background image

17

warmhaus.com

Error

Code

Description of the 

Error

Malfunction

Probable Cause

Solution(s)

E 44

Cumulated 

intermittent

ignition without 

reaching

burner ignition.

Boiler does not 

work, E44 error 

code flashing on 

the screen

> Intermittent 

contacts on harness

> Hammer effect on 

water net

> Too many 

requests in short

time

1) Reset & Restart boiler

2) Call for authorised service

E 62

Calibration request

Boiler does not 

work, E62 error 

code flashing on 

the screen

> Calibration not 

done

> Replacing board 

but not service

key from the old 

board (PCB)

> Service key 

damaged or

disconnected

> Updating 

Software

1) Call For authorised service

E 72

Delta T heating 

at ignition not 

occurred

Boiler does not 

work, E72 error 

code flashing on 

the screen

> FLOW OR 

RETURN Sensor 

not in

position

1) Call for authorised service at first

2) Check RETURN and FLOW sensor on 

position.

E 74

Second CH 

temperature Probe 

faulty

Boiler does not 

work, E74 error 

code flashing on 

the screen

> FLOW and LIMIT 

Sensor (double NTC 

) faulty

1) Reset & Restart boiler

2) Call for authorised service.

E 77

Absolute current 

values reached

Boiler does not 

work, E77 error 

code flashing on 

the screen

> Gas inlet pressure

> Aging or rust on 

the electrode

> Recirculation of 

exhaust gas into 

fresh air

> Blockage in flue 

or wrong flue

> Electrode position

> Cabling 

disconnections

> Combustion 

calibration

> Electronic board

> Gas valve failure

1) Call for authorised service

E 78

Max regulation 

current value 

reached

Boiler does not 

work, E78 error 

code flashing on 

the screen

> Gas inlet pressure

> Aging or rust on 

the electrode

> Recirculation of 

exhaust gas into 

fresh air

> Blockage in flue 

or wrong flue

> Electrode position

> Cabling 

disconnections

> Combustion 

calibration

> Electronic board

> Gas valve failure

1) Call for authorised service

Содержание MINERWA 25 COMBI-IE

Страница 1: ...MINERWA 25 31 COMBI IE MINERWA 25 SYSTEM IE CONDENSING BOILER USER MANUAL...

Страница 2: ...2 warmhaus com MinerWa 25 31 Combi IE MinerWa 25 System IE...

Страница 3: ...OFF STAND BY AND SUMMER WINTER MODES 10 2 1 3 ON OFF STAND BY POSITIONS 10 2 1 4 OPERATION IN WINTER MODE 11 2 1 5 OPERATION IN SUMMER MODE 11 2 1 6 SHUTTING OFF THE BOILER 12 2 2 USE WITH ROOM THERM...

Страница 4: ...iler should be performed by our authorised Warmhaus service Project design and application for LPG use should be performed by the company supplying the tank in accordance with local and legal rules 1...

Страница 5: ...on installation of gas fired heating devices www warmhaus com Manufacturer WARMHAUS Is tma ve So utma Sistemleri Tic A Bursa I ktepe OSB Mah Park Cad No 10 16140 Nil fer Bursa T rkiye WARMHAUS Warmha...

Страница 6: ...G20 DE II 2ELL3B P Natural Gas 20 mbar G20 DE I 2L Natural Gas 25 mbar G25 NL I 2E Natural Gas 25 mbar G25 BE FR I 2ELL Natural Gas 20 mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural...

Страница 7: ...0 mbar G30 AT CH SK II 2E3B P Buthane Gas 50 mbar G30 DE II 2L3B P Buthane Gas 30 mbar G30 NL II 2ELL3B P Buthane Gas 50 mbar G30 DE I 3P Propane LPG 37 mbar G31 BE CH CZ ES FR GB GR HR IE IT LT NL PL...

Страница 8: ...ff the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make a...

Страница 9: ...es should be replaced by the Authorised Service Do not expose the boiler to direct vapour those may arise from cooking places Safety In your own interest and that of safety it is the law that this boi...

Страница 10: ...3 16 18 9 8 14 10 15 12 11 17 RESET It is used for resetting the failure if temporary re starting the boiler MODE Used for Winter Summer OFF mode adjustment Operating modes and related notifications O...

Страница 11: ...en light is turned off When boiler is started flame modulation symbol is seen at the middle section of the screen At that position you can increase and decrease the temperature with CH temperature adj...

Страница 12: ...om thermostats compatible with Warmhaus boilers Do not remove device components during operation Do not place the boiler in a position allowing direct sunlight exposure or near heat sources Manufactur...

Страница 13: ...sing RESET and for circle time Air will be displayed on the screen Boiler will start the Deareation function During this function pump and 3 way valve are activated deactivated in order to have deaera...

Страница 14: ...omestic hot water temperature sensor faulty Boiler does not work in DHW mode but still operational in Central heating mode E04 error code flashing on the screen Domestic heating water temperature sens...

Страница 15: ...FLUE temperature sensor faulty 1 Reset Restart boiler 2 Call for authorised service E 15 Fan failure feedback supply Boiler does not work E15 error code flashing on the screen Fan harness 1 Reset Res...

Страница 16: ...provider 2 Error will remove if supply voltage 170 VAC 5 3 If this failure is observed during calibration calibration can not be complete unless supply voltage 188 VAC 5 E 40 Wrong network frequency...

Страница 17: ...thorised service at first 2 Check RETURN and FLOW sensor on position E 74 Second CH temperature Probe faulty Boiler does not work E74 error code flashing on the screen FLOW and LIMIT Sensor double NTC...

Страница 18: ...ng on the screen Strong flue blockage Combustion problem Wrong flue Gas inlet pressure Aging or rust on the electrode Recirculation of exhaust gas into fresh air Electrode position Combustion calibrat...

Страница 19: ...air Blockage in flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Call for authorised service E 92 Air compensation active Boiler...

Страница 20: ...ctrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blockag...

Страница 21: ...oximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat loss will occur and not having...

Страница 22: ...22 warmhaus com...

Страница 23: ...nt have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold...

Страница 24: ...and 24 hour emergency line immediately or 1850 20 50 50 Don t assume somebody else has reported the smell Carbon monoxide information For further Information on carbon monoxide call 1850 79 79 79 The...

Отзывы: