Troubleshooting
The table below provides information about the most common problems and suggests
steps to resolve them. If this simple guide does not help or in case of doubt, contact a
qualified service engineer.
Problem
Probable cause
Action
Liftgate not working, hydraulic
pump does not start.
Cab switch and/or
main switch in Off
position.
Set the cab switch and/or main switch
in the On position. For information about
the cabin switch and main switch, see
section “3.7 Cab switch” on page 22.
Motor overheated.
Wait for the motor to cool and try again
(may take up to 30 minutes depending on
external conditions). See section “3.11
Overheating protection” on page 27.
Blown fuse / tripped
circuit breaker.
Check fuses in cab and liftgate. in the
case of a blown fuse, check that visible
cables, cable glands and connectors
are securely fastened and on damaged.
Contact a qualified service engineer for
troubleshooting or repair.
Replace blown fuse / reset tripped circuit
breaker.
Check the main fuse. The cause of the
blown main fuse / tripped main circuit
breaker should be carefully investigated
before replacing/resetting. Contact a
qualified service engineer.
Other fault
Contact a qualified service engineer
The platform does not tilt all
the way up.
Oil level too low.
Lower the platform to the ground, fill with
oil to the maximum level.
Other problem
Contact a qualified service engineer