background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

(1) If voltage or current exceeding the input allowable voltage or 

current is applied to the input terminals, the transducer may be 
damaged. 

(2)  Apply  power  within  the  applicable  range  of  the  transducer. 

Otherwise fire, electric shock or transducer damage may result. 

(3) The contents of this instruction manual are subject to change 

without prior notice. 

(4) This instruction manual is carefully prepared. However, if any 

mistake or omission is found, contact your nearest Watanabe sales 
agent or Watanabe directly. 

(5) Make this manual available easily anytime.

 

 

■Outline 

This is a transducer which inputs various Extremely Small DC 
signals and then outputs their corresponding standardized 
signals. 
It employs a case of terminal board construction used with 3.5 
mm screw terminals and can be mounted on DIN rails in one touch. 

In addition, as its three ports of input, output and power are 
mutually isolated, an improvement in noise rejection will be 
further made, and miniaturization of equipment will also be 
realized.

 

 

■Model No. Configuration 

Each code and the standard specifications of this transducer are 
as follows.First check whether or not your desired specifications 
are correct by comparing them to the following specifications. 

(Example)

 TZ-5FA-C2L 

 TZ-5FA-□ □ □ 
 

L:50msec 

                           

Response time  H:3msec 

 

 

0: 0 to 5VDC 

1: 1 to 5VDC 

 

 

 

2: 0 to 10VDC 

3: -10 to 10VDC 

 

 

4: -2 to 2VDC 

 

 

Output code 

5: -2.5 to 2.5VDC   

 

 

6: -5 to 5VDC 

7: 0 to 4VDC 

 

 

A: 4 to 20mADC 

 

 

 

B: 0 to 20mADC 

 

 

 

Y: Special 
0: 0 to 5mVDC 

 

 

1: 0 to 10mVDC 

 

 

2: 0 to 50mVDC 

 

Input code 

3: 0 to 60mVDC 

 

 

4: 0 to 100mVDC 

 

 

A: 0 to 10μADC 
B: 0 to 100μADC 
C: 0 to 200μADC 

 

 

           Y: Special 

■Accessories 

None 

■  Input Specification               

 
 
 
 
 
 
 

 
 

 

For Code No. Y 
Limit of specifications 
Voltage input : Less than +100 mVDC and more than -100 mVDC 
Minimum span : Less than +200 mVDC and more than 5 mVDC 
Current input :  Less than +5 mADC and more than -5 mADC 

Minimum span : Less than +10 mADC and more than 10 µADC 

 

■  Output Specification 

 
 
 
 
 
 
 
 
 
 
 
 
 

For code No. Y 
Limit of specifications 
Voltage output : Less than +15 VDC and more than -12 VDC 
Minimum span : Less than +27 VDC and more than 0.06 VDC 
(Load resistance : 10kΩ at the output exceeding 10V, and a 
negative output) 
(Base accuracy : ±0.15 %F.S and temperature characteristic : 
 ±0.03 %F.S/ºC for a span of less than 1V) 
Current output : Less than +20 mADC and more than 0 mADC 
Minimum span : Less than +20 mADC and more than 1 mADC 

Outputs can be reversed for both voltage and current outputs. 
 

■General specifications 

Base Accuracy : ±0.1 %F.S (At 25±2ºC) 
Power supply variation : ±0.06 %F.S 
Load resistance variation : ±0.06 %F.S 
Temperature characteristic : ±0.02 %F.S/ºC 
Response time : Less than 50msec or 3msec (TYP)(0→90%) 
Front adjustments : ±5% for zero and span 
Insulation resistance : Between input and output/power 
supply ;More than 100MΩ at 500 VDC 
Dielectric strength : Between input and output/power supply ; 
 

For 1 min.  at 1500VAC 

Power supply voltage : 24VDC ±10 % 
Consuming current : Less than 30mA (24VDC  at voltage output) 
                   Less than 50mA (24VDC  at current output) 
Operating ambient temperature : -5 to 50ºC  
Operating ambient humidity : Less than 90 %RH  (No-condensing) 
Storage temperature : -10 to 70ºC 
Storage humidity : Less than 60%RH (No-condensing) 
Case material : ABS rasin (Black)  94V-2 
Weight : Approx. 80g 
Vibration resistance : Frequency: 10 to 55Hz; ampliutde(half): 
0.15mm to 10 sweeps of 5 min each in X, Y, and Z directions 

 

INSTRUCTION MANUAL

 

Terminal Type Extremely Small DC V/A   

MODEL TZ-5FA 

Precautions 

Warning

Warning

 

This  marking  indicates  that  the  erroneous 
operation of this transducer may result in death 
or serious injury.

 

Isolated Transducer (DC POWER) 

Output Signal

Allowable Load resistance

More than 4k

Ω

Negative output : more than 10k

Ω

 0 to 5VDC

More than 2k

Ω

Less than 550

Ω

Other than the above

 1 to 5VDC

 0 to 10VDC

 -10 to 10VDC

 0 to 20mADC

Code No.

-2 to 2VDC 

-2.5 to 2.5VDC 

-5 to 5VDC 

0 to 4VDC 

4 to 20mADC 

More than 2k

Ω

Negative output : more than 10k

Ω

More than 2k

Ω

2

0

1

3

A

Y

6

4

5

7

B

-50 to +150%F.S

More than 1M

Ω

1k

Ω

Other than the above

2

0

1

3

4

A

B

C

Y

500

Ω

Input allowable range

Input signal

Input resistance

Code No.

 0 to 5mVDC

 0 to 10mVDC

 0 to 50mVDC

 0 to 60mVDC

 0 to 100mVDC

 0 to 10

μ

ADC

 0 to 100

μ

ADC

 0 to 200

μ

ADC

Отзывы: