![WAREMA Wisotronic 2 Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/warema/wisotronic-2/wisotronic-2_installation-instructions-manual_872115086.webp)
890564_c•en•01.08.2013
We reserve the right to carry out improvements
86
Wisotronic 2/3/4-channel
Installation instructions
Channels
9.3.3 Sensor allocation
CAUTION
Changing these settings may impair the safety of the system or reduce its
effectiveness. Therefore, be sure that you are aware of the effects when you
make a change.
The sensors must be allocated to the channels for the control to function
properly. In doing so, you define how the sensors are used for controlling the
individual channels.
These variables are later evaluated by the safety and comfort functions when
triggering move commands and actions. Up to twelve measured values from
up to three weather stations can be assigned per channel. Of these, up to
four can be "Photo" values and the value that is currently the highest is deci-
sive. The photosensors are allocated to the installation location as follows:
A
B
C
2
3
4
Fig. 36
Alignment of the photo diodes (example: multisense weather station)
NOTE
The numbers 1 to 4 have been factory-assigned to the four photodiodes. (Po-
sition photodiode 1 to face northward as far as possible.) Position the photo-
diodes according to the building facades being shaded. It will be far easier
to allocate the photodiodes to the individual functions of the Wisotronic later
on if you connect the photodiodes to the Wisotronic according to their num-
bers. Additional information can be found in the sensor operating and instal-
lation instructions.
Pho
to
1
(Dawn/Dusk)
Pho
to
3
Photo 4
Photo 2
N