Cleaning and Maintenance 

17 

Target Top 

 

a.  This should be kept clean of any build up of spillage’s of food.  Provided cast iron work surface is 

regularly used it will maintain itself in good condition with no special cleaning required. 

b.  Clean food residue and spillage from channels around centre casting and main plates before use. 

c. 

DO NOT use water on castings while they are still hot as cracking may occur.  

Should it 

be necessary to clean castings,

 

allow castings to cool and then remove for cleaning.  Clean using 

a soft cloth moistened with a mild detergent and hot water solution and a scrubbing brush.  Dry 

thoroughly with a dry cloth. 

d. 

Remove drip tray and clean with a mild anti bacterial detergent and hot water solution using a 

soft bristled brush.  

Dry drip tray thoroughly with a dry cloth. 

 

Stainless Steel Surfaces 

 

a.  Clean exterior surfaces of Target Top / Range with hot water, a mild detergent solution and a 

soft scrubbing brush.  Note that gas control knobs are a push fit onto gas control valve spindles 

and can be removed to allow cleaning of front control panel. 

b.  Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless 

steel wool.  Always apply cleaner when appliance is cold and rub in direction of grain. 

c.  To remove any discoloration, use an approved stainless steel cleaner or stainless steel wool.  

Always rub in direction of the grain. 

d.  Remove drip trays and clean with a mild anti bacterial detergent and hot water solution using a 

soft bristled brush.  Dry drip trays thoroughly with a dry cloth before re-fitting. 

e.  Dry all components thoroughly with a dry cloth and polish with a soft dry cloth. 

 

Periodic Maintenance 

NOTE:  All maintenance operations should only be carried out by a qualified service person. 

 

To achieve the best results, cleaning must be regular and thorough and all controls and mechanical parts 

should be checked and adjusted periodically by a qualified service person.  If any small faults occur, have 

them attended to promptly.  Don't wait until they cause a complete breakdown.  It is recommended that 

the appliance is serviced every 6 months. 

 

Gas Control Valve Re-Greasing 

The gas control valve should be dismantled and greased every 6 months to ensure correct operation 

of the gas control valve. 

 

To carry out this operation;- 

a.  Remove gas control knobs from gas tap spindles by pulling 

knobs away from control panel. 

b.  Remove drip tray from appliance. 
c.  Remove two screws on underside of control panel, securing 

control panel to hob. 

d.  Remove control panel from front of appliance. 

e.  Remove 2 screws holding shaft plate to gas control body and 

remove control shaft and plate.  

(See Fig 8).  

Note 

orientation of shaft for correct re-assembly. 

f.  Using needle nose pliers or similar, pull out gas control 

spindle, again noting its orientation. 

g.  Apply a suitable high temperature gas cock grease or 

lubricant such as ROCOL - A.S.P (Anti scuffing paste) /

Dry Moly Paste to outside of spindle.  

(See Fig 9).

 

h.  Replace spindle and re-assemble gas control valve in 

reverse order. 

i.  Refit control panel to appliance and secure with 2 

screws. 

j.  Refit knobs to gas control valve spindles. 

Two Screws 

Fig 8 

Spindle 

Fig 9 

Содержание RNB8110GE

Страница 1: ... O p e r a t i o n M a n u a l RN8110GE RNB8110GE RNL8110GE RNLB8110GE RN8110GEC RNB8110GEC RNL8110GEC RNLB8110GEC Gas Target Top Range Electric Ovens Date Purchased Serial Number Dealer Service Provider 229244 24 For use in GB IE ...

Страница 2: ...22 216 Spares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co u...

Страница 3: ...imensions 7 Installation 8 Installation Requirements Unpacking Location Clearances Assembly Rear Rollers Fitting Gas Connection Electrical Connection Commissioning Operation 13 Operation Guide Description of Controls Lighting Pilot Burner Target Top Lighting Main Burner Target Top Oven Cleaning and Maintenance 16 General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Fault Find...

Страница 4: ...THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning T...

Страница 5: ...utput two stage double ring cast iron burner offering accurate temperature control and infinitely variable heat with the heat radiating out from the centre of the Target Top The Main Burner is located underneath removable cast target top plates With heavy duty high efficiency electric static or convection oven options fitted with a 900mm 6 5kW electric static oven and a 6 6kW Convection Oven creat...

Страница 6: ...pane Input Rate N H G C 45 MJ hr 45 MJ hr Gas Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 60 kPa Gas Connection 3 4 B S P Male Natural Gas G20 Propane G31 Heat Input nett Nominal 11 5 kW 11 5 kW Reduced 4 7 kW 7 9 kW Gas Rate nett Nominal 1 22 m3 hr 0 89 kg hr Reduced 0 50 m3 hr 0 61 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 9 mbar 26 8 m...

Страница 7: ...between Nat Gas LP Gas and Butane but not Town Gas Refer to Gas Conversion and Specifications section of this manual for further details Gas Connection Gas supply connection point is located at rear of the appliance 130mm from right hand side 32mm from rear 655mm from floor and is reached from beneath appliance An optional underside connec tion is available Refer to the Dimensions section Connecti...

Страница 8: ... per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type Branch supply line shall be individually overload protected to correct current rating and supply chord shall be protected against any mechanical or thermal damage A grommet is fitted around wiring entry hole into appliance All wiring connections must be tight Refer to appropriate wiring standards for size of cable to be supplied t...

Страница 9: ...Dimensions 7 RN L 8110GE GEC ...

Страница 10: ...d the warranty Components having adjustments protected e g paint sealed by manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage ...

Страница 11: ...enable appliance to be easily moved for positioning and cleaning purposes If desired these rollers are supplied in packaging with appliance See below for fitting instructions Optional Accessories Refer to Replacement Parts List Plinth Kit For installation details refer to instructions supplied with each kit Fitting Rear Rollers 1 Raise appliance from floor by approx 75mm using suitable lifting equ...

Страница 12: ...se to appliance as possible NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to correct gas type that appliance will operate on Regulator outlet pressure is fixed ex factory for gas type that regulator is converted to and it is NOT to be adjusted Regulator connections are 3...

Страница 13: ...irements Table in Specifications Section 5 Connect neutral and earth conductors to neutral stud and earth stud respectively 6 For all connections ensure conductors are secure and appropriately terminated 7 Tighten cable gland to secure against tension on cable 8 Check that the polarity of each connection is correct to the mains connection terminals markings on the appliance NOTE Appliance must be ...

Страница 14: ...sure that this instruction manual is left with appliance Ensure that all relevant details and contacts have been added to front of this manual b Ensure operator has been instructed in areas of correct lighting operation and shutdown procedure for appliance 2 This manual must be kept by the owner for future reference and a record of Date of Purchase Date of Installation and Serial Number of Applian...

Страница 15: ...ating Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp green Target Top Gas Control Knob ๐ OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control ๐ OFF Position LOW Position 1 Position 2 Position 3 Position 4 Position HIGH Position Oven Thermostat Control ๐ OFF Position Temperature Graduations 50 C to 320 C Fig 5 This appliance is for professional use and is only to...

Страница 16: ... be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always set gas control knob to HIGH position when lighting main burner If pilot burner goes out during normal operation wait 5 minutes before re lighting 6 The cast iron work surface has a heat pattern that c...

Страница 17: ... top heat control to desired setting NOTE When oven top heat control is set to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operation With oven top heat control set on a low setting less heat is produced from top oven elements This mode is used for general baking purposes to prevent cakes etc from getting too brown and crisp on...

Страница 18: ...splash back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution of mild detergent and water Wipe dry with a clean dry cloth 3 Brush Target Top cast iron with a soft bristled brush followed by wiping with a cloth to prevent accumulation of carbon 4 Remove drip...

Страница 19: ...tion using a soft bristled brush Dry drip trays thoroughly with a dry cloth before re fitting e Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NOTE All maintenance operations should only be carried out by a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be ...

Страница 20: ...On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tight...

Страница 21: ...Wiring Schematic 19 RN8110GE ...

Страница 22: ...Wiring Schematic 20 RN8110GEC ...

Страница 23: ...Wiring Schematic 21 Wiring Layout for Static Oven Wiring Layout for Convection Oven ...

Страница 24: ...jectors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of unit before tightening 2 main burner securing screws 4 Set burner aeration screws X and Y for correct gas type aeration as shown in Gas Specifications Tables at rear of this section Pilot Burner 1 Di...

Страница 25: ...icks Refit 2 half plate castings ensure they are correctly interlocked Refit centre casting Refit front control panel and control knob Low Fire Adjustment NOTE Adjust low fire adjustment screw on gas control valve to as shown in Gas Specifications Tables at rear of this section 1 Light main burner and check flame size on simmer LOW position NOTE Low Fire Screw should be sealed with coloured paint ...

Страница 26: ...emains correct Re adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Identification Label On completion of gas conversion replace gas type identification label located at Rear of appliance above gas connection Beside the rating plate Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carr...

Страница 27: ...tor Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Injector Outer Ring Ø 2 60mm Ø 1 55mm Pilot Burner Injector 0 35 0 25 Burner Aeration Screw X Inner 25mm 25mm Burner Aeration Screw Y Outer 28mm 28mm Low Fire Adjustment 21 2 turns out ccw 1 turn out ccw Operating Pressure 1 0 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas LP Gas Propane Main Burner Injector Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Inj...

Страница 28: ...ed apart from when carrying out gas conversion if required Refer to details in this section for information Natural Gas G20 Propane G31 Main Burner Injector Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Injector Outer Ring Ø 2 60mm Ø 1 55mm Pilot Burner Injector 0 35 0 25 Burner Aeration Screw X Inner 25mm 20mm Burner Aeration Screw Y Outer 28mm 25mm Low Fire Adjustment 21 2 turns out ccw 1 turn out cc...

Страница 29: ...ersion and Specifications section of this manual for further details Natural Gas Town Gas Main Burner Injector Inner Ring Ø 1 70mm Ø 4 20mm Main Burner Injector Outer Ring Ø 2 60mm Ø 6 30mm Pilot Injector 0 35 0 70 Burner Aeration Screw X Inner 25mm 20mm Burner Aeration Screw Y Outer 28mm 22mm Low Fire Adjustment 21 2 turns out ccw Blank 11 2 turns out ccw Supply Pressure 1 13 3 40 kPa 0 75 1 50 k...

Страница 30: ...30 Injector Outer Ring Town Gas Ø 6 30mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75kW 750 Ovens 228690 Oven Bottom Element 3 75kW 750 Ovens 228082 Oven Top Element 2kW 900 1200 Ovens 228059 Oven Bottom Element 4 5kW 900 1200 Ovens 228704 Door Spring Kit 229021 Terminal Block Mains 227399 Control Knob Th...

Страница 31: ... mm Plinth Kit Gas Regulator Gas Conversion Kits NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be converted between Nat Gas LP Gas and Butane but not Town Gas Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 Town Gas 230185 BSP F F Adjustable BSP F F Convertible Model ...

Страница 32: ......

Отзывы: