When I run WASSP, it displays an error message - what does it
mean? Is my WASSP system faulty?
Consult the list below for the cause/course of action if an error message is displayed in WASSP.
7.4.1 GUI MESSAGES
7.4.1.1 Faults
Ź
F:0002: BAD COMMS TO RECEIVER BOARD (%s)
%s => module detecting error.
The communications link between the receiver board and Mity Carrier board has experi-
enced interference. This may be in the form of noise on the data line.
The System will attempt to recover by resetting the Receiver board.
This may be accompanied by the BTxR’s LED turning orange.
Ź
F:0003: TRANSMITTER UNDER VOLTAGE SET (STATUS = %lx) (%s)
%lx => status bits from transmitter board
%s => module detecting error
This message will occur when the voltage on the transmit board has not reached the re-
quired level for a transmit ping pulse.
Is the system has been reset by another fault then the transmit board may be disabled, re-
sulting in the under voltage error.
If this error does not get cleared (see below), check the PSU max current.
Check that it is not a secondary problem due to the BTxR resetting caused by an unrelated
event.
Ź
F:0004: TRANSMITTER UNDER VOLTAGE CLR (STATUS = %lx) (%s)
%lx => status bits from transmitter board
%s => module detecting error
This is a message informing the user that the voltage of the transmit board has reached the
required level, and is no longer under-voltage.
This will only occur after the above error.
Ź
F:0007: DRIVER REFUSED TO PING: UPP NOT READY (delta %0.6fsec) (%s)
%0.6f => time since last ping attempt
%s => module detecting error
A ping has been requested from the controller before the BTxR has dealt with the current
ping.This is usually a result of a timeout, potentially because the carrier board has not re-
ceived a full ping’s worth of data, possibly due to bad ribbon cable (see F:0002).
Ź
F:0008: DRIVER REFUSED TO PING: BAD TX BOARD STATUS(delta %0.6fsec) (%s)
%0.6f => time since last ping attempt
%s => module detecting error
A ping has been requested by the controller and refused, due to bad transmit board status
(e.g. under voltage).