Service
Page 20 | 24
2029839 [Rev. 3 - en]/2019-03-22
Disconnecting the line
1
3
4
5
2
1
Screws
4
Lines
2
Distribution board
5
Sealing ring
3
Cable clamp screws
Fig. 3:
Disconnecting the line
Unscrew the screws [1] on both sides on the distributor
[2] using a suitable tool.
Release the screws [3] of the cable clamp and remove
the lines [4].
Pull the lines [4] through the sealing ring [5] into the
inside of the housing.
Replacing the heating element
NOTICE
Product damage from incorrect procedure!
Finger prints on the heating element may shorten
the product service life.
Do not touch the heating element of the radiant
heater with bare hands.
Only touch and insert the heating element using
gloves.
After inserting the heating element, wipe it off
with a soft cloth.
1
2
3
1
Screws
3
Line
2
Heating element
Fig. 4:
Replacing the heating element
Push the clamps [1] on the left and right outward
simultaneously until the heating element is free.
Pull the heating element [2] forward and pull the lines [3]
out of the housing.
Insert the new heating element in reverse order.
Connect the lines.
DANGER
Short circuit!
If the sealing ring is not installed properly, water can
enter into the distributor and cause a short circuit.
Only mount the distributor with a sealing ring.
Carefully position the sealing ring.
Check that the sealing ring has been installed
correctly.
Install the safety grille.
Install the radiant heater.
4.5
Warranty
Subject to the statutory period of limitation for warranty
claims. This requires regular maintenance. The warranty
does not include wear parts or optical changes in line
with the type of material used (e. g. bleaching of surfaces
caused by UV rays).
Wear parts for radiant heater (if present)
Heating element