5 April 2019

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

………….

Copyright © 

 

3

 

Freestanding 
Square Twin firebox

 

 

 

SI 780 

 

FST

 

SI 780T

 

FST

 

SI 900

 

FST

 

SI 1100

 

FST

 

Firebox Width 

A

 

780

 

780

 

900

 

1100

 

Firebox Height 

B

 

600

 

680

 

750

 

800

 

Firebox Depth 

C

 

710

 

710

 

860

 

910

 

Flange Width 

D

 

830

 

830

 

950

 

1150

 

Flange Height 

E

 

625

 

705

 

775

 

825

 

Adaptor Height 

F

 

205

 

205

 

275

 

275

 

Cabinet Height 

G

 

850

 

930

 

1060

 

1110

 

Cabinet Depth 

H

 

698

 

698

 

848

 

898

 

Cabinet Width 

I

 

830

 

830

 

950

 

1150

 

Cabinet Front Height 

J

 

625

 

705

 

775

 

825

 

Flue 

K

 

300

 

300

 

325

 

350

 

Inner Baffle 

L

 

350

 

350

 

375

 

400

 

Outer Liner 

 

400

 

400

 

425

 

450

 

Heat Output

 

kW

 

  

 

  

  

Peak*

 

 

 

24

 

26

 

32

 

35

 

Range*

 

 

 

15

-

17

 

17

-

19

 

18

-

21

 

19

-

22

 

*Estimated unless stated otherwise.

 

WARMINGTON FIREBOX DIMENSION

 

Minimum flue height

 

 

 

flue height

 

4800

 

measured from top of adaptor

 

B + F + 4800

 

FIREBOX FREESTANDING TAPER TOP CABINET

 

Adaptor fitting

 

    Seal adaptor to firebox using high-temp gasket sealant. Bolt  
     through holes provided.

 

Seismic Restraint

 

Secure firebox through anchor positions provided.

 

Assembly Check List

 

 

Tick Box

 

Firebox

 

 

 

Freestanding cabinet

 

 

Adaptor (fastenings)

 

 

 

Ash Pan

 

 

 

Bricks

 

 

 

Louvres

 

 

 

Badge

 

 

 

Damper handle

 

 

 

Specifications

 

 

Packed By

 

 

 

Freestanding

 

Taper Top Cabinet

 

Seismic 

 

restraint

 

located under 

bricks

 

Содержание SI 780 FST

Страница 1: ...d current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www home...

Страница 2: ...the land in relation to the home has a bearing on how the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to max...

Страница 3: ...950 1150 Cabinet Front Height J 625 705 775 825 Flue K 300 300 325 350 Inner Baffle L 350 350 375 400 Outer Liner 400 400 425 450 Heat Output kW Peak 24 26 32 35 Range 15 17 17 19 18 21 19 22 Estimate...

Страница 4: ...and plinth details 3 Fit the firebox cabinet into position Remove the cabinet top bolt the firebox to the plinth or through to the floor with the bolting points provided on the left and right hand si...

Страница 5: ...e place Caitec weir vent system as close to fireplace as possible CAITEC TECHONOLGY ROOM AIR REPLACEMENT Caitec draws air from an external air source to ensure that combustion air the open fire uses i...

Страница 6: ...335 Hearth Depth O 1910 1910 2060 2110 Hearth Width P 1200 1200 1350 1550 Hearth Projection Q 600 600 600 600 PLAN VIEW OF CABINET CLEARANCES STRAIGHT WALL HEARTH Adaptor fitment Seal adaptor to fireb...

Страница 7: ...1 4 9 1 6 NOTE The last length of flue pipe needs to extend past the liner so that when the top spide and flashing cone are fitted the flashing cone and the flue pipe are flush or that the flue pipe i...

Страница 8: ...ng Butynol Dek tite an additional flue pipe baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 All extern...

Страница 9: ...9 CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note...

Страница 10: ...Dimension are in mm Copyright 10 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue exit is to c...

Страница 11: ...n mm Copyright 11 RAISED HEARTH CLEARANCES Note A minimum height must be maintained from the top of the cabinet to the ceiling See page 8 SI 780 1100 RAISED HEARTH CLEARANCES Note For combustible floo...

Страница 12: ...NGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO...

Отзывы: