Vertical Multistage Centrifugal Pump

WALRUS PUMP CO., LTD.

TPR  Series

User Manual

ISO 9001 Certified

Содержание TPR Series

Страница 1: ...Vertical Multistage Centrifugal Pump WALRUS PUMP CO LTD TPR Series User Manual ISO 9001 Certified...

Страница 2: ...to the following directive 2006 42 EC Machinery directive 2014 35 EU Low voltage directive 2014 30 EU EMC Electromagnetic compatibility directive 2009 125 EC Ecodesign Directive Refer to the following...

Страница 3: ...TPR_N pumps in systems where all parts in contact with the liquid are made of high grade stainless steel TPR 1 4 S F RSSH Pump Dey to codes Example Code Description Code for materials S N SUS 304 SUS...

Страница 4: ...r is a totally enclosed fan cooled 2 pole standard motor Installation specifications 0 37 4 0kW V18 over 5 5kW V1 Insulation class F Enclosure class IP 55 and IP 54 Stops and Restarts 0 37 up to 4kw 3...

Страница 5: ...d m Read from the NPSH curve for the maximum value of the particular pump system Hf Loss from suction pipes m calculate from pump s maximum flow values Hv Vapor pressure m read from the vapor pressure...

Страница 6: ...erating pressure is exceeded the conical bearing in the motor may be damaged and the life of the shaft seal reduced see page 11 3 6 Minimum flow rate Due to the risk of overheating do not use the pump...

Страница 7: ...TPR TPRN 120 and 150 75 kW only vertically However the motor must neither fall below the horizontal plane nor be installed upside down Ensure that an adequate supply of cool air reaches the motor coo...

Страница 8: ...3 millimeters 5 5 The operating voltage and frequency are marked on the motor nameplate Make sure that the motor is suitable for the electricity supply on which it will be used 5 6 Overload protectio...

Страница 9: ...and open the isolating valve on the suction side 3 See the correct direction of rotation of the pump on the motor fan cover 4 Start the pump and check the direction of rotation 2 Remove the priming pl...

Страница 10: ...alve in the pump head At the same time open the discharge isolating valve a little 7 Close the vent valve when a steady stream of liquid runs out of it Completely open the discharge isolating valve 6...

Страница 11: ...rformance not constant Cause 1 Supply failure 2 Fuses are blown 3 Motor protective circuit breaker has tripped out 4 Thermal protection has tripped out 5 Main contacts in motor protective circuit brea...

Страница 12: ...re not being used during periods of frost should be drained to avoid damage 9 2 Scald Protection Do not touch the outer surface when the pump is used for hot liquid transmission 10 Coupling adjustment...

Страница 13: ...90 6 60Hz 1 2 1 25 1 27 3 2 3 15 3 17 3 25 5 2 5 9 5 10 5 24 10 1 10 5 10 6 10 17 15 1 15 2 15 3 15 12 20 1 20 2 20 10 32 1 1 32 3 32 3 2 32 6 32 7 2 32 10 2 45 1 1 45 1 45 2 2 45 3 45 4 2 45 7 64 1...

Страница 14: ......

Страница 15: ......

Страница 16: ...CC70D0022DA00EW0R02 03 WALRUS PUMP CO LTD Web www walruspump com...