Operator Manual
Ź
E:0006: High Duty Cycle (pwr %d pw %.1f ss %hu es %hu) (%s)
pwr %d => last valid power lever set
pw %.1 => last valid pulse width set
f ss %hu => last valid start slice number
es %hu => last valid end slice number
%s => module detecting error
The controller has attempted to set a combination of ping parameters which result in a duty
cycle too large for the transmit board. The ping is commanded at the last valid combination,
and and the last valid combination of parameters returned to the controller.
7.4.2 PM MESSAGES
Ź
“Ping Settings: Bad Parameter”
A decoding error occured. This implies network corruption.
Ź
³79*'DWD%DGGHIDXOW¿OH´
6XJJHVWUHVWDUWLQJVRIWZDUHDQGLISUREOHPSHUVLVWVUHLQVWDOO¿OHVFRXOGEHPLVVLQJ
Ź
“Settings Update Not Allowed”
30DSSOLFDWLRQFRQ¿JXUDWLRQKDVEHHQUHVWULFWHG7KLVVKRXOGQRWRFFXUDVLWLPSOLHV,1,¿OH
FRUUXSWLRQ5HVWRUH&OHDQWKHV\VWHPFRQ¿JXUDWLRQXVLQJWKH&RQ¿JXUDWLRQ0DQDJHU
Ź
“No Processing Module Dongle Detected”
This message will occur when the dongle that the WASSP system is reading does not have
an applicable WASSP licence. If another dongle is present, this must be removed. Insert
WASSP Dongle then press ping button.
Other messages you may see could be internal software
errors, or as yet undocumented information.