WAREMA WMS SA 1 UP Скачать руководство пользователя страница 1

1

warema_2034876_alhb_en_v2•2021-04-01

We reserve the right to make technical modifications

General information

Fig. 1  WMS SA 1 UP

The WMS SA 1 UP is used to simply and conveniently 

retrofit sun shading drives, lighting equipment and window 

drives with a wireless remote control.  

The functionality of the WMS SA 1 UPs is parameterisable 

and can be adapted for different products.

Intended use

The WMS SA 1 UP is an electronic device developed 

to control sun shading systems, lighting equipment 

and window drives. Any use other than the purpose 

described in these instructions requires approval from the 

manufacturer.

Safety instructions

ARNING

W

 

Electrical installation must be performed 

by a certified electrician in accordance 

with VDE 0100 or the legal requirements 

and standards of the country in which the 

device is being installed. The electrician 

must observe the installation instructions 

included with the electrical devices 

supplied.

ARNING

W

 

If it can be assumed that safe operation 

is not possible, the device must not be 

put in operation or has to be taken out of 

operation. This assumption is justified if 

 

  

the housing or the connecting lines show 

signs of damage

 

  

the device is no longer working. 

ARNING

W

 

Switch off the operating voltage of the 

WMS SA 1 UP whenever you perform 

activities on the products connected to 

the WMS SA 1 UP or change connected 

lighting equipment. Danger due to sudden 

movements of the equipment or electric 

shock.

AUTION

C

 

Never press the buttons on your transmitter 

randomly without a line of sight to the sun 

shading system. Children must not play with 

this product – remote controls or transmitters 

must not get into the hands of children!

AUTION

C

 

When using window drives, the installer 

of the system must ensure that the 

safety regulations and precautions 

of DIN EN 60335-2-103 "Particular 

requirements for drives for gates, doors and 

windows" as well as ASR 1.6 "Windows, roof 

lights, transparent walls" are observed.

ARNING

W

 

The WMS SA 1 UP may only be used to 

control window drives where the movement 

of the window cannot cause any injuries.

Due to both the legal regulations for radio systems and 

structural factors, the operating range of radio remote 

controls is limited. Sufficient radio reception must be 

ensured when planning the project. 

Installation

The device is intended for installation in a deep flush-

mounted box (min. 

dia. 60 m

m, depth 65 mm). 

 

 

When using multiple WMS SA 1 UPs, the distance 

between the sensors must be at least 0.3 m!

 

 

Check that the WMS SA 1 UP is functioning properly 

before final installation.

Strong local transmitter systems (e.g. WLAN) with 

transmission frequencies identical to those of the control 

may interfere with reception. 

Operating and installation instructions

WMS SA 1 UP

Valid from  

1 April 2021

Keep for future use.

Содержание WMS SA 1 UP

Страница 1: ...ivities on the products connected to the WMS SA 1 UP or change connected lighting equipment Danger due to sudden movements of the equipment or electric shock AUTION C Never press the buttons on your transmitter randomly without a line of sight to the sun shading system Children must not play with this product remote controls or transmitters must not get into the hands of children AUTION C When usi...

Страница 2: ...l push buttons cannot trigger wireless com mands All additional information on the electrical connec tion can be found in the wiring diagram see Fig 2 on page 6 and Fig 3 on page 6 Commissioning You can find instruction videos on our YouTube channel at http www youtube com user SonnenLichtManager videos We recommend commissioning using the WMS studio pro PC software Switch on the mains supply Lear...

Страница 3: ... blind moves in the selected direction e g up Briefly press the up or down push button The external venetian blind turns in the selected direction e g slats tilt up Push button in opposite direction Product stops Roller shutter Press the up or down push button The roller shutter moves in the selected direction e g up Push button in opposite direction Product stops Awning Press the up or down push ...

Страница 4: ... in opposite direction Product stops Light Push the button switch Switch product ON OFF OFF ON Comfort position If a product is already in the comfort position or if a comfort position has not been stored the selected product does not respond when the up and down push buttons are pressed at the same time Comfort position Learn Press the up or down push button Move to desired position in this case ...

Страница 5: ...ues are being received by the corresponding sensor at regular intervals If the WMS SA 1 UP has not received a measured value in 24 h it is assumed the sensor or the weather station has failed Heartbeat function The WMS SA 1 UP moves the connected product to a safe position Depending on the type of sun shading product operation is limited or impossible until a new valid value is received This is a ...

Страница 6: ... be connected per WMS SA 1 UP PE N L Supply line 230 V AC 50 60 Hz 6 A F terminal P Push button Push button terminal 1 1 2 2 3 3 Plug and socket connection H05RR F 4 G 0 75 BK NYM J 5x1 5 max 25 m motor 1 2 3 M Fig 2 Motor connection example WMS SA 1 UP local button output N L PE N L power line on site 230 V AC 50 60 Hz 6 A F NYM J 5x1 5 switch max 25 m NYM J 3x1 5 terminal terminal WMS SA 1 UP lo...

Отзывы: