52
OPTOIO-PCIe16
ULTRA
© 2017 by Messcomp Datentechnik GmbH
DV01
52
OPTOIO-PCIe16
ULTRA
© 2017 by Messcomp Datentechnik GmbH
EV04
52
52
wasco
®
wasco
®
Register OCUNITxe:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
U
reserved
23:16
U
reserved
15:8
U
reserved
7:0
U
R/W
reserved
en
Bit 31 - 1 reserved (value 0 is written)
Bit 0
OCUNITxe<0>
(default = 0)
Start or stop OC Unit
0 = stopped (default)
1 = started (operating measurements)
Register OCTIMERx:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
OCTIMERx <31:24>
23:16
R/W
OCTIMERx <23:16>
15:8
R/W
OCTIMERx <15:8>
7:0
R/W
OCTIMERx <7:0>
Bit 31 - 0
OCTIMERx<31:0>
(default = 0)
From this register read out or write to (e.g. for the initial state) the
current value of the OC Timer x
Register OCUNITxe:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
U
reserviert
23:16
U
reserviert
15:8
U
reserviert
7:0
U
R/W
reserviert
en
Bit 31 - 1 reserviert ( mit dem Wert 0 beschreiben)
Bit 0
OCUNITxe<0>
(default = 0)
OC-Unit starten bzw. stoppen
0 = gestoppt (default)
1 = gestartet (führt Messungen durch)
Register OCTIMERx:
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
R/W
OCTIMERx <31:24>
23:16
R/W
OCTIMERx <23:16>
15:8
R/W
OCTIMERx <15:8>
7:0
R/W
OCTIMERx <7:0>
Bit 31 - 0
OCTIMERx<31:0>
(default = 0)
Aus dem Register kann der aktuelle Wert des OC-Timers x ausgele-