After connecting the weather compensation kit,
adjustment is made according to average external weather
temperature of your province with P04 parameter. Our
authorised service will make this adjustment during
installation.
(P21) Low temperature region selection.
This parameter should be adjusted as 1 for ground heating
or heating systems operating with low temperature. 0
(zero) value is selected for radiator systems to operate at
high temperatures as standard.
(P24) Child Protection
This feature is disabled as default factory setting (0).
Child Protection (key-lock) is enabled when parameter is
adjusted to 1. Keys are locked after 2 minutes following
use when the feature is enabled. Key-lock is released
when the MODE button is hold until cycle is completed
for getting off the child protection
For other functions / parameters to customize your boiler,
please refer to the installation & service manual.
Deareation Function
The boiler has to be switched to OFF mode first. It is
possible to activate deaeration function pressing RESET
and ”-“ for circle time.
“Air” will be displayed on the screen. Boiler will
start the Deareation function.
During this function pump and 3-way valve are activated/
deactivated in order to have deaeration of the hydraulic
plant.
This function ends pushing again RESET and ”-“ for circle
time or at the end of deaeration time: 12 minutes.
Figure 4
Boiler controlled by weather compensation kit
Figure 5
Heating curves for weather compensation kit
Figure 6
Ending the deairation function
20,0
30,0
40,0
50,0
60,0
70,0
80,0
-25
-20
-15
-10
-5
0
5
10
15
20
K=0,75
K=1,5
K=2,2
K=3
K=4,5
K=6
K=9
Boiler Se
tpoin
t
°C
Outside Temperature
°C
2.4. CUSTOMIZING BOILER
FEATURES
As your boiler has an advanced electronic card, operation
conditions and certain parameters related with your
preferences may be changed by our Authorised Service.
Please consult our authorised service when any changes
requested in below given parameters.
(P07) Power Ramp-Up Time.
When boiler starts, there’s a ramp-up time for reaching
requested power from minimum power and this is set as
10 minutes as default. This value can be set from 0 to 80
corresponding to 0 - 800 seconds.
(P08) Central Heating Power.
The maximum Central Heating power can be adjusted by
this parameter.