2. INSTALLATION
2.1 TRANSPORTATION AND HANDLING
The equipment must be transported and handled exclusively in upright position, in
observance of the instructions printed on the packing.
This precaution is necessary to avoid contamination of the refrigerant circuit with compressor lube
oil with resulting valve and heat exchanger coil failure and problems starting the electric motor or
the risk of a gas leak. The manufacturer is not responsible for any problems due to transport
executed in conditions other than those specified herewith.
The equipment is secured to a wooden pallet base, wrapped in a plastic film and packaged into a
three waves carton box..
The equipment must be handled using a fork lift truck or a pallet truck with suitable forks (fork
length at least equal to 2/3 length of unit).
2.2 POSITIONING
Incorrect positioning can cause damage to the equipment and generate hazardous conditions for
personnel. The installer must therefore observe the following general regulations:
Make sure you maintain a minimum of 11
13
16
inches (30 cm). clearance from the back wall,
19
43
54
” (50 cm) from the side walls and the ceiling. The room must be well ventilated.
Keep well away from sources of heat. Avoid direct sunlight exposure.
Remove packing material.
Remove accessories from inside the unit.