background image

G:\INSTRUCT\MERCHANT\MAXIPUMPS\MPEP3000 MPEP5000 Hydrojet Instructions 06-05-2019.docx 

 

 

6

th

 May 2019 Page 1 

 

WALLACE MAXIPUMPS (MPEP3000, MPEP5000) AND  

HYDROJETS (HJ60, HJ100, HJ140, HJ60PT, HJ100PT)  

INSTALLATION AND MAINTENANCE INSTRUCTIONS

 

 
Please read and follow all these instructions carefully before proceeding with the installation, this will ensure many 
years of trouble free pump performance, and protect your warranty. 
 

WARNING 

 

1/ This appliance is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for their safety. 
 
2/ Children should be supervised to ensure that they do not play with the appliance. 
 
3/ If the pump is not intended to be used for cleaning and other maintenance of swimming pools  
 
4). The electrical installation must be in accordance with national wiring rules and regulations. 
 
5). Where pumps are to be used in outdoor fountains, garden ponds and similar places the pump is to 
be supplied through a residual current device (RCD) having a rated residual operating current not 
exceeding 30 mA. 
 
6). If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard. 
 
7) Maximum fluid temperature should not exceed 35 

0

C. 

 

Applications:

 A Wallace MAXIPUMP OR HYDROJET automatic pressure system can supply house or garden.   

MPEP3000, MPEP5000, HJ60, HJ100, OR HJ140 provide a constant pressure at a constant flow.  HJ60PT OR 
HJ100PT will provide varying pressure within a set pressure band.   
MPEP3000, MPEP5000, HJ60PT, HJ100PT, HJ60, HJ100, OR HJ140 operate from above or below ground rain 
water tanks, spear points or any other clean water source. 
Suction lift capabilities of above pumps is as below provided they are installed to these instructions. MAXIPUMPS  
5m; HYDROJETS 6m.  
Operation of pumps with suction lifts of greater than – MAXIPUMPS 3m; HYDROJETS 4m – may significantly 
reduce pump performance.   
The MPEP3000, MPEP5000, HJ100, OR HJ140 are suitable to supply outlets up to max 15 metres vertically above 
the pump.  The HJ60, HJ60PT, HJ100PT are suitable for supply outlets up to 10 m above the pump.  For outlets 
that are to be higher contact Wallace Pumps. 
There is a built in delivery non-return valve in the controller of every MPEP3000, MPEP5000, HJ60, HJ100, OR 
HJ140.  The HJ60PT and HJ100PT do not have a non-return valve included.   
 

 

 

Содержание MAXIPUMP MPEP3000

Страница 1: ...rated residual operating current not exceeding 30 mA 6 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard...

Страница 2: ...maximum is 35 C Pressure Tanks Required The HJ60PT and HJ100PT require a pressure tank to operate and one is supplied with each pump The HJ60PT pressure tank air charge should be 18 psi 125 kPa The HJ...

Страница 3: ...tank to the same size as the selected pipe The pipe should be level or can go below then rise to the pump Pipes must not rise from the source and then fall to the pump Where possible the pipe should b...

Страница 4: ...kPa 30PSI 3 Prepare the pump housing ensure it will be easy to access the pump and tank for future servicing 4 Prime and install the pump in the housing 5 Install the suction pipework 6 Prime the pump...

Страница 5: ...not fully primed there has been a run dry e there is a suction or delivery pipe restriction When the pump is first turned on it may run for approximately 0 seconds and turn off the failure LED will be...

Страница 6: ...s more than 13 metres above the pump Call Wallace Pumps 4 Controller has activated due to run dry Restore water supply or system fault and prime pump press reset button to reset the controller Refer t...

Страница 7: ...d for large single level homes where piping lengths through the house can be very long Regular Servicing Ensure isolation and disconnection of the power supply to the pump before and whilst carrying o...

Отзывы: