Product description

Black-out blind type VDA 13

General functions and application areas (intended use)

The black-out blind type VDA 13 is designed as a vertical 
black-out element for interiors. It consists of continuous light-
proof material that can be rolled up and that completely 
darkens the interior. Guide rails prevent light from entering the 
room on the sides of the blind. 
The black-out blind type VDA 13 can be supplied as a left or 
right roller, crank operated or motor operated, and individually 
or as a group system. The blind is installed in or on the soffit 
or in the drop ceiling.

Crank operation: 

The blind is operated using an aluminium 

crank.

Motor operation:

 The maintenance-free motor lowers and 

raises the blind after a pushbutton switch or snap-in switch is 
activated (or using a control unit). The equipment is electrically 
connected to the connector provided on-site by a qualified 
electrician.
The curtain is completely impermeable to light, resistant to 
infrared radiation, hardly inflammable (textile fabric) or not 
inflammable, and can be delivered in 5 colours (depending on 

the version). The box and guide rails are available in all RAL 
colours. 
The black-out blind type VDA 13 is especially suitable for 
rooms that must be completely darkened – e.g. lecture halls 
and auditoriums, meeting rooms, photo labs, x-ray rooms and 
operating theatres.
The room is darkened by lowering the blind to the required 
position. Total darkness can only be achieved by completely 
lowering the blind (sealing strip on drop rod completely closes 
with window sill and is light-proof). 

The use of black-out blind type VDA 13 in escape routes 
(emergency exit doors or windows) or in front of windows 
with an SWE control unit is only permissible with special 
accessories.

Only use black-out blind type VDA 13 for visual privacy and 
light protection and for darkening interiors – never as an all-
weather protection or as lifting or pulling equipment.

1 Box cover

2 Inspection cover

3 Side cover

4 Guide rail

5 Sealing strip

6 Drop rod

7 Fabric

8 Crank rod (only with crank operation)

9 Crank holder (only with crank operation)

10 Crank handle (only with crank operation)

V

D

A

1

3

_

1

Fig. 1:

Black-out blind type VDA 13

1

3

4

6

9

10

5

7

2

8

Содержание VDA 13

Страница 1: ...WAREMA black out blinds Type VDA 13 Operating instructions For handing out to users Valid from 23 February 2005 Document no B866108_0 fm EN ...

Страница 2: ... carefully before operating your blinds adhere to the operating steps and keep in mind the helpful hints and recommendations In addition to the information regarding operation of the blinds these instructions also contain important maintenance and care tips The black out blinds were developed manufactured tested and documented according to relevant safety standards When used properly they do not r...

Страница 3: ...cal data 6 Motor data and further technical data 6 Safety information Symbol legend 7 Important safety information 7 Operation Safety information 8 Crank operation 8 Operation with switch 9 Operation with motor and external control device 9 Irregular situations Malfunction 10 Maintenance service 11 Accessories 11 Spare parts 12 Cleaning 11 Warranty 12 Repair 12 Dismantling disposal 12 Liability 12...

Страница 4: ...ype VDA 13 Identification The factory order number and item number are printed on the drop rod and box position of components see Fig 1 on page 5 of every WAREMA black out blind type VDA 13 This allows the manufacturer to clearly identify each individual product ...

Страница 5: ...n hardly inflammable textile fabric or not inflammable and can be delivered in 5 colours depending on the version The box and guide rails are available in all RAL colours The black out blind type VDA 13 is especially suitable for rooms that must be completely darkened e g lecture halls and auditoriums meeting rooms photo labs x ray rooms and operating theatres The room is darkened by lowering the ...

Страница 6: ...otor protection class IP44 Size weight max dimensions WxH 2 m x 6 m individual units or 4 5 m x 2 7 m individual unit max two slave elements Fabric weight depending on type 0 54 kg m2 to 0 57 kg m2 Crank rod Crank handle aluminium Long crank rod according to customer requirement max torque 3 7 Nm Size weight max dimensions WxH 1 m x 6 m individual units or 4 5 m x 1 3 m individual unit max two sla...

Страница 7: ...this is the case please contact your WAREMA dealer Never let children play with the control elements If your unit is equipped with a remote control unit keep it out of reach of children Unintentional activation of the control unit may lead to injury product damage Electrical electronic devices are not failsafe e g in case of power failure Ensure that this does not pose a potential hazard for perso...

Страница 8: ...icer responsible for this area Warning Risk of pinching Ensure that no persons or objects are located in the extension area of the black out blind Keep persons at a distance until the product has reached its final position Caution Danger from broken glass In direct sunlight the blind should always be extended to the end position to avoid large temperature gradients in the glass panes This lowers t...

Страница 9: ... of the blind is electronically limited The blind will stop automatically at these positions Operation with motor and external control device If your black out blind is equipped with a motor and a control unit please read the separate instructions for the control unit Follow the relevant instructions under Safety information on page 7 w01752v3 Fig 3 Switch operation in units with motor drive Warni...

Страница 10: ...lind does not move with master blind Hexagonal coupling bolt is missing or not locked Insert the hexagonal coupling bolt or fixing screw and tighten qualified technicians only Crank cannot be operated Gear is malfunctioning Gear change qualified technicians only Crank or pivot bearing is malfunctioning Replace the crank or angular piece qualified technicians only Blind extends at a slant Diverse R...

Страница 11: ...tion A high pressure washer should not be used to clean the product as the pressure and heat may damage the unit and the surrounding wall n Extend the unit completely n Deactivate the higher level control if present n Use suitable climbing aids and do not hold on to the unit n Remove dust with a soft brush n Only clean the product with commercially available mild household cleaners for delicate su...

Страница 12: ...ded Follow the instructions in the operating manual of your sun shading system Liability cannot be accepted for damage to the sun shading system due to operation in icy conditions Caution Risk of personal injury or property damage from the use of incorrect spare parts Only use spare parts approved by WAREMA Please contact your WAREMA dealer or the manufacturer The manufacturer guarantees the deliv...

Страница 13: ...02 Qualified technicians Qualified technicians are persons familiar with the transport erection installation startup and operation of the product and who have the necessary qualifications for their tasks The technicians must know and comply with the applicable standards and regulations Right rolling blind The right rolling blind unwinds the curtain towards the window SHE SHE Smoke heat extraction ...

Страница 14: ...14 B866108_0 fm EN 23 02 2005 Notes ...

Страница 15: ... B866108_0 fm EN 23 02 2005 15 ...

Страница 16: ...re trademarks or registered trademarks of the respective holder Considerable care was taken in producing the text and graphics in this documentation but it is impossible to rule out errors completely No liability is accepted for any errors which may exist in this documentation nor for possible effects of those errors Company stamp 2005 WAREMA Renkhoff GmbH Hans Wilhelm Renkhoff Straße 2 97828 Mark...

Отзывы: