WDC200-NX Electronic Water Management.
Revision-2
4
Clear lockouts remotely via the WDCMS Front End
5
Clear lockouts via BMS or SBC panel
8.8 Hygiene Purge
The Hygiene Purge can be operated from the Quick Functions menu. This will run
the W.C. for the number of cycles specified in the
Operation Count
setting. This will
run the Shower or Taps for the time specified in the
Operation Time
setting.
8.9 W.C.
The Water Closet (W.C.) is designed to operate a valve or OLI system depending on
the
Output Mode
setting. When the WC is activated, it will open the valve or OLI for
the time given in the
WC Full Flush Time
setting. After this the W.C. will not allow
further activations until the
WC Refill Time
has passed. If the
Double Press Flush
setting is enabled this will allow the W.C. to open the valve or OLI for the
WC
Reduced
time when activated. If the WC is activated a second time within 1 second
and before the
WC Reduced
time has finished, the valve or OLI will remain open for
the full
WC Full Flush Time
.
8.10
Shower
When activated, the Shower will open the valve for the length of time specified in the
Cycle Time
setting. Pressing the button again will not do anything to the shower
cycle unless
Interruptible
is enabled in which case the shower cycle will be
cancelled. As the shower nears the end of its cycle it is possible to have the valve
pulse off and on again as a warning if the
Shower End Warning Pulse
is enabled.
How long the water is pulsed off can be set with the
Pulse Length
, and the
Pulse
Time from End
setting can be used to specify how long before the end of the
shower cycle this pulse should occur. The Shower also allows for two input methods,
the first being a normal input button and the other being the E-Suite. This can be set
with the
System
setting.
8.11
Tap
When activated, the Tap will open the valve for the length of time specified in the
Cycle Time
setting. Pressing the button again will not do anything to the Tap cycle
unless
Interruptible
is enabled in which case the tap cycle will be cancelled. As the
tap nears the end of its cycle it is possible to have the valve pulse off and on again
as a warning if the
Tap End Warning Pulse
is enabled. How long the water is
pulsed off can be set with the
Pulse Length
, and the
Pulse Time from End
setting
can be used to specify how long before the end of the tap cycle this pulse should
occur. The Tap also allows for two input methods, the first being a normal input
button and the other being the E-Suite. This can be set with the
System
setting.