Thermostats

Warmboard Comfort System offers 3 different types  
of thermostats: 

 

f

Heating

 

Controls the heat in one zone of the house

 

f

Cooling/Heating

 

Controls one cooling zone and one heating zone 
(limit 2 per Warmsource-N/P) 

 

f

Floor Warming/Heating 

 

Controls the heat in one bathroom and offers a 
warming feature which keeps the floor warm even 
when heat is not called for (can be enabled/disabled 
by the homeowner)

THERMOSTAT INSTALLATION 

Every thermostat 

MUST

 be installed in the location 

specified in the WCS Design Drawings. Failure to  
do so will cause the system to behave inaccurately.  
If there are any discrepancies regarding the 
thermostat or zoning, contact us immediately. 

 

f

Remove the appropriate thermostat from the box

 

f

Grip the “face” of the thermostat on the sides with 
one hand, and the back of the thermostat with the 
other hand, then slowly separate the pieces

 

f

Set the “face” of the thermostat to the side

 

f

Connect the hot and neutral (black and white) wires 
from the back piece to the connections in the junction 
box, then fasten into place with the provided screws 
– be sure the arrows point “up” (

see photo

)

 

f

Snap the face plate back into place

 

f

Repeat for each thermostat, always checking to 
make sure they are installed in the correct location

After texture and paint, each thermostat  

MUST

 be installed in the correct location in 

order for the system to perform properly.

Содержание Warmsource-N

Страница 1: ...1 1 800 556 0595 for assistance FOR USE WITH Warmsource N natural gas boiler Warmsource P propane gas boiler Warmboard Comfort System INSTALLATION GUIDE 1021...

Страница 2: ...e exhaust gas vent is required 7 The constant pressure circulation pump s inside Warmsource N P adjust flow rates depending on the needs of each zone 8 Once system plumbing is complete test the system...

Страница 3: ...and WCS f Foundation and joist f Install Warmboard S f Install tubing some loops before walls f Frame walls roof sheeting f Install tubing manifolds some loops f Install all 120 volt electrical boxes...

Страница 4: ...red by code in many jurisdictions it prevents water in the closed loop system from mixing with the domestic water f Air purging valves a 1 1 4 combo ball valve hose bib along with several smaller valv...

Страница 5: ...ibution lines for 15 minutes at 100 PSI International Mechanical Code section 1208 1 MINIMUM CLEARANCES This illustration shows the recommended minimum dimensions for the Warmsource N P mechanical are...

Страница 6: ...301 2 56 11 4 Brass Union supply 11 4 Brass Union return 3 Air Intake T P Relief Valve 3 Exhaust 53 4 57 8 6 3 4 Gas line left side preferred right side OK Condensation Discharge Line 361 2 171 2 21 2...

Страница 7: ...cket the unit weighs 150lbs and requires two individuals to move safely CONNECTIONS f Connect the PVC intake and exhaust lines gas line condensation discharge line and T P relief discharge line per th...

Страница 8: ...ng the system with water for 10 15 minutes until air cannot be seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Ensure the pressure gauge located inside Warms...

Страница 9: ...p 3 Plug Warmsource N P into the 120 volt outlet and confirm the system is ON using the rocker switch and power button circled in the photo to the right Warmsource N P will reach the target temperatur...

Страница 10: ...sign Drawings CONTROLS Warmboard Controls consist of the following f 120 volt thermostats one per heating zone f 120 volt Manifold Controller one per manifold f 24 volt solenoid valve loop actuators o...

Страница 11: ...inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat on the sides w...

Страница 12: ...rminal connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24v power red wire Y Cooling Call yellow wire G Fan green wire f T...

Страница 13: ...inutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineere...

Страница 14: ...E ARE EXPRESSLY EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANUFACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSIBLE...

Отзывы: