2.1.4. Operation in Summer Mode

Boiler only operates for heating the domestic hot water in this mode. In 

order to switch to summer mode;

2.1.5. Shutting off the Boiler

To set the boiler to OFF position while it is in SUMMER position;

If you are starting the combi for the first 

time hold 

MODE

 button, and release the 

button after the cycle 

 is completed 

on the screen, initially boiler switches 
to radiator position, its symbol 

 

will flash on left top corner of the screen 

existing radiator installation temperature 

and screen light will turn off.

In order to summer mode hold 

MODE

 

button and release the button after 

completion of cycle on the screen. At 
that position, symbol 

 flashes at right 

bottom corner of the screen and existing 

tap water temperature will be seen on the 

screen and LCD screen backlight is turned 

OFF.

In this mode you can adjust the Domestic 

Hot Water temperature between 35 – 60 
°C with (7) 

 

and (8) 

 numbered 

buttons.

LCD screen backlight is turned ON during temperature change, °C symbol 

flashes besides the DHW temperature value. Adjustment value is confirmed 

after backlight is turned OFF following the adjustment.

To set the boiler to 

OFF

 mode while it is in 

WINTER

;

Press and hold 

MODE

 button and release 

the button after cycle on the screen 

 

is completed, boiler will switch to 

SUMMER

 

mode.

Then, when the same transaction is 
repeated, after cycle is completed 

 

will be displayed on backlight is turned 

OFF boiler is now at 

STANDBY

 position.

Press and hold 

MODE

 button and release 

the button after cycle on the screen 

 

is completed, 

 will be displayed on 

the screen, backlight is turned OFF, now 

the boiler is in OFF mode.

0007_00.W160721

0014_00.W160721

0007_00.W160721

0015_00.W160721

0015_00.W160721

0012_00.W160721

0013_00.W160721 

Содержание Enerwa Plus 2530

Страница 1: ...CONDENSING COMBI BOILERS USER MANUAL ENERWA PLUS...

Страница 2: ...cluding children with limited mental and sensory capabilities or by persons who do not have enough experience and or knowledge unless they are supervised by a person who is responsible for their safet...

Страница 3: ...of On Off Stand by and Summer Winter Modes 8 2 1 3 On Off Stand by Positions 8 2 1 4 Operation in Winter Mode 8 2 1 5 Operation in Summer Mode 9 2 1 6 Shutting off the Boiler 9 2 2 USE WITH ROOM THERM...

Страница 4: ...le The maintenance and repairs as the result of failure of the product within the warranty period due to material production and installation errors shall be performed as free of charge without claimi...

Страница 5: ...mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural Gas 25 mbar G25 NL II 2ELL3B P Natural Gas 20 mbar G25 DE I 3 Buthane Gas 28 30 mbar 37 mbar G30 BE CH CY CZ ES FR GB GR IE IT LT PT S...

Страница 6: ...ly at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make any intervention...

Страница 7: ...s in this booklet are strictly followed for safe and economical operation of the boiler Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate...

Страница 8: ...ment change will be activated when radiator symbol rapidly flashes DHW adjustment change will be activated when tap symbol rapidly flashes CH Central Heating DHW Domestic Hot Water When the boiler is...

Страница 9: ...een on the screen and LCD screen backlight is turned OFF In this mode you can adjust the Domestic Hot Water temperature between 35 60 C with 7 and 8 numbered buttons LCD screen backlight is turned ON...

Страница 10: ...ice installation shall only be performed by the Warmhaus Authorised Service The dual cable required for installation is supplied by the dealer consumer Maintenance and Service Life Warmhaus room therm...

Страница 11: ...tor systems to operate at high temperatures as standard P24 Child Protection This feature is disabled as default factory setting 0 Child Protection key lock is enabled when parameter is adjusted to 1...

Страница 12: ...ler and check if problem is resolved 5 Call for authorised service E 08 Flame circuit failure False flame signal from combustion or electrode Condensate Syphon blocked Electronic board 1 Call for auth...

Страница 13: ...mmunication error Boiler does not work E43 error code flashing on the screen after 1 minute of communication error Opentherm line disconnected 1 Remove energy from boiler and re energize E43 will be r...

Страница 14: ...disconnections Gas valve failure 1 Call for authorised service E 88 Fault of electronic gas valve managing circuit Boiler does not work E88 error code flashing on the screen Cabling disconnections Ga...

Страница 15: ...ectrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blocka...

Страница 16: ...and also you can acquire approximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat l...

Страница 17: ...relevant European directives Differences to product information listed elsewhere may result in different test conditions Only the data that is contained in this product information is applicable and...

Страница 18: ...ion Qfuel kWh 14 809 23 152 23 615 23 078 29 317 Annual fuel consumption AFC GJ 11 18 18 18 23 Condensing boiler Yes Yes Yes Yes Yes Low temperature boiler Yes Yes Yes Yes Yes Combi Boilernation boile...

Страница 19: ...19 warmhaus co uk...

Страница 20: ...dent s Plant Protection team Cadent provide first line support for our assets Gas Emergencies If you smell gas or have accidentally hit the NTS pipeline please call us urgently 0800 111 999 Electricit...

Отзывы: