background image

Product information

Additional loads on the product in the form of hanging
objects or guy ropes could damage the product or cause
it to become detached from the wall and are therefore
not permitted. WAREMA will not be liable for any ensuing
damage.

The intended use also includes observing these instructions
and adhering to the service requirements they describe.

Optional:

Integrated awning with easyZIP guidance

The product is an external textile sun shading system that
may be used for thermal protection, glare control and visual
privacy on vertical glass surfaces. The product reduces the
incidence of light and optimises the use of solar energy.

The product is intended to be used to protect against the
sun, not the rain.

Optional:

LED strips

The product consists of an electronic LED lighting device
(warm white light) for outdoor installation. In the slat roof,
the power supply of the LED strips is provided via the WMS
Dimmer smart.

Optional:

RGB strips

The product consists of an electronic lighting device make
of RGB LEDs for outdoor installation. In the slat roof, the
power supply of the RGB-LED strips is provided via the
RGB Dimmer ZigBee.

Optional:

Radiant heater

The product is designed to generate radiant heat outdoors.

The product is connected to a mains voltage of 230 V/50 Hz
via the WMS Plug receiver power.

Optional:

WMS Weather station plus

The product enables the wireless control of sun shading
product and is equipped with a sensor for brightness,
precipitation, temperature and wind speed. The
weather station may be connected to a mains voltage of
230 V/50 Hz and must be set to the value specified for the
product.

2.2

Parts description

1

2

3

5

4

1

Pole

4

Integrated awning
with the easyZIP
guidance (optional)

2

Beams

5

Integrated LED strips
(optional)

3

Slats

Fig. 1:

 Parts description using Lamaxa L70 as an example

(without wall connection)

2.3

Electrical data

Data for electric drive of slat roof

Parameter

Value

Current consumption [A]

0.9 A

Rated voltage

230 V/50 Hz

Degree of protection

IP 44

Short-term operation (S2)

4 min

Emissions sound pressure level

LpA 

 70 dB(A)

*

*

The sound pressure level LpA in a standard
installation of the product on a test stand is

 70 dB(A). This value may vary depending on the

specific installation.

Page 6 | 32

2029839 [Rev. 9 - en]/2021-10-11

Содержание Lamaxa L60

Страница 1: ...User instructions WAREMA slat roof Lamaxa L60 L70 Original instructions To be handed over to the opera tor Please keep for future use Valid from 11 October 2021 Document number 2029839 Rev 9 en...

Страница 2: ...3 3 Operating the slat roof with the WMS Hand held transmitter 13 3 4 Operating the integrated awning with easyZIP guidance with WMS Hand held transmitter if present 16 3 5 Operation using WMS Weather...

Страница 3: ...t on the product other than as described in these instructions without the written approval of WAREMA 1 3 Explanation of the signal words DANGER Identifies an imminent danger that may result in death...

Страница 4: ...must be kept out of the reach of children Access to the radiant heater if present The radiant heater is not intended for children Children are unable to recognize the danger posed by the product Perso...

Страница 5: ...Intended use The following details apply to the following product slat roof Lamaxa L60 L70 The product is a weather proof large area external sun shading system that may be used for protection against...

Страница 6: ...installation In the slat roof the power supply of the RGB LED strips is provided via the RGB Dimmer ZigBee Optional Radiant heater The product is designed to generate radiant heat outdoors The product...

Страница 7: ...ta for RGB strips if present Parameter Value Output voltage 24 V Degree of protection IP 54 max power 12 W m Data for ZigBee RGB Dimmer smart if present Parameter ZigBee RGB Dim mer smart 150 W Operat...

Страница 8: ...21 17 13 13 13 Up to 5000 21 17 13 13 13 Up to 5500 17 17 13 13 13 Up to 6000 17 17 13 13 10 Tab 5 Wind speed limits for integrated awnings with easyZIP guidance details in m s The table values Beauf...

Страница 9: ...O When fully equipped not all components can be operated with a hand held transmitter The hand held transmitter has 6 channels A Channel no Assignment standard 1 Assignment customer specific 1 Drive 2...

Страница 10: ...button for light setting made at the factory 1 The channels are assigned at the factory if all specified components are present upon delivery The preassigned channel changes if an additional accessor...

Страница 11: ...1 channel LED lighting in pole 1 4 fields optional 1 1 channel Radiant heater field 1 optional 1 1 channel Radiant heater field 3 optional 1 1 channel Integrated awning with easyZIP guidance optional...

Страница 12: ...D pole A1 3 Radiant heater field 1 A1 4 Radiant heater field 3 A1 5 LED beam direct A2 and B1 6 LED beam indirect A2 and B1 7 LED pole A2 and B1 8 Radiant heater field 1 A2 and B1 9 Radiant heater fie...

Страница 13: ...operation Persons who are located within the projection area may be injured Keep the path of the product clear of people Keep children away from the operating elements Ventilation The air is circulat...

Страница 14: ...close the slats Press the DOWN button briefly Turn the slats step wise into the selected direc tion When the lower limit position is reached slats closed the motor stops automatically Operating Lamaxa...

Страница 15: ...ition 90 INFO Select the right channel for the product on the hand held transmitter The exact description of the hand held transmitter can be found in the accompanying instructions for the hand held t...

Страница 16: ...t The product can be stopped in any position Lowering Press the DOWN button briefly The awning lowers Stopping if necessary Press the STOP button briefly The movement is stopped Operating the integrat...

Страница 17: ...r Winter November April 3 ZIP Lamaxa Limit value Control mode Position ZIP Limit value Control mode Position L60 Position L70 13 m s 13 m s Wind 48 km h On Retract 48 km h Off Tilt the slats horizonta...

Страница 18: ...r becomes brighter Dimming 1 Press the DOWN button briefly The light goes on or becomes dimmer Operating the light Switching off Press the STOP button briefly The light goes off 1 The LED strip RGB st...

Страница 19: ...ater to cool down before touching it INFO Select the right channel for the product on the hand held transmitter The exact description of the hand held transmitter can be found in the accompanying inst...

Страница 20: ...ved with the product to elimi nate the risk Operation during a storm Slat roof The product must be closed by hand before a bad weather front passes over even if a control unit is be ing used In case o...

Страница 21: ...eactivated in winter Do not operate the product if it is frozen Open the slats of the product if it starts snow ing Switch off the automatic control in winter Cleaning the drainage INFO If the drainag...

Страница 22: ...and may impair the proper functioning of the sun shading product To enhance the durability of the sun shading product its surfaces should be cleaned regularly or at least once a year For awning fabri...

Страница 23: ...REMA dealer For further advice and technical questions regarding cleaning please contact the Association of German Sun Shading Product Cleaners Verband Deutscher Sonnenschutzreiniger e V www vds sonne...

Страница 24: ...the beams to eliminate the possibility of malfunctions e g due to leaves Clean the drainage gutters and drainage pipes to remove any blockages e g due to leaves Remove the detached soiling before dryi...

Страница 25: ...tion cannot restore the awning fabric to its original new condition Cleaning the drain INFO If the drainage gutter is installed without an inclination it must be inspected and cleaned more frequently...

Страница 26: ...drop tubes and outlets for clogging and clean INFO To ensure proper functioning and your continued enjoyment of the product WAREMA recommends professional maintenance Information on this can be obtai...

Страница 27: ...lle 2 3 1 1 Safety grille 3 Housing cover 2 Screws Fig 2 Removing the safety grille De energise the radiant heater Let the radiant heater cool down Disconnect the radiant heater by releasing the conne...

Страница 28: ...on light coloured fabric Chalk lines These are light stripes of the impregnating material on the fabric surface They result from handling the fabric during production and assembly of the units Althoug...

Страница 29: ...n electric shock De energise the product and secure it against being switched on again Disposal Should the product no longer be required ensure that it is disposed of correctly in accordance with the...

Страница 30: ...ified electrician Motor is faulty Replace the motor Replacement by a qualified specialist Fault The product does not move to the desired limit position Cause Remedy Note The motor limit positions are...

Страница 31: ...and awnings Performance requirements including safety DIN EN 60335 2 97 Household and similar electrical appliances Safety Part 2 97 Particular requirements for drives for rolling shutters awnings bl...

Страница 32: ...Machinery Directive 2006 42 EC in the case of motor drives In particular the following harmonised standards were used DIN EN 13561 External blinds and awnings Performance requirements including safet...