2.1.5. Operation in Summer Mode

Boiler only operates for heating the domestic hot water in 
this mode. In order to switch to summer mode;

Domestic Hot Water Adjustment 

at Winter

 Position; You can adjust 

the hot tap water temperature 
value between 35 –60 °C with (6) 
and (7) numbered buttons under 
the RESET button. LCD screen 
backlight is turned ON during 
temperature change, °C and 

 

symbol flashes besides the DHW 
temperature value. LCD screen 
backlight is turned OFF after 
adjustment.

In this mode you can adjust the 
Domestic Hot Water temperature 
between 35 – 60 °C with (7) 

 

and (8) 

 numbered buttons.

2.1.4. Operation in Winter Mode

In winter mode, boiler operates both for heating the 
environment and providing Domestic Hot Water. 
Radiator (CH) temperature adjustment is made with 
(3) and (4) numbered buttons in Figure 1 Domestic Hot 
Water temperature adjustment is made with (6) and (7) 
numbered buttons and this temperature is indicated with 
(9) numbered indicator for Radiator (CH) and with (11) 
numbered indicator for Domestic Hot Water.

In such case, combi boiler initially 
gets into Radiator position, its 
symbol 

 flashes on the left 

bottom corner of screen and 
tap symbol 

 is seen at right 

bottom corner. A digital manometer indicating the system 
pressure is located at lower middle section of the screen 
and also existing radiator system temperature is seen on 
the screen at the same time and screen light is turned off.

When boiler is started, flame modulation symbol is seen 
at the middle section of the screen. At that position, you 
can increase 

 and decrease 

 the temperature 

with CH temperature adjustment buttons (see. Figure 
1) (3) between 35 – 80 °C, screen lights when buttons 
are pressed and °C symbol 

 flashes besides the CH 

temperature value.

If you are starting the combi for 
the first time hold 

MODE

 button, 

and release the button after the 
cycle 

 is completed on the 

screen, initially boiler switches 
to radiator position, its symbol 

 will flash on left top corner 

of the screen existing radiator 
installation temperature and 
screen light will turn off.

In order to summer mode hold 

MODE

 button and release the 

button after completion of cycle 
on the screen. At that position, 
symbol 

 flashes at right 

bottom corner of the screen and 
existing tap water temperature 
will be seen on the screen and 
LCD screen backlight is turned 
OFF.

If you have a floor heating system, as our 
Authorised Service adjust your boiler for 

“Low Temperature Operation”

, maximum 

temperature shall be limited with the 

Radiator (CH) temperature adjustment button (3) (e.g. 
maximum 47 °C).

When the boiler is started for 
the first time, screen displays 
nG letter and then a number 
(for instance 25) indicating kW 
power of the device.

Then, OFF letter is displayed,

and LCD screen backlight is 
turned OFF. Now, boiler is at 
STANDBY position. 

LCD screen backlight is turned ON during temperature 
change, °C symbol flashes besides the DHW temperature 
value. Adjustment value is confirmed after backlight is 
turned OFF following the adjustment.

Содержание MINERWA 25 COMBI-IE

Страница 1: ...MINERWA 25 31 COMBI IE MINERWA 25 SYSTEM IE CONDENSING BOILER USER MANUAL...

Страница 2: ...2 warmhaus com MinerWa 25 31 Combi IE MinerWa 25 System IE...

Страница 3: ...OFF STAND BY AND SUMMER WINTER MODES 10 2 1 3 ON OFF STAND BY POSITIONS 10 2 1 4 OPERATION IN WINTER MODE 11 2 1 5 OPERATION IN SUMMER MODE 11 2 1 6 SHUTTING OFF THE BOILER 12 2 2 USE WITH ROOM THERM...

Страница 4: ...iler should be performed by our authorised Warmhaus service Project design and application for LPG use should be performed by the company supplying the tank in accordance with local and legal rules 1...

Страница 5: ...on installation of gas fired heating devices www warmhaus com Manufacturer WARMHAUS Is tma ve So utma Sistemleri Tic A Bursa I ktepe OSB Mah Park Cad No 10 16140 Nil fer Bursa T rkiye WARMHAUS Warmha...

Страница 6: ...G20 DE II 2ELL3B P Natural Gas 20 mbar G20 DE I 2L Natural Gas 25 mbar G25 NL I 2E Natural Gas 25 mbar G25 BE FR I 2ELL Natural Gas 20 mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural...

Страница 7: ...0 mbar G30 AT CH SK II 2E3B P Buthane Gas 50 mbar G30 DE II 2L3B P Buthane Gas 30 mbar G30 NL II 2ELL3B P Buthane Gas 50 mbar G30 DE I 3P Propane LPG 37 mbar G31 BE CH CZ ES FR GB GR HR IE IT LT NL PL...

Страница 8: ...ff the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make a...

Страница 9: ...es should be replaced by the Authorised Service Do not expose the boiler to direct vapour those may arise from cooking places Safety In your own interest and that of safety it is the law that this boi...

Страница 10: ...3 16 18 9 8 14 10 15 12 11 17 RESET It is used for resetting the failure if temporary re starting the boiler MODE Used for Winter Summer OFF mode adjustment Operating modes and related notifications O...

Страница 11: ...en light is turned off When boiler is started flame modulation symbol is seen at the middle section of the screen At that position you can increase and decrease the temperature with CH temperature adj...

Страница 12: ...om thermostats compatible with Warmhaus boilers Do not remove device components during operation Do not place the boiler in a position allowing direct sunlight exposure or near heat sources Manufactur...

Страница 13: ...sing RESET and for circle time Air will be displayed on the screen Boiler will start the Deareation function During this function pump and 3 way valve are activated deactivated in order to have deaera...

Страница 14: ...omestic hot water temperature sensor faulty Boiler does not work in DHW mode but still operational in Central heating mode E04 error code flashing on the screen Domestic heating water temperature sens...

Страница 15: ...FLUE temperature sensor faulty 1 Reset Restart boiler 2 Call for authorised service E 15 Fan failure feedback supply Boiler does not work E15 error code flashing on the screen Fan harness 1 Reset Res...

Страница 16: ...provider 2 Error will remove if supply voltage 170 VAC 5 3 If this failure is observed during calibration calibration can not be complete unless supply voltage 188 VAC 5 E 40 Wrong network frequency...

Страница 17: ...thorised service at first 2 Check RETURN and FLOW sensor on position E 74 Second CH temperature Probe faulty Boiler does not work E74 error code flashing on the screen FLOW and LIMIT Sensor double NTC...

Страница 18: ...ng on the screen Strong flue blockage Combustion problem Wrong flue Gas inlet pressure Aging or rust on the electrode Recirculation of exhaust gas into fresh air Electrode position Combustion calibrat...

Страница 19: ...air Blockage in flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Call for authorised service E 92 Air compensation active Boiler...

Страница 20: ...ctrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blockag...

Страница 21: ...oximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat loss will occur and not having...

Страница 22: ...22 warmhaus com...

Страница 23: ...nt have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold...

Страница 24: ...and 24 hour emergency line immediately or 1850 20 50 50 Don t assume somebody else has reported the smell Carbon monoxide information For further Information on carbon monoxide call 1850 79 79 79 The...

Отзывы: