Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

………….

Copyright © 

 

12

 

GENERAL NOTES : ASNZS 2918 : 2001

 

NOTES:

 

 

• 

Fire Operation and Maintenance Instructions can be downloaded from 

www.warmington.co.nz.

 

 

• 

Warranty 

-

 for full details on product warranties, contact your local Authorised Warmington Retailer.

 

 

• 

Correct installation, operation and maintenance must be maintained to comply with Warmington Warranty.

 

 

• 

The appliance and flue system must be installed in accordance with ASNZS2918:2001 and the appropriate 

 

Building codes.

 

 

• 

The flue system and fireplace is to be swept annually or more frequently if required.

 

WARNINGS:

 

 

  

WARNING; ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN 

   

 

   

WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

 

 

  

WARNING; DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE 

   

 

   

THE FIRE.

 

 

  

WARNING; DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS 

   

 

   

APPLIANCE WHEN IT IS OPERATING.

 

 

  

WARNING; DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.

 

 

  

WARNING;  WHEN OPERATION THIS APPLIANCE AS AN OPEN FIRE USE A SPARK 

   

 

 

   

SCREEN.

 

 

  

CAUTION

:  THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN 

 

 

 

   

ACCORDANCE WITH THESE INSTRUCTIONS

 

 

  

CAUTION

: THE USE OF SOME TYPES OF PRESERVATIVE

-

TREATED WOOD AS A FUEL CAN 

 

 

   

BE HAZARDOUS.

 

 

Industries 1994 LTD

 

PO Box 58652, Botany  2163, Auckland

 

 

www.warmington.co.nz

 

 

NOTE: For Operation Instructions download from the website 

www.warmington.co.nz

 

Model

 

Estimated KW

 

Average KW

 

SI 780 FST

 

17

 

11

 

SI 780T FST

 

19

 

12

 

SI 900 FST

 

23

 

13

 

SI 1100 FST

 

25

 

14

 

Содержание SI 780 FST

Страница 1: ...d current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician See www home...

Страница 2: ...the land in relation to the home has a bearing on how the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to max...

Страница 3: ...950 1150 Cabinet Front Height J 625 705 775 825 Flue K 300 300 325 350 Inner Baffle L 350 350 375 400 Outer Liner 400 400 425 450 Heat Output kW Peak 24 26 32 35 Range 15 17 17 19 18 21 19 22 Estimate...

Страница 4: ...and plinth details 3 Fit the firebox cabinet into position Remove the cabinet top bolt the firebox to the plinth or through to the floor with the bolting points provided on the left and right hand si...

Страница 5: ...e place Caitec weir vent system as close to fireplace as possible CAITEC TECHONOLGY ROOM AIR REPLACEMENT Caitec draws air from an external air source to ensure that combustion air the open fire uses i...

Страница 6: ...335 Hearth Depth O 1910 1910 2060 2110 Hearth Width P 1200 1200 1350 1550 Hearth Projection Q 600 600 600 600 PLAN VIEW OF CABINET CLEARANCES STRAIGHT WALL HEARTH Adaptor fitment Seal adaptor to fireb...

Страница 7: ...1 4 9 1 6 NOTE The last length of flue pipe needs to extend past the liner so that when the top spide and flashing cone are fitted the flashing cone and the flue pipe are flush or that the flue pipe i...

Страница 8: ...ng Butynol Dek tite an additional flue pipe baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 All extern...

Страница 9: ...9 CHIMNEY CHASE FLASHING AND AIR VENTILATION OPTIONS VENTING THROUGH CHIMNEY CHASE VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS Note...

Страница 10: ...Dimension are in mm Copyright 10 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue exit is to c...

Страница 11: ...n mm Copyright 11 RAISED HEARTH CLEARANCES Note A minimum height must be maintained from the top of the cabinet to the ceiling See page 8 SI 780 1100 RAISED HEARTH CLEARANCES Note For combustible floo...

Страница 12: ...NGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO...

Отзывы: