background image

Handbuch

wasco

®

wasco

®

user‘s guide

EXDUL-584E

EXDUL-584S

EXDUL-584E

EDV-Nr.: A-371940

EXDUL-584S

EDV-Nr.: A-371920

8 A/D-Eingänge 16 Bit (single-ended) oder

4 A/D-Eingänge 16 Bit (differentiell)

8 D/A-Ausgänge 16 Bit

1 Eingang über Optokoppler

1 Ausgang über Optokoppler

Zähler 32 Bit

LCD-Anzeige (nur EXDUL-584E)

EDP-No: A-371940

8 A/D inputs 16 bit (single ended) or

4 A/D outputs16 bit (differential)

8 D/A outputs16 bit

1 optocoupler isolated digital input

1 optocoupler isolated digital output

counter 32 bit

LCD display (EXDUL-584E only)

EDP-No: 371920

Содержание 371920

Страница 1: ...it differentiell 8 D A Ausgänge 16 Bit 1 Eingang über Optokoppler 1 Ausgang über Optokoppler Zähler 32 Bit LCD Anzeige nur EXDUL 584E EDP No A 371940 8 A D inputs 16 bit single ended or 4 A D outputs16 bit differential 8 D A outputs16 bit 1 optocoupler isolated digital input 1 optocoupler isolated digital output counter 32 bit LCD display EXDUL 584E only EDP No 371920 ...

Страница 2: ...Anzeige alle wei teren Funktionen der Module sind identisch Für das EXDUL 584S sind die Befehle und Funktionen die das Display betreffen nicht zutreffend Copyright 2018 by Messcomp Datentechnik GmbH This documentation is copyright by Messcomp Datentechnik GmbH All rights are reserved Messcomp Datentechnik GmbH reserves the right to modify the products described in this manual at any time and witho...

Страница 3: ...11 4 4 Password Protection Access Code 11 4 5 Default Setting of the Network Configuration 12 4 6 Composition and Structure of the IP Address 12 4 7 How to Change the Network Configuration 13 4 8 Configuration with Static IP Address DHCP deactivated 14 4 9 Configuration with Dynamic IP Address DHCP enabled 16 4 10 LCD Display during the Booting Process EXDUL 584E only 17 4 11 LCD Display during Op...

Страница 4: ...erial Number 34 10 2 Memory areas UserA UserB UserLCD1m und UserLCD2m 35 10 3 Display Register UserLCD line1 UserLCD line2 and LCD Contrast 35 11 Installing the Driver 36 12 Programming 37 12 1 Introduction 37 12 2 Modes of Programming 37 12 3 Programming under Windows using the NET EXDUL dll Library 37 12 4 Programming with TCP Libraries 50 12 5 Access to the Module via LabVIEW and EXDUL dll 89 1...

Страница 5: ...mpakteGehäuseerlaubtdenEinsatz als mobiles Modul am Notebook sowie als Steuermodul im Steuerungs und Maschinenbau mit einfacher Wandmontage oder unkomplizierter Montage auf DIN EN Tragschienen 1 Introduction The modules EXDUL 584E and EXDUL 584S are network compatible digital I O modules with Ethernet interface Each module features either eight ground referenced or four differential 16 bit A D inp...

Страница 6: ... GND_EXT AOUT03 AOUT05 AOUT02 AOUT04 AOUT06 2 Anschlussklemmen Vcc_EXT Anschlussklemme für externe Versorgungsspannung GND_EXT Masse Anschluss 2 1 Klemmenbelegung von CN1 1 3 5 7 9 11 13 15 17 19 21 23 AIN00 AIN02 AIN04 AIN06 ADGND AOUT00 OUT00 IN00 Zähler0 Vcc_EXT 2 4 6 8 10 12 14 16 18 20 22 24 AIN01 AIN03 AIN05 AIN07 AOUT01 AOUT07 DAGND OUT00 IN00 GND_EXT AOUT03 AOUT05 AOUT02 AOUT04 AOUT06 2 Co...

Страница 7: ...xt Vcc 10V 30V GND 5V Optokopplerausgang OUT00 IN OUT Optokopplereingang IN00 16 Bit A D Wandler AIN00 AIN07 16 Bit D A Wandler AOUT00 AOUT07 Display Zähler Controller FIFO 3 1 Block Diagram EXDUL 584E 3 System Components Fig 3 1 Block diagram EXDUL 584E 24 pin Screw Terminal Block GND Ethernet Connector ext Vcc 10V 30V GND 5V Optocoupler Output OUT00 IN OUT Optocoupler Input IN00 16 Bit A D Conve...

Страница 8: ...thernet Connector ext Vcc 10V 30V GND 5V Optokopplerausgang OUT00 IN OUT Optokopplereingang IN00 16 Bit A D Wandler AIN00 AIN07 16 Bit D A Wandler AOUT00 AOUT07 Zähler FIFO 3 2 Block Diagram EXDUL 584S Fig 3 2 Block diagram EXDUL 584S 24 pin Screw Terminal Block GND Ethernet Connector ext Vcc 10V 30V GND 5V Optocoupler Output OUT00 IN OUT Optocoupler Input IN00 16 Bit A D Converter AIN00 AIN07 16 ...

Страница 9: ... LCD Anzeige nur EXDUL 584E Matrixanzeige mit 2 Zeilen und 16 Spalten zur Darstellung von 16 Zeichen je Zeile Programmierbar zur Darstellung anwendungsspezifischer Daten oder als I O Zustandsanzeige 3 3 A D Inputs 8 inputs single ended se or 4 inputs differential diff or combined se diff software selectable Resolution 16 bit Input voltage ranges bipolar 0 63 V 1 27 V 2 55 V 5 1 V 10 2 V 20 4V diff...

Страница 10: ...DUL 584 kontinuierlich grün 1 8 4 2 Anschluss der Betriebsspannung Das EXDUL 584E EXDUL 584S benötigt für den Betrieb eine Spannungsversorgung von 10 V 30 V DC an Klemme 23 Vcc und Klemme 24 GND 4 Deployment Connection to a network or to a computer is made in an easy and con venient way via an Ethernet interface the configuration is made via any web browser An external power supply unit is require...

Страница 11: ...skennung voreingestellt Benutzerkennung admin Kennwort 11111111 Groß Kleinschreibung beachten FallsüberdieseZugangsdatenkeinZugriffmöglichist wurdedieEinstellung der Zugangskennung von Ihrem Systemadministrator geändert 4 3 Integrated Webpage of EXDUL 584E EXDUL 584S Any web or internet browser such as Mozilla Firefox Internet Explorer Safari etc can access to the web page of EXDUL 584 via a TCP I...

Страница 12: ...z und Hostteil Alle Geräte die sich im gleichen Netzwerk befinden können miteinander kommunizieren Beispiel IstderIP Adresse192 168 1 83dieSubnetzmaske255 255 0 0zugeordnet so befindet sich das Gerät im Netz 192 168 als Gerät 1 83 4 5 Default Setting of the Network Configuration In the factory setting the EXDUL 584 is set to DHCP Dynamic Host Configuration Protocol i e to dynamic IPaddress During ...

Страница 13: ...er der PC noch das EXDUL diesen bietet Für diesen Fall ist das EXDUL 584 über die zuletzt eingestellte statische IP Adresse ansprechbar Für EXDUL Neugeräte ist die IP Adresse 169 254 1 1 gültig 4 7 How to Change the Network Configuration Tochangethefactorydefaultconfigurationsettings connecttheEXDUL 584 to a local network using the enclosed standard network cable and connect the power supply 10 V ...

Страница 14: ...EXDUL 584 Konfigurationsmaske deaktiviert werden Für die KonfigurationsänderungschließenSiedasEXDUL 584wieunterKapitel4 7 Änderung der Netzwerk Konfiguration an ein LAN oder einen PC an Important Information The PC used and the connected EXDUL are to be located in the same network to be able to communicate For this purpose DHCP has to be deactivated on the computer and the first two number blocks ...

Страница 15: ...Groß Kleinschreibung egal und dem Bindestrich bestehen Bestimmte IP Adressen sind reserviert bzw haben eine Sonderfunktion wie z B 127 0 0 1 local Host 192 168 1 0 0 ist Adresse des Netzes mit 255 255 255 0 Subnetz maske Once a stable Ethernet connection is established you can access the EXDUL 584 web page via any Internet browser Upon prompting the hostname http EXDUL 584 the browser should open ...

Страница 16: ...gabe des Host Namens oder der IP Adresse des EXDUL 584 Jetzt sollte der Browser die EXDUL 584 Webpage öffnen Durch Anklicken des Buttons TCP IP Config öffnet sich die Konfigurationsmaske in der Sie wie in nachfolgender Abbildung Enable DHCP aktivieren Please consult your network administrator which IP address you may use If you use an invalid IP address the access to the module may then be impossi...

Страница 17: ...n dass das Modul initialisiert wird Sobald der Bootvorgang abgeschlossen ist erscheint in beiden Fällen je nach Einstellung ent weder die I O Statusanzeige oder die UserLCD Anzeige Important note We strongly recommend to consult your network administrator before acti vating DHCP If you want to embed several identical modules of the series EXDUL 5xx into one network the presetted hostname of each m...

Страница 18: ...n Burn zu vermeiden wechselt die Anzeige im laufenden Betrieb etwa jede Minute für ca fünf Sekunden von der I O Statusanzeige oder UserLCD Anzeige in die Infoanzeige mit der aktuellen IP Adresse 4 11 LCD Display during Operation EXDUL 584E only After having completed the boot process the display switches from infor mation display to I O status display or UserLCD display depending on the setting If...

Страница 19: ...ty_v2_xx oder höher feststellen können Sie die Webpage öffnen Falls ein Öffnen der EXDUL 584 Webpage nicht möglich ist überprüfen Sie die Netzwerkverbindung oder den eingegebenen Host Namen Nähere Informationen im Kapitel FAQ Problembehandlung 5 Accessing the EXDUL 584 As mentioned before access to the configuration set up and to the inputs and outputs of the EXDUL 584 is possible via EXDUL 584 we...

Страница 20: ...r Ausgänge das Starten Stoppen undAuslesen des Zählers das Beschreiben der User Speicherbereiche dasAuslesen der Verbindungs und Modulinformationen sowie das Verändern der Konfigurationsdaten möglich 5 2 Accessing via TCP IP Sockets Using the TCP protocol a reliable connection between the computer and the EXDUL 584 will be achieved The protocol automatically takes actions in case of data loss The ...

Страница 21: ...abe für das Programm erforderlich Das ExdulUtility_v2_xx Suchprogramm evtl Nachfolgeversion ist auf der EXDUL Software CD oder auf www wasco de zum Download bereitgestellt 5 3 How to Identify Hostname IP Address and MAC Address If you don t know neither the hostname nor the IP address or the Mac address of the EXDUL 5xx modules the search tool ExdulUtility_v2_xx or later enables you to detect thes...

Страница 22: ...chen Kanal einer single ended Messung verwendet werden muss ist aus der Tabelle 5 1 zu entnehmen AIN00 AIN01 AIN02 AIN03 AIN04 AIN05 AIN06 AIN07 COM Grafik 6 1 A D Wandler Single ended The EXDUL 584 provides 8 multiplexed single ended or 4 differential 16 bit A D input channels with programmable input voltage range When the con version is triggered the computer will transfer configuration data for...

Страница 23: ... ended Kanalauswahl 1 2 3 4 5 6 7 8 ADGND 0dez 1dez 2dez 3dez 4dez 5dez 6dez 7dez AIN00 AIN01 AIN02 AIN03 AIN04 AIN05 AIN06 AIN07 COM Grafik 6 2 1 A D Wandler differentielle Messung For example for a single ended measurement of channel 3 the positive pole of the voltage source has to be connected to AIN02 and the negative pole to ADGND The channel byte of the command then is 2dez 6 2 Differential ...

Страница 24: ...ählt werden siehe Kap 6 4 Kanal Byte Differentielle Kanalauswahl 1 2 3 4 5 6 7 8 ADGND 8dez 9dez 10dez 11dez 12dez 13dez 14dez 15dez Tabelle 6 2 A D Wandler differentielle Messung 10V AIN05 AIN06 AGND Grafik 6 2 2 Heretoo thechannelisselectedviathechannelbyteaddedtothecommand for measuring the voltage You can find the corresponding values in fol lowing table Serving as an example now the differenc...

Страница 25: ... AIN03 Grafik 6 3 Eingangsspannungsbereich Bytewert Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Tabelle 6 4 A D Wandler Eingangsspannungsbereiche 6 3 Combination of Single Ended and Differential Measurement If required the measurement methods can also be varied channel by channel as in fig 6 3 or even changed on the fly between the individual meas...

Страница 26: ...annungsbereich 20 4V gilt die maximale bzw minimale Eingangsspannung von 10 2V bzw 10 2V Nur die Differenz zwischen zwei Eingängen darf 20 4V bzw 20 4V betragen Z B AIN00 10 2V und AIN01 10 2V Vdiff 20 4V AIN00 In ADGND ADC In 10V AIN01 ADGND 10 2V Vdiff 0 6V 9 4V Grafik 6 4 2 AIN00 In ADC In 10V AIN01 10 2V Vdiff 20V 10V 10 2V Grafik 6 4 3 a Single Ended Measurement As shown in Fig 6 4 1 when mea...

Страница 27: ...l nacheinander 32 mal in 10µs Schritten abzutasten Dauer Kanalanzahl 32 10µs NachAbschluss werden die Werte abgeglichen und in µV an denAnwender zurückgeschickt Beispiel 6 5 Modes of Measurement To facilitate the application the EXDUL 584 provides several modes of measurement 6 5 1 Single voltage measurement In the single measurement upon receiving the appropriate command the module performs a mea...

Страница 28: ...odus nur mit einer Abtastrate von bis zu 20kS s zu betreiben Zudem darf in diesem Zeitraum kein EXDUL Info Register beschrieben werden In this example three channels are to be sampled e g AIN01 AIN03 AIN05 These channels are transferred along with the command and the module starts running 32 measurements of the first channel hereAIN01 As soon as the measurements of the first channel have been comp...

Страница 29: ...rhanden sein kann die A D Komponente des Moduls mittels nachträglichem Abgleich an die Umgebung angepasst werden Die benötigte Software steht auf der CD bzw im Internet zur Verfügung 6 6 Adjustment of the A D Inputs The module is calibrated at an ambient temperature of approx 20 C during the final test of our production If there are larger temperature deviations in the end application the A D comp...

Страница 30: ...Bereich bipolar 10 2V und bei der folgendenAusgabe z B 3V den Bereich bipolar 5 1V verwenden um eine höhere Auflösung zu erzielen DieZuordnungdesBereichsbyte WertesundAusgangsspannungsbereichs kann aus folgender Tabelle abgelesen werden The EXDUL 584 features a total of eight digital to analog converter DAC outputs each of which can be operated with different output voltage ranges 7 1 Output Volta...

Страница 31: ...onsspannung zwi schen Masse des Moduls und Eingang beträgt 500 Volt 8 1 Pinbelegung des Eingangsoptokopplers 8 1 Optokopplereingang 16 14 12 10 15 13 11 9 1 3 5 7 2 4 6 8 16 14 12 10 15 13 11 9 1 3 5 7 2 4 6 8 Abb 8 1 8 1 Optocoupler Input 8 1 Pin assignment of the input optocoupler Fig 8 1 The EXDUL 584 provides one input channel which is optically isolated by optocouplers The isolation voltage b...

Страница 32: ...UL 584S 2018 by Messcomp Datentechnik GmbH EV06 wasco wasco UE 1 1V 3200Ω IE Optocoupler IN00 1K6 UE Protection Diode 1K6 IN00 Fig 8 2 8 2 Eingangsbeschaltung 8 3 Eingangsstrom UE 1 1V 3200Ω IE Abb 8 2 Optokoppler IN00 1K6 UE Schutzdiode 1K6 IN00 8 2 Input Circuitry 8 3 Input Current ...

Страница 33: ...Spannung EC 0 1V Strom CE 150 mA 9 1 Pinbelegung des Ausgangsoptokopplers 9 1 Optokopplerausgang 1 2 4 3 9 3 Ausgangsbeschaltung OUT OUT Schutzdiode Optokoppler 9 1 Optically Isolated Output The EXDUL module provides one output channel which also is optically isolated by optocouplers The isolation voltage between the ground of the module the and output is 500 volts 9 2 Optocoupler specifications V...

Страница 34: ...er Zeile S N ist jeweils der Hex Wert und darüber das dazugehörige ASCII Zeichen für die Serien Nummer 1044026 dargestellt Tabelle 10 1 Register HW Kennung und Seriennummer 10 Informations LCD und Userregister 10 1 Register HW Identification and Serial Number Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 HW Identification E X D U L 5 8 4 V 1 0 1 45hex 58hex 44hex 55hex 4Chex 2Dhex 35hex 38hex 34hex 2...

Страница 35: ...en Registern UserLCD Zeile1 und UserLCD Zeile2 bleiben beimAusschalten nicht erhalten Über das Register LCD Kontrast ist der Display Kontrast einstellbar der auch beim Ausschalten erhalten bleibt Nur für EXDUL 584E zutreffend bei EXDUL 584S ohne Funktion 10 2 Memory areas UserA UserB UserLCD1m und UserLCD2m Byte 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 UserA 20hex 20hex 20hex 20hex 20hex 20hex 20hex ...

Страница 36: ...vorhandenenTCP IP Libraries benötigt Beispiele in meh reren Programmiersprachen für den Zugriff sind auf der mitgelieferten CD und auf unserer Website www messcomp com zu finden 11 Installing the Driver The Ethernet module EXDUL 584 does not require any driver Precondition is a provided network connection from the computer network interface card with driver or from a mobile device For direct acces...

Страница 37: ... EXDUL Modulen geachtet Dies ermöglicht es dem Anwender bei Bedarf ohne großen Programmieraufwand von z B einem USB EXDUL Modul auf ein Ethernet EXDUL Modul z B EXDUL 384 EXDUL 584 zu wechseln 12 Programming 12 1 Introduction You can program under Windows using the so called TCP IP sockets for which many commonly used programming languages provide standard libraries The use of Net Frameworks of Mi...

Страница 38: ...mmenfassung Beschreibt die Modul Informationsregister Lesen aus Inforegister string GetModulInfo byte type Parameter type Info Typ siehe Handbuch Rückgabewerte Gibt das Register type als string zurück Zusammenfassung Liest die Modul Information Register aus Infobereich Info Byte UserA 0 UserB 1 Hardwarekennung 3 Seriennummer 4 Infobereich Info Byte UserA 0 UserB 1 Write to Info register void SetMo...

Страница 39: ...ne 0 1 Zeile 1 2 Zeile text Bis zu 16 Zeichen langer LCD Text Zusammenfassung BeschreibtdieUserLCD Register DerParameter line legt die Zeile 0 oder 1 fest und text den Text aus 16 Zeichen Write to LCD Register UserLCD void SetUserLCD byte line string text Parameter line 0 1st line 1 2nd line text LCD text up to 16 characters long Description Writes to the UserLCD registers The parameter line deter...

Страница 40: ... LCD Kontrast fest Lesen LCD Kontrastwert ushort GetLCDContrast Rückgabewerte LCD Kontrast Zusammenfassung Liest den LCD Kontrast aus LCD Modus LCD Modus Byte IO Mode 0 User Mode 1 Read the LCD Mode byte GetLCDMode Returned values LCD Modus Description Reads the LCD mode Write the LCD Contrast Value void SetLCDContrast ushort contrast Parameter contrast Values between 0 and 4095 recommended 800 to...

Страница 41: ...sammenfassung Startet den Zähler mit der Nummer index Zähler stoppen void StopCounter byte index Parameter index Counter Index Zusammenfassung Stoppt den Zähler mit der Nummer index Read the Optocoupler outputs uint GetOptoOut Returned values State of the optocoupler outputs Description Reads the state of the optocoupler outputs Write the Optocoupler outputs void SetOptoOut uint value Parameter va...

Страница 42: ...aus Overflow Flag rücksetzen void ResetOverflowFlagCounter byte index Parameter index Counter Index Zusammenfassung Setzt das Overflowflag des Zählers mit der Nummer index zurück Reset Counter void ResetCounter byte index Parameter index Counter index Description Sets the counter reading of the counter with the number index back to 0 Read Counter uint ReadCounter byte index Parameter index Counter...

Страница 43: ...AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal AD Single Measurement int GetADC byte channel byte range Parameter channel Channel range Measurement range Returned values Measured value in µV Description Performs an ADC measurement Channel Channel byte Single Ended AIN00 0 AIN01 1 AIN02 2 AI...

Страница 44: ... AIN04 AIN05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal AD Single measurement averaging 32 measurements public int GetADC_Mean byte channel byte range Element of EXDUL EXDUL584 Parameter channel Channel range Measurement range Returned values Measured value in µV Description Performs...

Страница 45: ...N05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal AD block measurement with averaging int GetADC_BlockMean EXDUL ADC_CHANNEL_CONFIG_1 config Parameter config Returned values Measured value in µV Description Performs an ADC block measurement over several channels see manual Channel Chann...

Страница 46: ...kgesetzt ADC FIFO auslesen int ReadFIFO Rückgabewerte Gibt ein Array mit den Messwerten zurück Die Größe des Arrays ist von der Messanzahl abhängig Zusammenfassung Liest das ADC FIFO aus Reset ADC FIFO void ResetFIFO Description This command performs a reset of the FIFO This shoud be done after an overflow Read ADC FIFO Overflow flag bool ReadOverflowFlagFIFO Returned values Overflowflag false no ...

Страница 47: ...05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal AD Multiple Measurement int GetADC_Multi ushort counts uint samplerate EXDUL ADC_CHANNEL_CONFIG_1 config Parameter counts number of measurements samplerate sampling rate config channel configurations Returned values Measured value in µV D...

Страница 48: ...05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal Start AD Continuous sampling void StartADC uint samplerate EXDUL ADC_CHANNEL_CONFIG_1 config Parameter samplerate sampling rate config channel configurations Description Starts an ADC continuous sampling over one or more channels The meas...

Страница 49: ...el Ausgangskanal 0 bis 7 voltage Ausgangsspannung Zusammenfassung LegtandemDAC Kanal channel dieSpannung voltage an DieSpannungmussimeingestellten Bereich liegen DAC Ausgangsspannungsbereich bestimmen void SetDACRange byte channel byte range Parameter channel Ausgangskanal 0 bis 7 range Spannungsbereich Zusammenfassung Stellt an dem DAC Kanal channel den Bereich ein Werksreset void DefaultReset Zu...

Страница 50: ...2 4 Programming with TCP Libraries Durch die Möglichkeit mit Standard TCP Socket Libraries auf das Modul zugreifen zu können kann der Anwender mit einer Vielzahl an Sprachen seineAnwendung auf verschiedenen Platformen programmieren So kann unter Windows neben dem NET Framework auch Delphi oder Java ver wendet werden Auch können Anwendungen auf vielen Linux basierten Betriebssystemen mit z B C oder...

Страница 51: ...von der zu sendenden Datenmenge abhängig Genauere Informationen befinden sich bei den einzelnen Befehlsbeschreibungen Befehl Byte 0 Befehl Byte 1 Befehl Byte 2 Längenbyte 12 4 2 Command and Data Format Data is exchanged by transmitting and receiving byte arrays Each byte array to be transmitted or received consists of at least 4 bytes The first three bytes represent the command and the fourth byte...

Страница 52: ...lich muss das Längenbyte um den Wert 2 8Byte erhöht werden Die Rückantwort beinhaltet kein Passwort und entspricht dem normalen Antwortarray ohne Passwort 12 4 3 Password protection In order to protect the module from unauthorized access a simple pass word protection can be used for data exchange If this is activated see security configuration command the correct password 8 Bytes has to be appende...

Страница 53: ...0 09 AD Multiple measurement 0A 00 0A Start AD continuous sampling 0A 00 0B Stop AD continuous sampling 0A 80 00 Configurate DA input voltage range 0A 80 01 Output DA voltage 09 00 00 Counter0 Hexcode Beschreibung 0C 00 00 Inforegister lesen und schreiben 0C 00 03 LCD Register lesen und schreiben 0C 00 08 Netzwerkkonfigurationen lesen und schreiben 0C 00 0C Securitykonfigurationenen lesen und schr...

Страница 54: ...s ganzer 16 Byte Block beschreibbar Beispiel Schreiben der Zeichenfolge EXDUL 584 in Register UserA und UserB Infobereich Info Byte UserA 0 UserB 1 12 4 5 Structure of commands Writing into the info registers The EXDUL module provides several writable information registers UserA B are two 16 byte areas for the user to store information into a non volatile memory FLASH The registers are writable on...

Страница 55: ...angen ein 20Byte langer Block mit Inhalt von UserA bzw UserB Info Alle Infobereiche lassen sich nur als ganzer 16 Byte Block auslesen The EXDUL module provides several 16 byte wide information areas which hold module information such as serial number or Hardware identifier Additionally the user can also read out the writable user registers Byte Transmit Representing Receive Representing 0 0C Comma...

Страница 56: ...ci 16 20 Daten 13 Zeichen Leer asci 17 20 Daten 14 Zeichen Leer asci 18 20 Daten 15 Zeichen Leer asci 19 20 Daten 16 Zeichen Leer asci Example Read out information area hardware identifier An 8 byte block is transmitted and a 20 byte block is received with hardware identifier Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 Command code 2nd B...

Страница 57: ...ichen 2dez 10 36 Daten 7 Zeichen 6dez 11 reserviert 12 reserviert 13 reserviert 14 reserviert 15 reserviert 16 reserviert 17 reserviert 18 reserviert 19 reserviert Example Read out information area serial number An 8 byte block is transmitted and a 20 byte block is received with serial number Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 C...

Страница 58: ...14 Zeichen Leer asci 22 20 Daten 15 Zeichen Leer asci 23 20 Daten 16 Zeichen Leer asci Beispiel Schreiben der Zeichenfolge EXDUL 584 in Register Writing into LCD registers The EXDUL module provides several writable LCD registers UserLCD1 and UserLCD2 correspond to the two lines when using UserMode LCD display UserLCD1m and UserLCD2m are two 16 byte wide areas which are stored directly to a non vol...

Страница 59: ...lstart in die Register UserLCD1m bzw UserLCD2mgeladenwerden AlleRegistersindnuralsganze16 Byte Blöcke lesbar LCD Befehl LCD Befehl Byte UserLCD1 UserLCD2 0 UserLCD1m UserLCD2m 2 Reading from LCD registers The EXDUL module provides several writable and readable LCD regi sters UserLCD1 and UserLCD2 correspond to the two lines when using UserMode LCD display UserLCD1m and UserLCD2m are two 16 byte ar...

Страница 60: ...i 33 20 Daten Zeile2 14 Zeichen Leer asci 34 20 Daten Zeile2 15 Zeichen Leer asci 35 20 Daten Zeile2 16 Zeichen Leer asci Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 03 Command code 3rd Byte 03 Command code 3rd Byte 3 01 Length byte 20 Byte 08 Length byte 20 Byte 4 00 UserLCD1 2 02 UserLCD...

Страница 61: ... 8 Byte 00 Längenbyte 0 Byte 4 04 LCD Befehl LCD Mode 5 00 reserviert 6 00 reserviert 7 00 Schreibfunktion 8 00 IO Mode 01 User Mode LCD Modus 9 00 reserviert 10 00 reserviert 11 00 reserviert Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 03 Command code 3rd Byte 03 Command code 3rd Byte 3 0...

Страница 62: ...ellt mehrere Anzeige Modi bereit Der eingestellte LCD Modus kann mit folgendem Befehl ausgelesen werden Beispiel Lesen des LCD Modes LCD Modus LCD Modus Byte IO Mode 0 User Mode 1 Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 03 Command code 3rd Byte 03 Command code 3rd Byte 3 01 Length byte...

Страница 63: ...hl LCD Kontrast 5 00 reserviert 6 00 reserviert 7 00 Schreibfunktion 8 50 Kontrastwert Lowbyte 00 FF 9 03 Kontrastwert Highbyte 00 0F 10 00 reserviert 11 00 reserviert Byte Transmit Representing Receive Representing 0 0C Command code 1st Byte 0C Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 03 Command code 3rd Byte 03 Command code 3rd Byte 3 02 Length byte 8 Byte 00 L...

Страница 64: ...lwert 63 25 0 IP Adresse 3 Byte Dezimalwert 0 26 A8 IP Adresse 2 Byte Dezimalwert 168 27 C0 IP Adresse 1 Byte Dezimalwert 192 Writing the network configuration This command is used to modify all of the network configurations such as IP address subnet mask hostname Gateway DNS addresses and the setting of the DHCP client function Byte Transmit Representing Receive Representing 0 0C Command code 1st...

Страница 65: ...ary DNS 1 Byte Dezimalwert 217 44 0w 00 DHCP disable 01 DHCP enable DCHP Client konfiguration 45 00 reserviert 46 00 reserviert 47 00 reserviert 28 00 4th Byte Subnetmask decimal value 0 29 FF 3rd Byte Subnetmask decimal value 255 30 FF 2nd Byte Subnetmask decimal value 255 31 FF 1st Byte Subnetmask decimal value 255 32 01 Gateway 4th Byte decimal value 1 33 00 Gateway 3rd Byte decimal value 0 34 ...

Страница 66: ...bnetmaske 3 Byte Dezimalwert 255 26 FF Subnetmaske 2 Byte Dezimalwert 255 27 FF Subnetmaske 1 Byte Dezimalwert 255 Reading the network configuration This command is used to read all of the network configurations such as IP address subnet mask hostname Gateway DNS addresses and the setting of the DHCP client function or MAC address Byte Transmit Representing Receive Representing 0 0C Command code 1...

Страница 67: ... 47 00 MAC Adresse 5 Zeichen 48 00 MAC Adresse 4 Zeichen 49 3E MAC Adresse 3 Zeichen 50 B4 MAC Adresse 2 Zeichen 51 D4 MAC Adresse 1 Zeichen 28 01 Gateway 4th Byte decimal value 1 29 00 Gateway 3rd Byte decimal value 0 30 A8 Gateway 2nd Byte decimal value 168 31 C0 Gateway 1th Byte decimal value 192 32 01 Primary DNS 4th Byte decimal value 1 33 00 Primary DNS 3rd Byte decimal value 0 34 A8 Primary...

Страница 68: ... gesendet werden Im Default Zustand ist dieser deaktiviert Beispiel Schreiben der Securitykonfiguration Securitykonfiguration Security Byte Passwort deaktiviert 0 Passwort aktiviert 1 Byte Transmit Receive Representing 0 0C 0C Command code 1st Byte 1 00 00 Command code 2nd Byte 2 0C 0C Command code 3rd Byte 3 01 01 Length byte 20 Byte 4 00 Password deactivated 01 Password activated Security Byte 5...

Страница 69: ... gesendet werden Im Default Zustand ist dieser deaktiviert Beispiel Lesen der Securitykonfiguration Securitykonfiguration Security Byte Passwort deaktiviert 0 Passwort aktiviert 1 Byte Transmit Receive Representing 0 0C 0C Command code 1st Byte 1 00 00 Command code 2nd Byte 2 0C 0C Command code 3rd Byte 3 01 01 Length byte 20 Byte 4 00 00 Password deactivated 01 Password activated Security Byte 5 ...

Страница 70: ... 5 Zeichen Lasci 9 35hex Passwort 6 Zeichen 5asci 10 38hex Passwort 7 Zeichen 8asci 11 34hex Passwort 8 Zeichen 4asci Beispiel Ändern des Passwortes in EXDUL584 Changing the Access Code Password The EXDUL module features a password protection for secure com munication If this is activated each transfer to the module requires the correct password In default state the password is 11111111 in ASCII a...

Страница 71: ...t Optokopplerzustand 6 00 reserviert 7 00 reserviert Beispiel Ausgabe eines Zustands am Optokopplerausgang Gesendet wird ein 8Byte langer Block und empfangen ein 4Byte Block als Bestätigung Reading the Optocoupler Output Port This command is used to read the current state of the optocoupler output Example reading the optocoupler output state An 8 byte block is transmitted and an 8 byte block is re...

Страница 72: ...low Flag einzulesen und rückzusetzen Code Zähler Befehlscode 00 Zähler starten 01 Zähler stoppen 02 Zähler resetten 03 Zählerstand lesen 04 reserviert 05 Overflow Flag lesen 06 Overflow Flag rücksetzen Reading the Optocoupler Input Port This command is used to read the current state of the optocoupler input Example reading the optocoupler input state An 4 byte block is transmitted and an 8 byte bl...

Страница 73: ...erstand Byte2 11 ww Zählerstand Byte3 Zählerstand Zählerstand Byte3 0x1000000 Zählerstand Byte2 0x10000 Zähler stand Byte1 0x100 Zählerstand Byte0 Byte Transmit Representing Receive Representing 0 09 Command code 1st Byte 09 Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 00 Command code 3rd Byte 00 Command code 3rd Byte 3 01 Length byte 01 Length byte 4 bb 00 01 02 Cou...

Страница 74: ...lag rücksetzen 06 Zähler Befehlscode Overflow Flag rücksetzen 5 00 reserviert 00 reserviert 6 00 reserviert 00 reserviert 7 00 reserviert 00 reserviert Reading the overflow flag Byte Transmit Representing Receive Representing 0 09 Command code 1st Byte 09 Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 00 Command code 3rd Byte 00 Command code 3rd Byte 3 01 Length byte 0...

Страница 75: ...1 4Byte 01 4Byte Längenbyte 4 cc Kanalbyte ww Messwert Byte0 5 bb Bereichbyte ww Messwert Byte1 6 00 ww Messwert Byte2 7 00 ww Messwert Byte3 AD Single measurement The command AD single measurement performs a voltage measure ment on a desired analog input channel and returns the value calibrated as an integer in µV to the computer The desired channel as well as the measuring range are to be transf...

Страница 76: ...te 01 4Byte Längenbyte 4 cc Kanalbyte ww Messwert Byte0 5 bb Bereichbyte ww Messwert Byte1 6 00 reserviert ww Messwert Byte2 7 00 reserviert ww Messwert Byte3 AD Single measurement with averaging The command single measurement with averaging performs 32 voltage measurements on a desired analog input channel at a sampling rate of 100kS s averages the value and returns it calibrated as an integer in...

Страница 77: ... w1w1 Messwert1 Byte31 3 n 4 wnwn Messwertn Byte0n 4 n 4 1 wnwn Messwertn Byte1n 4 n 4 2 wnwn Messwertn Byte2n 4 n 4 3 wnwn Messwertn Byte3n AD block measurement with averaging This command performs sampling of up to 8 channels in quick succession Each channel to be measured is sampled 32 times each averaged see chapter 5 2 and the value returned as an integer in µV to the computer Channel Channel...

Страница 78: ...0x1000000 Byte22 0x10000 Byte12 0x100 Byte02 µV Messwert AIN04 integer Byte33 0x1000000 Byte23 0x10000 Byte13 0x100 Byte03 µV Byte Transmit Representing Receive Representing 0 0A Command code 1st Byte 0A Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 02 Command code 3rd Byte 02 Command code 3rd Byte 3 03 12Byte Length byte 03 12Byte Length byte 4 00 reserved w1w1 Measu...

Страница 79: ...te 3 00 Längenbyte 01 Längenbyte 4 Bytes 4 0w Overflowflag 00 FIFO nicht übergelaufen 01 FIFO übergelaufen 5 00 reserviert 6 00 reserviert 7 00 reserviert Reset of the ADC FIFO The following command is used to reset of the ADC FIFO This should be done after an overflow Byte Transmit Representing Receive Representing 0 0A Command code 1st Byte 0A Command code 1st Byte 1 00 Command code 2nd Byte 00 ...

Страница 80: ...swert1 Byte31 n 4 wwn Messwertn Byte0n n 4 1 wwn Messwertn Byte1n n 4 2 wwn Messwertn Byte2n n 4 3 wwn Messwertn Byte3n Read out the ADC FIFO Some commands do not return the measurement results directly along with the response command but store the measured values into a FIFO As a command example multiple measurement or continuous measure ment can be mentioned The FIFO can be read out with the ADC...

Страница 81: ...ww2 Messwert2 Byte02 9 ww2 Messwert2 Byte12 10 ww2 Messwert2 Byte22 11 ww2 Messwert2 Byte32 Beispiel 2 Im FIFO sind zwei Messwerte vorhanden Byte Transmit Representing Receive Representing 0 0A Command code 1st Byte 0A Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 08 Command code 3rd Byte 08 Command code 3rd Byte 3 00 Length byte 00 Length byte Example 1 FIFO is empty...

Страница 82: ...en Befehl Längenbyte nein ja Längenbyte 0 Es sind 4 Längenbyte Bytes im Empfangsbuffer ja nein nein FIFO ist leer 4 Längenbyte Bytes auslesen Empfangsroutine beendet ja Programming Transmitting a 4 byte holding command is to be sent to the module in order to read out data from the FIFO Receivingthedata sincethearraylengthofthedatatobereceivedmay vary the reception of the entire data block has to b...

Страница 83: ...N04 AIN05 12 AIN04 AIN05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal AD Multiple Measurement The A D multiple measurement allows the user to sample one or more channels several times up to 65 535 times in an adjustable clock 1 100000kHz The measured values are stored by the module int...

Страница 84: ... 00 reserviert n 4 9 00 reserviert n 4 10 ccn Kanalbyten n 4 11 bbn Bereichsbyten Abtastrate Byte2 65536 Byte1 256 Byte0 Messanzahl Byte1 256 Byte0 Command structure n 1 8 Byte Transmit Representing Receive Representing 0 0A Command code 1st Byte 0A Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 09 Command code 3rd Byte 09 Command code 3rd Byte 3 n 2 Length byte 00 Len...

Страница 85: ...IN04 AIN05 12 AIN04 AIN05 13 AIN06 AIN07 14 AIN06 AIN07 15 Messbereich Bereichsbyte Spannung 0 20 4V nur bei Differenzmessung max 10 2V GND 1 10 2V 2 5 1V 3 2 55V 4 1 27V 5 0 63V Kanal Start AD continuous measurement The A D continuous measurement allows the user to sample one or more channels at regular intervals 1s 10µs The measured values are stored by the module into the internal FIFO and can ...

Страница 86: ... 1 Byte 0A Befehlscode 1 Byte 1 00 Befehlscode 2 Byte 00 Befehlscode 2 Byte 2 0B Befehlscode 3 Byte 0B Befehlscode 3 Byte 3 00 Längenbyte 00 Längenbyte Command structure n 1 8 Byte Transmit Meaning Receive Meaning 0 0A Command code 1st Byte 0A Command code 1st Byte 1 00 Command code 2nd Byte 00 Command code 2nd Byte 2 0A Command code 3rd Byte 0A Command code 3rd Byte 3 n 1 Length byte 00 Length by...

Страница 87: ... 80 Befehlscode 2 Byte 80 Befehlscode 2 Byte 2 00 Befehlscode 3 Byte 00 Befehlscode 3 Byte 3 01 Längenbyte 00 Längenbyte 4 cc Kanalbyte 0 7 5 bb Bereichsbyte 6 00 reserviert 7 00 reserviert Configuration of the D A output voltage range This command is use to configurate the output voltage ranges of each single DAC channels The new voltage range of a channel is applied as soon as a new voltage is o...

Страница 88: ... 00 reserviert 7 00 reserviert 8 ww Spannung Byte0 9 ww Spannung Byte1 10 ww Spannung Byte2 11 ww Spannung Byte3 Spannung integer Byte3 0x1000000 Byte2 0x10000 Byte1 0x100 Byte0 µV DA Voltage output This command is used to output a desired voltage to one of the availa ble channels The command on one hand holds a 4 byte block for the channel to be changed and on the other hand the voltage in µV Byt...

Страница 89: ...n LabVIEW und der EXDUL dll Datei wird zudem auf dem Rechner das NET Framework benötigt Für genauere Informationen lesen Sie sich bitte das EXDUL LabVIEW Tutorial durch 12 5 Access to the Module via LabVIEW and EXDUL dll Due to the EXDUL dll the module can be integrated into a LABView project without much effort Along with the NET Framework additionally LABView and the EXDUL dll file is required o...

Страница 90: ...genzwischenEXDUL 584undderWand Netzwerkbuchse dem aktiven Ethernet Switch oder Ethernet Hub 1 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 DUL Vcc 10 24V 13 FAQ Trouble Shooting Following you can find a short compilation of the most common causes of failure that may appear during commissioning or when accessing the EXDUL 584 or to the EXDUL web page At first please check follow...

Страница 91: ...chnittstelle des Computers aktiviert Im BIOS des PCs muss der Ethernetadapter aktiviert sein Kontrollieren Sie im Windows Geräte Manager ob dieser unter Netzwerkadapter gelistet ist Der Eintrag darf nicht mit einem Ausrufezeichen versehen sein Is there a stable Ethernet connection between PC and network Check the network cable between EXDUL 584 and the network socket RJ45 wall outlet the active Et...

Страница 92: ...se für das EXDUL 584 lautet 192 168 1 199 Netzwerk ID 192 168 1 Geräte ID 199 Für den Zugriff auf das EXDUL 584mussderverwendetePCaufdieSubnetzmaske255 255 255 0 und auf eine statische IP Adresse im Bereich zwischen 192 168 1 1 und 192 168 1 244 eingestellt sein Are the computer s network settings correct Each active device in aTCP IPbased network requires a unique IPaddress which is structured in...

Страница 93: ... prompt see How to switch to MS DOS prompt type ipconfig and press enter to confirm The response should look similar to the following figure Wie kann die Netzwerkeinstellung des PCs überprüft werden Die TCP IP Einstellungen Ihres Rechners können Sie über das Fenster Eigenschaften von Internetprotokoll Version 4 TCP IPv4 bzw Status von LAN Verbindung siehe WiekanndieIP AdressedesPCsüberprüftundgeän...

Страница 94: ...rbindung auswählen Doppelklick oder rechte Maustaste Eigenschaften Internetprotokoll TCP IP Eigenschaften Hinweis Zum Ändern der TCP IP Einstellungen sind Administratorrechte notwendig How to check and to change IP address of the PC Windows7 Start Control Panel Network Connections monitoring network status and tasks change adapter settings select required LAN connection in the window network conne...

Страница 95: ... PC ange schlossenes EXDUL 5xx wie für ein Netzwerk über Hub oder Switch mit mehreren Modulen Für das Programm ist eine Freigabe in Ihrer Firewall erforderlich falls diese die Kommunikation des Suchprogrammes mit den EXDUL 5xx verhindert How to switch to MS DOS prompt Windows7 Start type in cmd in input box program and file searching press enter to confirm or Start All Programs Accessories prompt ...

Страница 96: ...reich high 10 30 Volt low 0 3 Volt Digitaler Ausgang über Optokoppler 1 Kanal einzeln galvanisch getrennt Leistungsoptokoppler Verpolungsschutz Dioden Ausgangsstrom max 150 mA Spannung CE max 50 V 14 Specifications A D Inputs 8 inputs single ended se or 4 inputs differential diff or combined se diff software sectable Resolution 16 Bit Input voltage range bipolar 0 63 Volt 1 27 Volt 2 55 Volt 5 1 V...

Страница 97: ...egrated snap in technology for DIN EN top hat rail mounting Suitable for control and engineering technology mounted to control and distribution boxes surface mounting or mobile use on a desk Betriebsspannung externe Spannungsversorgung notwendig 10 V 30 V Ethernet Schnittstelle 100Base T Ethernet Interface Modul Anschlüsse 1 24polige Schraubklemmleiste Ethernet RJ45 Buchse Ethernet Anschlussleitun...

Страница 98: ...haltung des Optokoppler Eingangs Grafik 15 1 Beschaltung des Optokopplereingangs EXDUL 584 24V VEXT GNDEXT IN00 A K C E Schalter Schalter offen 0 Schalter geschlossen 1 Prinzipschaltbild IN00 15 1 Wiring of the Optocoupler Input EXDUL 584 24V VEXT GNDEXT IN00 A K C E Principle circuit diagram IN00 Circuit breaker open 0 Circuit breaker closed 1 Circuit breaker Figure 15 1 Optocoupler input wiring ...

Страница 99: ...ptokoppler Ausgangs Grafik 15 2 Beschaltung des Optokoppler Ausgangs EXDUL 584 OUT00 A K C E Verbraucher z B Lampe Relais Aktor A C 24V VEXT GNDEXT Prinzipschaltbild OUT00 15 2 Wiring of the Optocoupler Output EXDUL 584 OUT00 A K C E A C 24V VEXT GNDEXT Principle circuit diagram OUT00 Electrical loads e g lamp relays actuator Figure 15 2 Optocoupler output wiring ...

Страница 100: ...usgänge Grafik 15 3 Beschaltung der DA Ausgänge AOUT00 AOUT01 Intern Extern ADGND Anschlussklemmen 9 10 18 DAC1 DAC2 Verbraucher Verbraucher max 5mA max 5mA DAC8 AOUT07 16 15 3 Wiring of the D A Outputs Figure 15 3 Wiring of the D A outputs AOUT00 AOUT01 Internal External ADGND Connection Terminal 9 10 18 DAC1 DAC2 Electr Load Electr Load max 5mA max 5mA DAC8 AOUT07 16 ...

Страница 101: ...ed Grafik 15 4 Beschaltung der AD Eingänge Single ended AIN00 AIN07 AIN01 Intern Extern ADGND Multiplexer und Bereichs auswahl Anschlussklemmen 1 2 17 unbeschaltete Kanäle ADC 15 4 Wiring of the A D Inputs single ended Figure 15 4 Wiring of the A D inputs single ended AIN00 AIN07 AIN01 Internal External ADGND Multiplexer and Range Selection Connection Terminal 1 2 17 unwired Channels ADC ...

Страница 102: ...r AD Eingänge differentiell ADC AIN00 AIN06 AIN02 Intern Extern Multiplexer und Bereichs auswahl Anschlussbuchse CN1 AIN01 AIN07 AIN03 ADGND unbeschaltete Eingänge 1 3 2 4 17 R R ADC AIN00 AIN06 AIN02 Internal External Multiplexer and Range Selection Connection socket CN1 AIN01 AIN07 AIN03 ADGND unwired inputs 1 3 2 4 17 R R 15 5 Wiring of the A D Inputs differential Figure 15 5 Wiring of the A D ...

Страница 103: ...D 29 00011101 1E 30 00011110 1F 31 00011111 20 32 00100000 Leer 21 33 00100001 22 34 00100010 23 35 00100011 24 36 00100100 25 37 00100101 26 38 00100110 27 39 00100111 16 ASCII Tabelle Hex Dec Binary Character 28 40 00101000 29 41 00101001 2A 42 00101010 2B 43 00101011 2C 44 00101100 2D 45 00101101 2E 46 00101110 2F 47 00101111 30 48 00110000 0 31 49 00110001 1 32 50 00110010 2 33 51 00110011 3 3...

Страница 104: ... 10011101 9E 158 10011110 9F 159 10011111 A0 160 10100000 A1 161 10100001 A2 162 10100010 A3 163 10100011 A4 164 10100100 A5 165 10100101 A6 166 10100110 A7 167 10100111 Hex Dec Binary Character 50 80 01010000 P 51 81 01010001 Q 52 82 01010010 R 53 83 01010011 S 54 84 01010100 T 55 85 01010101 U 56 86 01010110 V 57 87 01010111 W 58 88 01011000 X 59 89 01011001 Y 5A 90 01011010 Z 5B 91 01011011 5C ...

Страница 105: ... 11110101 F6 246 11110110 F7 247 11110111 F8 248 11111000 F9 249 11111001 FA 250 11111010 FB 251 11111011 FC 252 11111100 FD 253 11111101 FE 254 11111110 FF 255 11111111 Hex Dec Binary Character A8 168 10101000 A9 169 10101001 AA 170 10101010 AB 171 10101011 AC 172 10101100 AD 173 10101101 AE 174 10101110 AF 175 10101111 B0 176 10110000 B1 177 10110001 B2 178 10110010 B3 179 10110011 B4 180 101101...

Страница 106: ...n VDE Vorschriften beachtet werden Besonders sei auf folgende Vorschriften hingewiesen VDE0100 VDE0550 0551 VDE0700 VDE0711 VDE0860 Sie erhalten VDE Vorschriften beim vde Verlag GmbH Bismarckstraße 33 10625 Berlin 17 Produkthaftungsgesetz 17 Product Liability Act Information for Product Liability The Product Liability Act Act on Liability for Defective Products Prod HaftG in Germany regulates the ...

Страница 107: ...schen Kennwerte für ein Bauteil gelten so muss stets ein Fachmann um Aus kunft ersucht werden Im Übrigen unterliegt die Einhaltung von Bau und Sicherheitsvorschriften aller Art VDE TÜV Berufsgenossenschaften usw dem Anwender Käu fer pull the mains plug before you open the unit or make sure there is no current to in the unit You only may put into operation any components boards or devices if they h...

Страница 108: ...r den Hersteller Messcomp Datentechnik GmbH Neudecker Str 11 83512 Wasserburg abgegeben durch Dipl Ing FH Hans Schnellhammer Wasserburg 31 01 2018 ________________________________ 18 CE Declaration of Conformity This is to certify that the products EXDUL 584E EDP Number A 371940 EXDUL 584S EDP Number A 371920 comply with the requirements of the relevant EC directives This decla ration will lose it...

Страница 109: ...e Zusatzelektronik 519 112111C Motherboard GA 586HX PIV 1 55 Floppy Controller auf Motherboard Floppy TEAC FD 235HF Grafikkarte Advantech PCA 6443 Schnittstellen EXDUL 584E A 371940 EXDUL 584S A 371920 Reference system for intended use The multi functional modules EXDUL 584E and EXDUL 584S are not stand alone devices The CE conformity only can be assessed when using additional computer components ...