Doc: Transducer Installation 

Version: 2.6 May 2021

Doc: Transducer Installation
Version: 2.6 May 2021

wassp.com

wassp.com

 TRANSDUCER INSTALLATION MANUAL

 TRANSDUCER INSTALLATION MANUAL

8 CABLE CONNECTION TO DRX

Transducer Receive Channels should be discharged prior to connection to the DRX. This 
should be done 

every time

 the DRX is connected to the transducer.

To discharge the Transducer:
1. 

Peel off the cover label on DRX front panel, remove the black blanking plastic on 
the X/TX port. 

2. 

Plug each of the 7 Transducer Receive Cables into X/TX socket in turn.  

Once discharge has been performed on every cable connect each cable to the correct 
receive port on the DRX. For further information on connection to the DRX see the DRX 
Installation Manual

If this label shown in Figure 12 is not present 
on delivery, then discharge is not available 
on this DRX. In this event you may have 
been supplied with an external discharge 
module. 
If you plan to connect any transducer to a 
DRX and your unit does not have a built-in 
discharge port then we recommend you 
request an external discharge module to 
prevent damage to your DRX.

Figure 14.  DRX with the Transducer Receive 
Discharge cover label instruction

CAUTION: Failure to discharge the transducer prior to connection to the 
DRX may result in irreparable damage to the DRX.

If you have an external discharge module follow the same procedure as above but use 
the external discharge module rather than the X/TX socket to discharge the individual 
Transducer Receive Channels each time you wish to connect the transducer to the DRX. 
For the 80kHz Transducer, it is important that the receive channels are discharged prior 
to connection to the DRX.

To discharge the transducer use the supplied 
Ceramic Discharge Module (shipped with 
WASSP 80kHz Transducers).  

Figure 15.  Ceramic Discharge Module

Connect each of the 7 Transducer Receive 
Cables in turn to the RJ45 socket on the 
Discharge Module. Connection will result in 
the receive ceramics discharging through the 
module.
This procedure should be carried out no more 
that 10 minutes prior to connecting cables to 
the DRX.

Figure 16.  Discharging Transducer Channels

Содержание WMB-X230

Страница 1: ...TRANSDUCER INSTALLATION MANUAL V2 6...

Страница 2: ...ted WASSP system components DOCUMENT REVISION HISTORY REVISION DATE REASON FOR CHANGE VERSION April 2016 Compilation 1 0 June 2016 Added Technical Specification and updates 1 1 June 2017 Corrected typ...

Страница 3: ...land 25 7 3 Transducer Cable 28 7 3 1 Replacing Repairing an RJ 45 Connector29 8 Cable Connection to DRX 30 9 Technical Specification 32 10 Product Registration Support and Resources 32 FIGURES Figure...

Страница 4: ...of each individual vessel This must be sized and constructed accurately The sea chest provides a stable platform for the transducer and must be mounted as horizontal to the vessel s waterline as possi...

Страница 5: ...cer ASM SHEET SIZE DATE 200691 30 01 2020 Alexandra Oetzel Craig Shannon B C D E F A 1 8 6 7 5 4 3 2 GENERAL NOTES PART MUST BE CLEAN WITH NO SINKS FLASH SHARP EDGES OR BURRS 1 ALL DIMENSIONS ARE IN M...

Страница 6: ...om above not to scale Mounting Brackets Figure 5 Positioning the Transducer on the Vessel Hull CAUTION The above mounting example is provided as a guide WASSP Ltd recommend that a reputable boat build...

Страница 7: ...ter on the hull or inside the hull in a specially prepared cofferdam with the transducer face flush with the hull and faired to the hull shape It is important that the part of the hull in front of the...

Страница 8: ...INSTALLATION MANUAL 5 MOUNTING ASSEMBLY NOTE For the following transducers mounting parts are not included in the package 5 1 160KHZ TRANSDUCER MOUNTING x x PARTS LIST ITEM QTY PART DESCRIPTION 1 1 Tr...

Страница 9: ...1 Doc Transducer Installation Version 2 6 May 2021 wassp com wassp com TRANSDUCER INSTALLATION MANUAL TRANSDUCER INSTALLATION MANUAL 5 2 80KHZ TRANSDUCER MOUNTING ASSEMBLY All measurements are nominal...

Страница 10: ...Alexandra Oetzel Craig Shannon B C D E F A 1 8 6 7 5 4 3 2 GENERAL NOTES PART MUST BE CLEAN WITH NO SINKS FLASH SHARP EDGES OR BURRS 1 ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE SPECIFIED 2 A...

Страница 11: ...hull at the transducer mounting location 2 Cut the fairing using the measured deadrise angle The cutting guide on the fairing can be used to guide the fairing over a bandsaw table 3 Hold the fairing...

Страница 12: ...hrough the fairing and hull all the way to the washer and nut 5 Place the backing block over the gland 6 Place a washer and two nuts on the threaded rods inside the boat to secure the backing block 7...

Страница 13: ...it will not cause aeration when sealed off 5 Fill the bolt holes on the face of the transducer ensuring that they are sealed and flush consider the product s used as it will need to be removed for th...

Страница 14: ...d pipe using a spanner Tighten the lock plate until a good joint is achieved Clean excess marine sealant Lock the lock plate lock screw using an allen key 7 Feed the transducer cable through the gland...

Страница 15: ...Forcing the cable to bend twist or stretch beyond its means will damage the transducer and impair performance Once the transducer has been installed ensure that the transducer cable is not under tensi...

Страница 16: ...ducer to a DRX and your unit does not have a built in discharge port then we recommend you request an external discharge module to prevent damage to your DRX Figure 14 DRX with the Transducer Receive...

Страница 17: ...59 dB RVR 194 dB 194 dB 194 dB Cable Gland Assembly Static Pressure 6bar 6bar 6bar Require installation as per instructions in manual Table 1 Technical Specification 10 PRODUCT REGISTRATION SUPPORT AN...

Страница 18: ......

Отзывы: