background image

 

 

MODEL

 

2000i

 

2500i

 

3500i

 

 

G

E

N

E

R

A

TO

R

 

Type

 

Inverter Generator

 

 

AC Voltage

 

50Hz

 

100, 230V, 240V

 

60Hz

 

100, 120V, 240V

 

Max. Output

 

2.0 kVA

 

2.5 kVA

 

3.5 kVA

 

Rated Output

 

1.8 kVA

 

2.2 kVA

 

3.0 kVA

 

Power Factor

 

1.0

 

DC Output

 

12V / 8.3A

 

 

E

N

G

IN

E

 

Model

 

XY152F-3

 

XY152F-3

 

XY157F

 

Type

 

Air-cooled, 4 cycle, OHC, Gasoline Engine

 

Bore

 

Stroke 

mm 

mm

 

52.4

×

57.8

 

52.4

×

57.8

 

57.4

×

57.8

 

Displacement

 

124.6cc

 

124.6cc

 

149.5cc

 

Max. Output

 

3.5KW / 5500rpm

 

3.5KW / 5500rpm

 

4.0KW / 5500rpm

 

Fuel

 

Regular Automobile Gasoline

 

Fuel tank Capacity

 

5.7 litres

 

 

 

Rated Continuous Operation

 

4h30min

100% 

Load

) 

5h50min 

50%  Load

 

4h10min

100% 

Load

) 

5h30min 

50%  Load

 

3h5min

100% 

Load

) 

4h10min 

50%  Load

 

Lubricating oil

 

SAE 10W30

 

Lubricating oil Capacity

 

0.9 litres

 

Starting System

 

Recoil Starter

 

Ignition system

 

C.D.I.

 

Spark Plug: Type

 

A7RTC or CR5HSB (NGK)

 

 

D

IM

E

N

S

IO

N

 

Net dimension 

L

×

W

×

H

 

565

×

320

×

470

 

Overall dimension    L

×

W

×

H

 

595

×

355

×

510

 

Net Weight

 

28 Kg

 

28 Kg

 

29 Kg

 

Dry Weight

 

30 Kg

 

31Kg

 

32 Kg

 

  Specifications subject to change without prior notice. 

 

 
 
 
 

Содержание DIG1500

Страница 1: ...Brand Name Warrior Generator Name and address of technical documentation holder The technical documentation required to demonstrate that the product meets the requirements of directive has been compil...

Страница 2: ...900W Inverter Generator DIG1500 Always read the instruction manual Retain for future use...

Страница 3: ...is adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable...

Страница 4: ...or touch with wet hands Check the fuel system periodically for leaks seals and hoses should be checked for signs of deterioration or chafing Check for loose or missing clamps damaged fuel tank or fil...

Страница 5: ...match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body...

Страница 6: ...sures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to ope...

Страница 7: ...NK VENT TAP 3PARK PLUG MAINTENANCE COVER XHAUST CHARGING LEADS 3CREWDRIVER 3PARK PLUG SPANNER 4ECHNICAL SPECIFICATION OUTPUT 6 Z 2ATED POWER K6 0EAK POWER K6 0 2ATED CURRENT HASE 3INGLE 0OWER FACTOR C...

Страница 8: ...NG A WIRE AND A SMALL EARTH STAKE OTE 4HE WIRE AND EARTH STAKE ARE NOT SUPPLIED WITH THE UNIT ARTH SPIKE AND CABLE CAN BE PURCHASED AT YOUR LOCAL CAMPING SUPPLIES OR ALTERNATIVELY AN EARTH SPIKE CAN B...

Страница 9: ...s engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life Warning Never use stale or contaminated gasoline o...

Страница 10: ...NG PLATE NSURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER AND THAT THE MAINS SUPPLY LEAD IS LONG ENOUGH TO REACH THE GENERATOR WITHOUT ANY STRAIN 7HEN THE GENERATOR ENGINE HAS BEEN SU...

Страница 11: ...ELPS IN FUEL ECONOMY AND REDUCED NOISE LEVELS WHEN UNDER NO LOAD CONDITIONS 7HEN A LOAD IS CONNECTED TO THE GENERATOR THE GENERATOR SPEED WILL AUTOMATICALLY ADJUST IN ORDER TO SUPPLY ENOUGH POWER PPLI...

Страница 12: ...SIMULTANEOUSLY 4HIS IS NORMAL THE 2ED OVER LOAD INDICATOR EXTINGUISHES AFTER ABOUT FOUR SECONDS F THE 2ED OVERLOAD INDICATOR REMAINS ILLUMINATED CONSULT YOUR GENERATOR DEALER AUTION 3UBSTANTIAL OVERLO...

Страница 13: ...er the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a...

Страница 14: ...lter thoroughly using an environmentally friendly water based degreasing agent and re fit Air Filter A dirty air cleaner will restrict air flow to the carburettor To prevent carburettor malfunction se...

Страница 15: ...rom the fuel tank and the carburettor ensure that all the fuel has been removed Remove the spark plug and pour approximately one tablespoon full of clean engine oil into the spark plug hole With the i...

Страница 16: ...15 TROUBLESHOOTING...

Страница 17: ...TROUBLESHOOTING 16...

Страница 18: ...ling Check fan damage system Starting Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required Th...

Страница 19: ...sposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropriate wast...

Страница 20: ...ECYCLE WHERE FACILITIES EXIST HECK WITH YOUR OCAL UTHORITY OR RETAILER FOR RECYCLING ADVICE ENERAL WARNING 7EAR HEARING PROTECTION 7EAR EYE PROTECTION 7EAR RESPIRATORY PROTECTION 54 4HIS IS A STROKE E...

Страница 21: ...x mm 47 41 5 Displacement 72cc Max Output 2 1KW 5500rpm Fuel Regular Automobile Gasoline Fuel tank Capacity 3 6 litres Rated Continuous Operation 4 3hr 4 3hr 4 0hr Lubricating oil SAE 10W30 Lubricati...

Страница 22: ...5cc Max Output 3 5KW 5500rpm 3 5KW 5500rpm 4 0KW 5500rpm Fuel Regular Automobile Gasoline Fuel tank Capacity 5 7 litres Rated Continuous Operation 4h30min 100 Load 5h50min 50 Load 4h10min 100 Load 5h...

Страница 23: ...Stepping motor BL BL Main BL BL BL R BL BL R R BL AC SOCKET R DC SOCKET Y G Winding Control winding R R BL BL W BL W BL Oil sensor Invert cell BL O BL BL R BL BR GR BU Y G O W BU P Economic switch PI...

Страница 24: ...ng Control winding R R O O BL W PI BL BU BU BL BL BL BL R R BL BL W BL W BL Oil sensor BL R BL BL R Invert cell BL O BL BL R R BL BR GR BU Y G O W BU P R BL Economic switch PILOT OVERLOAD LOW OIL Engi...

Отзывы: