7.1.6 Uemperature control
OA/OFF
To activate or deactivate the temperature control, set or delete the checkmark
in the [
Temperature control ON/OFF
] line.
The [
Stand.
] function button switches the temperature control on or off, de-
pending on the channel type.
7.1.7 Uemperature
The "Temperature" value specifies at which temperature a sun shading prod-
uct is lowered by the temperature control. The setting range is –10...+50 °C.
To set the value for the temperature, turn the touch wheel to the desired posi-
tion.
The [
Stand.
] function button sets the value to the factory setting.
At the same time, the limit value for raising the sun shading is set 5 °C lower
to ensure flawless functioning of the automatic feature.
7.1.8 Precipitation monitor
OA/OFF
To activate or deactivate the precipitation monitor for the selected channel,
set or delete the checkmark in the [
Precipitation monitor ON/OFF
] line.
The [
Stand.
] function button sets the precipitation monitor to the standard
setting typical for the channel type.
CDAUIOA
The precipitation monitor is an adjustable safety function and was therefore
assigned to the comfort functions. If you have deactivated the function and
retract an awning wet from the rain, you must take care yourself to extend it
again in a timely manner to let it dry off during dry weather to prevent mould
from forming! An extended awning can also be damaged during rain by the
formation of water pockets!
7.1.9 Intermittent ventilation
Intermittent ventilation opens and closes motor-operated windows at adjust-
able intervals. This ensures sufficient fresh air supply in your rooms and pre-
vents mould formation through excessive air humidity.
Set or delete the checkmark in the line [
Intermittent ventilation
] to acti-
vate or deactivate the intermittent ventilation mode.