1.2.4.  Deleting an OPERATOR code  

Procedure 

1.  With the lock open and the opening handle in the open position, press the 

MODE key; PRG-MOD appears in the display. 

2.  Enter existing MASTER-CODE (for initial programming 0 0 1 2 3 4 5 6), 

confirm with ENTER, TIME appears in the display. 

3.  Press arrow key until CODE appears, confirm with ENTER. 

4.  MASTER appears in the display, press the arrow key until BEDIENR 

appears, confirm with ENTER. 

5.  Select OPERATION 11-19 or OPERATION 21-29 with the arrow key. 

6.  Press DEL key, the display shows DELETE, select YES with arrow key and 

confirm with ENTER. 

15. ACCEPT appears in the display and the respective opening code is deleted. 

exit the menu by pressing the i key 2-3 times. 

 
 

1.2.5.  Deleting a MANAGER code  

Procedure 

1.  With the lock open and the opening handle in the open position, press the 

MODE key; PRG-MOD appears in the display. 

2.  Enter existing MASTER-CODE (for initial programming 0 0 1 2 3 4 5 6), 

confirm with ENTER, TIME appears in the display. 

3.  Press arrow key until CODE appears, confirm with ENTER. 

4.  MASTER appears in the display, press arrow key until MANAGER appears, 

confirm with ENTER. 

5.  Select MANAGER 1 or MANAGER 2 with the arrow key. 

6.  Press the DEL key, the display shows DELETE Select YES with the arrow 

key and confirm with ENTER. 

7.  ACCEPT appears in the display and the respective opening code is deleted. 

exit the menu by pressing the i key 2-3 times. 

 
 

1.2.6.  Time menu (setting time and date)  

Procedure 

1.  With the lock open and the opening handle in the open position, press the 

MODE key; PRG-MOD appears in the display. 

2.  Enter master code (for initial start-up 0 0 1 2 3 4 5 6) and confirm with 

ENTER. 

3.  TIME appears in the display, confirm with ENTER. 

4.  With digits enter current time and confirm with Enter. 

5.  SAVE, YES? Confirm with ENTER and AKEZPT is displayed. 

6.  Jump to DATE with right arrow key, confirm with ENTER. 

7.  Enter the date with digits, confirm with ENTER and ACCEPT is displayed. 

Exit the menu by pressing the i key 2-3 times. 

 

 

Содержание Tresore AXESSOR USB

Страница 1: ...www tresore ch OPERATING INSTRUCTIONS KEYPAD LOCK AXESSOR USB Electronic door lock for WA safes Issue 08 2020...

Страница 2: ...ave chosen a product tested according to EN1143 1 A Swiss quality product with VdS tested security Please read these instructions carefully before commissioning your safe Your contact for questions WA...

Страница 3: ...ogramming menu 3 1 2 1 Master code 3 1 2 2 Manager code 10 or 20 4 1 2 3 Operator code 11 19 or 21 29 4 1 2 4 Deleting an OPERATOR code 5 1 2 5 Deleting a MANAGER code 5 1 2 6 Time menu setting time a...

Страница 4: ...Enter key 3 The lock bolt is opened 4 Turn the opening rotary handle to the open position within 5 seconds and pull the door open This is signaled with a beep every 20 seconds 5 Each keystroke is ackn...

Страница 5: ...k 1 1 4 Code structure Master 00 for safety officer 00 XXXXXX Manager 10 10 XXXXXX Manager 20 20 XXXXXX User group 10 Operator 11 11 XXXXXX User group 20 Operator 21 21 XXXXXX Operator 12 12 XXXXXX Op...

Страница 6: ...MOD appears on the display 4 Enter existing MASTER CODE for initial programming 0 0 1 2 3 4 5 6 confirm with ENTER TIME appears in the display 5 Press arrow key until CODE appears confirm with ENTER 6...

Страница 7: ...e closed position the lock closes immediately test the new code at least 3 times with the door open 1 2 3 Operator code 11 19 or 21 29 Procedure 1 With the lock open and the opening handle in the open...

Страница 8: ...DE for initial programming 0 0 1 2 3 4 5 6 confirm with ENTER TIME appears in the display 3 Press arrow key until CODE appears confirm with ENTER 4 MASTER appears in the display press arrow key until...

Страница 9: ...g are not deleted by this Do not use rechargeable batteries rechargeable as their capacity is not sufficient for trouble free operation 1 3 1 Opening the battery compartment The battery compartment is...

Страница 10: ...8 IN2 white Door bolt position contact internal 7 GND white Door bolt position contact internal 6 IN1 red Remote lock 5 IN1 blue Remote lock 4 OUT1 A black Silent alarm 3 OUT1 B white Silent alarm 2 O...

Страница 11: ...ting backwards is also too easy Important passwords should be reconstructable 1 4 1 2 How to create a secure password The first rule A password is only secure if it remains secret Remember passwords d...

Страница 12: ...______________________________________________________________ _______________________________________________________________________________ _________________________________________________________...

Отзывы: