8.0 REPLACEMENT OF PARTS
2
SEP.SEPCOM_Vertical.--.M.A4.0722.EN Issue: A4
07.22
38
Follow the indications bellow:
1)
Open the junction box and disconnect the electricity con-
nection cables from the motor terminals.
2)
Harness the motor safely so as to avoid dangerous oscil-
lations.
3)
Slacken the bolts (
L
) that fasten the motor (
C
) to the
gear reducer (
D
).
4)
Dismantle the motor from the gear reducer using a mod-
erate decoupling force (do not use a screwdriver or le-
vers as they can damage the flanges).
8.2 Replacing the electric motor
Replace the electric motor with a new one having the same structural and functional features.
If the motor is supplied by the Manufacturer, ask for original spare parts to ensure the safety and functionality
of the equipment.
Disassembly
Danger - Warning
Set the separator in safety condition (see "Glossary and Terminology"). Harness the electric motor
appropriately and use suitable lifting means.
8.1 Safety recommendations for replacement
Danger - Warning
The replacement operations must be carried out by a specialist authorized technician with specific
skills in the sector concerned (mechanical, electrical etc.).
Prior to performing any operation:
1) Provide appropriate safety measures and use suitable equipment to prevent risk of work accident to
persons involved in the operations and to those nearby.
2) Enable all safety devices envisaged and prevent access to controls which, if activated, could cause
work injuries to the persons involved in the operations.
3) Ensure there is enough space for manoeuvring (at least 1 meter around the machine).
4) Make sure that the passage of workers is not hindered.
5) Set up a hoist or lifting system above the machine for safe removal / installation of the components.