement 

 

 

Power 

Control

 

 

 

Not used 

Control

 

 

 

Iris signals 

Drive

 

 

 

Common (GND) 

Drive

 

 

 

Maximum cable length for operation of the WAT-600CX depends on which 

lens is used. For example, 100m is the maximum cable length for the 
WAT-600CX when an auto-iris lens with a current consumption of 50mA 
is applied.

 

 

 

Wiring Diagram

                                 

                                 

                                 

                                 

     

     

     

                                 

                           

                           

                           

    

 

The following diagram is the basic connection of the WAT-600CX, WAT- 
400RX, AD-156 and monitor. 

 

    

Set-up and Operation

                                 

                                 

                                 

                                 

 

1)

 

Ensure that the power to the WAT-600CX and the peripheral equipment   

is turned off before making any connections. 

 

2)

 

Remove the lens mount cap from the WAT-600CX and attach the   

CS-mount lens. Use the optional C-mount adaptor (30CMA-R) when a   
C-mount lens is used.   

 

3)

 

Connect the iris control cable to 

AUTO-IRIS SOCKET on the WAT- 

600CX when an auto-iris lens is being used. 

 

4) Connect 

VIDEO OUT/POWER IN of the WAT-600CX to the 

“CAMERA” connection terminal of the WAT-400RX. Use a coaxial cable 
with 75

Ω

  impedance, such as an RG-58/U. The maximum cable length 

for the WAT-600CX attached to a manual iris lens is 150m using an 
RG-58/U cable. 

 

5)

 

Connect  the  VIDEO  OUT  (MONITOR)  on  the WAT-400RX  to  the  video 

signal  input  terminal  of  a  monitor  using  a  coaxial  cable  with  75

Ω

 

impedance, such as an RG-58/U.   

 

Select a monitor with the same television system as the WAT-600CX:   

NTSC or PAL. A monitor with more than 600TV lines is recommended. 

 

Do not connect the WAT-600CX or the WAT-400RX  with any monitor 
using  a  video  in/power  out  single  transmission  terminal.  The 
WAT-600CX  and  the  WAT-400RX  are  not  designed  for  use  with  this 
type  of  equipment  and  receiving  power  through  a  monitor  will  cause 
damage to both the WAT-600CX and the WAT-400RX. 

 

6) Connect the attached AC adaptor (AD-156) to the POWER IN connector 

of the WAT-400RX. 

 

7) When a monitor test of the camera angle of view and functional settings 

at  the  location  is  required,  connect 

TEST  VIDEO  OUT  of  the 

WAT-600CX to the monitor using a coaxial cable with 75

Ω

  impedance, 

such as an RG-58/U. 

 

8)

 

Turn on the power to the WAT-600CX, monitor and all the other allied 

equipment. When a picture cannot be obtained on the monitor, check 
and follow the procedure mentioned in the “Problems and Trouble   
Shooting” section.

 

 

9)

 

After following the procedure below and the picture is still out of focus,   

open  the  iris  fully  and  loosen 

FOCUSING  ADJUSTMENT  SCREWS 

with the hex. wrench and move the lens forwards until a clear picture is 
obtained. 

 

Manual Lens 

Adjust the focus and iris to the best position

 

on the lens. 

Video Auto-iris Lens 

Adjust the focus on the lens. 

DC Auto-iris Lens 

Adjust  the  iris  level  on  the  camera,  then 
adjust the focus on the lens. See below. 

 

Iris Level Adjustment (for DC auto-iris lenses only) 

Adjust 

IRIS LEVEL VOLUME placed on the side   

of the unit until an acceptable light level is attained. 
No change will occur if a video iris lens or manual   
iris lens is fitted. 

 
10)

 

Select any required shutter speed mode by the 

AE MODE   

CONTROL. (Factory default: EI) 

 

 

AE Mode 

Effect 

OFF 

Fixes the shutter speed to NTSC1/60, PAL1/50. 

FL 

Reduces the flickering phenomena occurring on the   
monitor screen caused by fluorescent or mercury   
lamps. 

1/1000

 

Fixes the shutter speed to 1/1000 

EI 

(Flicker suppress) 

For electronic iris reducing the flickering phenomena   
occurring on the monitor screen caused by   
fluorescent or mercury lamps. 

 

In EI mode, intense light may leave a trail on the screen longitude.   

This smearing is a natural phenomenon and is not due to equipment 
failure or fault. 

 

 

 

Danger

 

Danger

 

Danger

 

 

Warning

LEVEL

CLOSED

OPEN

 

Caution

 

Warning

 

Caution

Hex. 

Wrench 

Receiver 