6.7 Check the Hydraulic Fluid Level
Check hydraulic fluid level every 40 hours or weekly.
Check with the machine parked on level ground and the engine
stopped.
The proper level is when the fluid is visible at the full (upper)
mark on the dipstick.
00638
Figure 9 –
Hydraulic tank fluid level dipstick
IMPORTANT! Do not operate machine if fluid level is not
visible on the dipstick. Damage to the pump and other
components can occur.
Do not overfill the tank past the full mark.
Always check fluid levels after changing filters or servicing
hydraulic components.
Hydraulic fluid quality should be inspected every 40 hours. If
the fluid is dirty or smells burnt, it should be replaced.
Be aware of high fluid temperatures. Temperatures higher
than 180 °F (82 °C) could cause seal damage and degrade
fluid quality.
6.7.1 Add Hydraulic Fluid
The hydraulic system uses
Dexron® III ATF
.
1.
Clean the area around filler cap and remove it.
2.
Use a clean funnel and add fluid until the level is at the full
mark on the dipstick.
3.
Install filler cap securely. Wipe up any spilled fluid.
6.8 Check the Fuel Level
Check the fuel level daily.
Starting with a full tank helps to eliminate or reduce operating
interruptions for refueling.
The fuel tank is located on the engine. Avoid running the tank
dry.
01778
Figure 10 –
Fuel cap
6.8.1 Add Fuel to the Engine
Fuel tank capacity:
0.82 US gal (3.1 L).
WARNING!
Never smoke or vape while working
with fuel. Fuel vapors can explode
causing injury or death. Keep sparks,
fl ames, and hot components away.
W027
Refuel in a well-ventilated area with the engine stopped. If the
engine has been running, allow it to cool first. Never refuel the
engine inside a building where gasoline fumes can come in
contact with flames or sparks.
Fluids and Lubricants on page 28
.
Refer to the engine manual for additional information on fuels.
1.
Clean the area around fuel tank cap.
Fill the tank to 1/2"
(12 mm) below bottom of filler neck to provide space for
any fuel expansion.
Do not overfill.
2.
Install fuel fill cap securely and wipe up any spilled fuel.