Product Manual WDC400
Wallgate
2014
32
|Revision 3.0
8.
WDC400 Menu Settings
1.
Press and hold downhold down the
MENU
and keys for 5 seconds to display the
Main menu, the firmware version appears.
2.
Press the ↓ or ↑ keys to navigate the menu and submenus. You can also use these
keys to change the values of settings.
3.
Press the key to select a menu item, or to modify a setting.
4.
Press the
MENU
key to navigate up the menu tree by one level.
Table 5. WDC400 Menu Settings
Main Menu Item
Sub Menu 1
Sub Menu 2
Available Options
Default
Value
Firmware version number appears. Use ↓ key to view the main menu.
System Settings
Management
Start the System Test
System Test
Enabled or Disabled
Disabled
Enable or disable
Exclusivity
Exclusivity
Basin Excl.
Enabled or Disabled
Disabled
Shower Excl.
W.C. Excl.
Enable or disable
Water Lockouts
Water Lockouts
Enabled or Disabled
Disabled
Select the operating
mode and defaults
Mode & Defaults
Cell or Communal
Cell
Enable or disable
Cistern Sharing
Cistern Sharing
Enabled or Disabled
Disabled
Enable or disable the
High Voltage Flush
High Volt Flush
Enabled or Disabled
Disabled
Enable or disable
Double Press Flush
Double Press Flush
Enabled or Disabled
Disabled
Enable or disable the
Shower and Basin
infrared sensor inputs
I.R. INPUTS
Basin IR Input
Enabled or Disabled
Disabled
Shower IR Input
Enabled or Disabled
Disabled
Specify the Time and
Date
Set Date & Time
Set Time
HH:MM
Set Date
DD/MM/YY
Assign the Auxiliary
Inputs
Auxiliary Input
Setup
Remote Input 17
Remote Lockout, Remote
Flush, Half Flush, Not
Used, Main Light levels,
Epic, Chubb, Purge, reset
lockouts, bed light switch,
& main light 2
Bed switch main
light
Remote Input 18
EPIC
Remote Input 19
Remote Lockout
Remote Input 25
Bed switch main
light
Remote Input 26
EPIC
Remote Input 27
Remote Lockout
Reset the WDC400
settings to Factory
Defaults.
Load Factory Settings
Refer to the
WDCMS setup
procedure.
Network Address
1 to 30
1