background image

NB : For a maximum technical safety cover, the gap between the inner pool and  the 

cover edge must be maximum 70 mm. 

 Please contact a qualified technician in order to get such a result.

in order to to get the correct cover adjustement to the pool, it is essential to supply 

to the manufacturer  a pool plan with the width and length measured every meter 

Warranty

The warranty is granted when normal installation, use and wintering are in line with our conditions. WALTER Pscine warrants all defective 

parts replacement during the warranty period as of the service enter date.
Automatic cover installation and repair must be performed  by a qualified technician.

Warranty period

>

4 years for the electrical equipment SIREM (motor, electrobox)

>

3 years for the PVC slats regarding the buyoancy, tightness, disintegration, and articulation. Mechanism is also warranty, except for the corrosion.

>

6 Months for the solar batteries 12V (solar rolling cover)

This warranty does not cover

>

Polycarbonate slats deformation due to lack of contact with the water surface.

>

Acts of God such as hail, storm, lightning.

>

if the product has been modified other than as authorised by Walter without our prior consent.

>

Workmanship costs for the assembly and disassembly.

>

Costs for damages as well as financial penalties.

Information before purchase

Safety cover for pool aimed at preventing the access to children under 5 years old.

Cover model : 

AXIO

Dimensions cover : 

width minimum 2.20 m

Water level :

 minimum 100 mm / maximum 120 mm

Wintering water level :

 minimum 100 mm

Usage period : 

all seasons, except for cover stuck in ice

Beware of hail (please check with your insurance)

Estimated handling time :

 Opening : 3 minutes / closure : 3 minutes

Number of people for handling  :

 1 person

Box unloading : 

4 people

Broduction sheet included :

 by the wholesaler, installer, or customer

20

Содержание AXIO

Страница 1: ...pletely and retain for future reference AUTOMATIC SLATTED POOL COVERS MANUFACTURER Safety cover compliant with French NFP 90 308 norm to be installed and used according this mounting user manual SUBME...

Страница 2: ...standard NFP 90 308 Please maintain the key while opening and closing the cover and more Importantly remove this key after the cover is closed The quality control of the original parcel must be done...

Страница 3: ...width of the pool G 50 cm slat strips 6 slats strip qty depending of the length of the pool H Sandow qty depending of the length of the pool 1 Beam J Duckboardinq qty dependinq of the lenqth of the p...

Страница 4: ...Submerged system AXIO...

Страница 5: ...SHAFT WITH MASONRY SEPARATION WALL...

Страница 6: ...Wall fastening...

Страница 7: ...Angle mounting...

Страница 8: ...PIT WITH PREFABRICATED SEPARATION WALL IN PVC...

Страница 9: ...Wall fastening...

Страница 10: ...Angle mounting...

Страница 11: ...SETTING UP OF THE AXIS...

Страница 12: ...INSTALLATION OF THE BEAM AND GRATINGS...

Страница 13: ...rs MS 2 X 10 23 Stainless steel nut MS 4 X 24 Stainless steel stop rinq diameter 30 l X 25 Shaftbearing diameter 30 X 26 Stainless steel pin diameter 8 X 27 Cover of 83 mm PVC slats 28 l ens X Adjusta...

Страница 14: ...INSTALLATION OF THE SLATS...

Страница 15: ...ABLE COLORS White Sand Blue Light Grey Dark Grey O F Adjustable patented caps Fixed fins Strengthened slat Independant alveolus Cover assembly must be done when the pool is filled with water Make up a...

Страница 16: ...ANTI LIFTING DEVICE POSITIONING OF THE ANTI LIFTING LOOPS...

Страница 17: ...ELECTRICAL CONNECTION...

Страница 18: ...CONTROL UNIT WITH PLC For SIREM motorisations for automatic underwater swimming pool coverings...

Страница 19: ...O 15A Varistor Power supply terminal block Motor power cable terminal block Electrolyser terminal block control rev counter sensor BOX DIMENSIONS 235 1 Terminal block details 131 170 Motor direction r...

Страница 20: ...ain After the system has been activated the engine can be operated lnitialisation 1 Code activation 3 presses on the key then press OK 2 Indicate the position of the motor 3 4th stage uuu 000 00A 1Jt1...

Страница 21: ...closing It also shows the current consumption and the speed of rotation The counter value in closed position around 0 is lower than the counter value in open position between 7000 and 8000 2 A time de...

Страница 22: ...R CONTROL SYSTEM The signal from the rev counter sensor does not change its status The motor is powered continuously for 5 minutes The manoeuvre is suspended and the motor is stopped for 20 seconds No...

Страница 23: ...liance with Norm NF C15 100 Cover components toolbox hammer drill grinder an electric screwdriver an electrical measurement device We advise you to wear handgloves for the manipulation of sharp compon...

Страница 24: ...And always monitor the pool access Depending on the geographical location and the weather conditions your cover will survive the winter if you follow these procedures Clean your cover with a high pre...

Страница 25: ...articulation Mechanism is also warranty except for the corrosion 6 Months for the solar batteries 12V solar rolling cover This warranty does not cover Polycarbonate slats deformation due to lack of co...

Страница 26: ...to supervise children and not to the entire group present around the pool everyone of them may think that another one is watching Do not leave children without supervision a child can drown in a few...

Страница 27: ...danger for your children Drowning happens in a few minutes Please maintain constant vigilance and an active monitoring when children are nearby the pool even if they can swim An adult must always be...

Отзывы: