Tripod BO-DS112
www.wano.pl
[F 0 6] Zero signal setting:
0: close the gate/ channel immediately if the zero signal is detected (tripod turnstile standard mode, the main board is set to 0 by
default)
1: zero signals are detected, and then the gate is closed after waiting for the zero signals to disappear (commonly used at full
height turnstile).
[F 0 7] Normally open setting of turnstile:
This parameter is used to detect the continuous opening signal. When the continuous opening signal exceeds the set parameter,
the system enters the normally open state.
If it is a continuous signal, the gate will always be open. After the continuous signal is disconnected, the gate will resume the
standard mode.
(The default parameter is 6 seconds, that is, press the "left open" or "tight open for more than 6 seconds, the gate is normally
open, release the "open" button, and the gate is restored.)
[F 0 8] Opening time delay:
This parameter can only be effective when the memory function is turned on. After the memory function is turned on, the time
delay of opening the gate for more than one person can be prevented from opening the gate again when the previous person
has not passed the channel.
[F 0 9] Back to factory settings:
All main board parameters are restored to factory settings.