Parameter
Accuracy
Resolution
Wind direction
1
± 3.0° @ ± 60° forward motion
1°
Wind speed
1
± 0.5 m/s from 2-15 m/s
0.1 m/s
Altitude
1
± 0.5 m
0.1 m
Ground speed
2
0.05 m/s
0.1 m/s
Ground bearing
2
0.3°
0.1°
Temperature
3
± 1°
1°
Relative Humidity
3
± 3 % RH
1 % RH
Atmospheric pressure
3
± 5 Pa
1 Pa
Weight
75 g excluding mount
107 g including mount
Size
120 x 55 x 60 mm
1. Tests carried out @ 20°C, 60%RH 101,325 Pa
2. GPS specifications
3. Sensor specifications
Technical Specifications
WASP WS Final. Adjusted.indd 11
12/11/18 2:49 pm