Doc. P/N:
WSP-009-008
Version: V1.3
Issue Date: April 2014
Operator Manual
Main Menu
7
2.5
Gain Control
The Gain Control adjusts the display gain of the received information.
Manually adjust by either clicking and then using the scroll wheel on the mouse,
or be using the mouse pointer to drag the knob clockwise to increase and
counter-clockwise to decrease.
2.6
Range Control
Adjusts the depth range of the receiver.
The numeric display is YELLOW for manual and GREEN for automatic adjustment.
Default is green (automatic mode).
Manually adjust by either clicking and then using the scroll wheel on the mouse or
by using the mouse to drag the knob clockwise to increase and counter-clockwise
to decrease. Double clicking on the number causes the control to switch from
manual to automatic and vice versa. Automatic mode is recommended.
2.7
Layout Selection
Acoustic Layout
Select
These buttons cycle through preset display layout
arrangements. Each of the Sonar displays and Chart
displays can be configured in different arrangements,
and those arrangements can be cycled through.
Left-click
to cycle
forwards
through the layouts, or
right-click
to cycle
backwards
.
See section “7.5 Layout Tab” on page 54 for information
on configuring the preset layouts.
Chart Layout
Select
2.8
Power Level Control
The transmit power level selector / indicator operates in the manual and auto modes. Initially use auto power by
signal (BLUE) until you are familiar with the operation of the unit.
Manual Mode
There are 14 transmit power levels that can be selected.
Click the increment (+) or decrement (–) buttons to
adjust between 01 to 14.
Auto Mode
Double-clicking the LED indicator selects the auto mode,
indicated by the LEDs changing to GREEN or BLUE.
GREEN automatically selects the power based on the
current depth. BLUE automatically selects the power
based on the signal level.
Consult the Power Tab of the Ship Setup Options if you
wish to change the Automatic Power settings. See “7.2.5
Power” on page 49 for more details.