Digital Multi-Purpose Controller 97TS500R
Page 17 of 20
Walther Systemtechnik GmbH
– D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de
6.6 Change Display for Pressure Units (see Fig. 9.0)
The preset pressure unit is
“psi”. Follow the below steps to change the display for pressure units to show
"bar":
1. Hold the
“Set” button (3) for two seconds to change into the Setup-display.
2. Simultaneously press the (+) and (-) buttons two times. The
“psi” unit starts blinking.
3. Simultaneously press the mode button (2) and the "Set" button (3) to change the unit to
“bar”. Repeat
this step to change units back to "psi".
4. Hold the
“Set” button (3) for two seconds to exit the Setup-display.
6.7 Low Pressure Setting (see Fig. 9.0)
The low pressure value has been pre-set at the factory to 70 psi (4.8 bar). When the pressure falls below 70
psi (4.8 bar) the device will not operate anymore. Follow the below steps to change the settings for the low
pressure:
1.
Set the dispensing cycle to “TIMED MODE”.
2. Hold the
“Set” button (3) for two seconds to change into the Setup-display.
3. Press (+) and (-) button at the same time. The setting for low pressure appears in the display as shown
in Fig. 6.0.
4. Press "Set" button (3) and (+) button at the same time to increase the value.
5. Press "Set" button (3) and (-) button at the same time to decrease the value.
6. Hold the
“Set” button (3) for two seconds to save the data.
Fig. 10.0
6.8 Setting of Multiple Shots:
Up to ten individual or sequential shots can be stored in the 97TS500R. The sequential mode is activated in
numerical sequence.
1. Follow the steps in paragraphs 6.1.2 (Program Selection) and 6.1.4 (Setting of Automatic Dosing Cycle)
in order to set the dispensing in the desired programs.
2. Hold the mode button (2) for two seconds to activate the sequential mode.
3. Shortly press the Setup button (3) to enter the Setup-mode of the sequential program.
4. Press the button (+) or (-) to indicate the number of programs for dosing times which will be dispensed.
5. Shortly press the Setup button (3) in order to save the selected sequential program.
6. Push the foot switch to activate the sequential dosing cycle.
7. Hold the mode button (2) for two seconds to exit the sequential mode.