Instructions for installing the WatcoFlex

®

 Direct Drain Tee Models

IMPORTANT: 

WatcoFlex

®

 

Before installing

, verify that this WatcoFlex

®

 

2

3

4

6

7

1

11

5

10

9

8

7a

7b

Installing the Flex916 & Flex924 Innovator

®

 Sanitary Tee Models

 

90145 - Flex Inst. - 7/16

WATCO MANUFACTURING COMPANY

1220 South Powell Road  •  Independence, MO  64057-2724

Phone: 816-796-3900  •  800-821-8576  •  Fax: 816-796-0875  •  800-399-2826

www.watcomfg.com

90145 - Flex Inst. - 7/16

WATCO MANUFACTURING COMPANY

1220 South Powell Road  •  Independence, MO  64057-2724

Phone: 816-796-3900  •  800-821-8576  •  Fax: 816-796-0875  •  800-399-2826

www.watcomfg.com

For Assistance, call:

800-821-8576

Monday-Friday: 7:30 a.m. - 5:00 p.m. CT

For Assistance, call:

800-821-8576

Monday-Friday: 7:30 a.m. - 5:00 p.m. CT

See watcomfg.com or call for details of applicable patents and patents pending.

See watcomfg.com or call for details of applicable patents and patents pending.

Step 1:

 Secure the drain tee 

(Item 7a)

(Item 6)

 under the tub 

by screwing in the strainer body 

(Item 5)

 through the tub drain hole from 

inside the tub. 

DO NOT USE OIL-BASED PUTTY PRODUCTS: Watco 

does not recommend and does not warrenty this product when oil/

petroleum based products are used when installing this product.

Step 2:

 

(Item 8)

(Item 7b)

.

Step 3:

 

from the back of the tub.

Step 4:

 Screw on the retainer nut 

(Item 9)

 from inside the tub. 

HAND TIGHTEN ONLY.

 

If not testing the bath waste, skip to Step 6.

Step 5:

 Screw the strainer test plug 

(Item 11)

 into the strainer body 

(Item 5)

 and test 

the system. Once testing is complete, remove the strainer test plug 

(Item 11)

.

Step 6:

 

(Item 7b)

.

Step 7:

 

(Item 10)

 with slot facing downward.

Step 8:

 Install stopper assembly 

(Items 1–4)

 into the strainer body 

(#5)

Note: Items  

#1 thru #4 may vary depending on the type of stopper assembly being used.

Step 1:

  Cut the 1

1

/

2

” Schedule 40 pipe 

(#8)

 and the 1

1

/

2

(#10)

 to the 

misalignment.

Step 2:

 

(#7- #10)

.

Step 3:

  Secure drain elbow 

(#7)

(#6) 

under the tub by screwing in 

the strainer body 

(#5)

 through the tub drain hole from inside the tub. 

 

DO NOT USE OIL-BASED PUTTY PRODUCTS: Watco does not 

recommend and does not warrenty this product when oil/petroleum based 

products are used when installing this product.

Step 4:

  Place foam gasket 

(#12)

(#11)

.

Step 5:

 

back of the tub.

Step 6:

  Screw on retainer nut 

(#13)

 from inside of tub. 

HAND TIGHTEN ONLY.

 

If not testing the bath waste, skip to Step 8.

Step 7:

  Screw the strainer test plug 

(#15)

 into the strainer body 

(#5)

 and test the system. 

 

Once testing is complete, remove the strainer test plug 

(#15)

.

Step 8:

 

(#11)

.

Step 9:

 

(#14) 

with the slot facing downward.

Step 10:

 Install the stopper assembly 

(#1- #4)

 into the strainer body 

(#5)

Note: #1-#4 may 

vary depending on the type of stopper assembly used.