Scale Manager 2 

kit comprises of the following: 

 

 

One computerised electronic water descaler   

 

One 12 volt power supply, cable length 1.8m 

– 6'  

      Optional when ordering, 5m - 16½'

 

power supply extension lead  

 

Antenna cable with 

red

 plug 

 

Antenna cable with black plug 

 

Five plastic cable ties (1 spare) 

 

One attachable Black antenna plug 

 

One attachable Red antenna plug 

                   

 

 

Please Note: -

 

Ensure antennae cables do not come into contact with each other  

 

The gap between the coils must be in excess of 60mm - 2½" no upper limit 

 

Coils require a minimum of 50mm - 2" each side of uninterrupted straight pipe 

 

Direction of coils are essential - see over 

 

Ideally a 125mm

 

+ (5"+) straight run of pipe is required for each antenna coil 

 

Direction of Water Flow is immaterial  
Connect red plugs to red sockets and black to black  
Scale Manager is effective on all pipes (copper, plastic, lead, steel etc) 

 

 

Performance is not impaired if the pipe is painted 

 

 

The Control Unit can be fitted at any angle or plane 

 

 

A 13-amp socket is required for the power supply 

 

 

 

The  ideal  location  to  install  Scale  Manager  is  near  the  entry  point  of  the  rising  main,  before  any 
junctions.    The  antennae  coils  operate independently  and can  be  positioned on separate pipes should 
you not have an uninterrupted pipe run of 250mm - 10".  Should the inlet pipe T off within 125mm 

– 10" 

of  the  stopcock,  position  the  coils  as  fig  1  overleaf.    If  the  inlet  pipe  available  is  over  125mm  -  5"  but 
under 250mm - 10" position as fig 2 overleaf.  
 

The antennae coils require a minimum gap between them of 50mm - 2".  It is also necessary that 

the coils are at least 40mm -1½" from elbows and junctions. 

 
Fitting: - The diagram overleaf may be of assistance.  

 

Position the Scale Manager control unit close to the water inlet pipe, allowing sufficient space 
to connect the antennae and power plugs 

 

Connect the RED plugged antenna to a RED socket marked

 Red OUT

  

 

Pass the antenna cable over the front of the pipe and secure with a cable tie  

 

Closely coil the wire around the pipe 12 times - see ov

er in the direction of the arrows

.   

 
5  

Tighten the coil and secure with a cable tie.   

 

Leave sufficient wire to reach the remaining 

Red IN

 socket - 

trim off the excess

. Connect the 

loose  RED  antenna  plug  to  the  cable by  pulling  off  the  plastic  insulation cover  (pliers may  be 
needed) if not already removed - thread wire through the insulation cover - trim off 5mm -¼" of 
insulation  from  the  wire  -  connect  to  the  plug  via  the  screw  terminal  -  replace  the  insulation 
cover - connect to the 

Red IN

 socket on the control unit. 

 

 
Repeat the same process with the BLACK plugged antenna starting by connecting to the 

Black 

IN 

socket, making sure to coil in the direction of arrows

– see over.  

 
 

Plug  the  power  supply  into  a  13-amp  socket,  connect  to  the  socket  on  the  control  unit  and 
switch on. 

 
The power LED will illuminate pulsing for a few seconds whilst carrying out a self-diagnostic routine. The 
R.F. & D.I.C descaling bar graph LED's will then illuminate showing de-scaling is in progress. They will 
cycle at a rate of 1.26 seconds.  Each LED represents 650 magnetic pulses, totalling 6,500  per second 
through each of the antenna coils. 