background image

 

500.0024-A

 

11 

Subject to technical changes

 

As soon as the input unit is supplied with 
power, the display shows one of these 
messages: "Battery case was open, 
battery inserted" or "Battery case was 
open, rechargeable battery inserted". 

 

6.

 

To delete the battery message, you must 
first press the ENTER key and then enter 
the master code (MA1) or the battery code 
(11111111). The lock can then be used 
again in the normal way. 

 

 

Malfunctions

 

4.1.

 

Battery

 

If there is insufficient battery voltage, the display shows the 

"

Battery flat

" message

If you observe the warning just mentioned, the battery for the lock must be replaced as 
quickly as possible (section 3.6.). 
The lock can be operated until the battery voltage drops below 6.5 volts. 
No codes or settings are deleted when a battery is replaced. You only need to check the 
date and time, and reset them if necessary (section 3.5.). 

  

 

 

 

NOTE:

 Do not use rechargeable AA batteries (accumulator batteries) because they do not 

have enough capacity to ensure fault-free operation! 

 

4.2.

 

Tamper block

 

After 5 invalid code inputs, the keypad is blocked for 6 minutes. The remaining lockout 
time is shown on the display, and it cannot be bypassed. If the incorrect code is entered 
again after the lockout time has elapsed, the lockout time of 6 minutes will start again. 
From the tenth successive incorrect input onwards, the lock will block inputs for 20 
minutes. The lockout time ends as soon as the valid code has been entered correctly. 
 

 

 

Содержание PAXOS ADVANCE DUAL LOCK

Страница 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK PAXOS ADVANCE DUAL LOCK Electronic safe lock for WA safes...

Страница 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Страница 3: ...ramming codes 7 3 4 1 User code 01 OCa1 and user code 02 OCb1 for lock 1 7 3 4 2 User code 01 OCa2 and user code 02 OCb2 for lock 2 8 3 4 3 Master code 00 MA1 8 3 4 4 Master code 00 MA2 9 3 5 Setting...

Страница 4: ...s it easy and clear to operate Various additional functions can also be used with the Paxos Advance 1 1 Operating controls WALDIS First and Premium Input unit Rotary opening handle NOTE These operatin...

Страница 5: ...l Pos 3 Arrow key up left Select the next menu item Select the next input value Pos 4 Arrow key down right Select the next menu item Select the next input value Pos 5 ENTER key Confirm inputs Call up...

Страница 6: ...to release the battery case that is slotted into the input unit from below and swivel it downwards and outwards 3 The battery holder B is inserted in the battery case release it from the case and fit...

Страница 7: ...ate time saved message 8 Press the ENTER key repeatedly and the display will show the Open menu message confirm this again with the ENTER key 9 The display shows the Lock code 1 message to indicate th...

Страница 8: ...the display shows the Lock 1 is opening message followed by Lock is open The display then shows the Lock code 2 message to indicate that user code 1 or 2 for lock 2 12223310 or 12223320 must be enter...

Страница 9: ...alarm which cannot be heard at your location can be sent to the alarm centre when the code to open the safe is entered in the normal way To trigger the threat alarm the value of the last two digits of...

Страница 10: ...99 88 77 Battery code BC94 11 11 11 11 The lock cannot be opened with this code it is needed to define the employee codes and the time functions The Paxos Advance electronic high security lock is norm...

Страница 11: ...pressing the ENTER key again 4 On the display use the arrow key to select Lock 2 and also confirm this with the ENTER key 5 Use any arrow key to select 01 OCa2 02 OCb2 and confirm with the ENTER key t...

Страница 12: ...current codes 2 Leave the rotary opening handle in the open position 3 On the input unit press the ENTER key confirm the Code functions menu that is shown on the display by pressing the ENTER key aga...

Страница 13: ...ine batteries LR6 E91 or AM3 into it As an option you can also insert a rechargeable battery pack A from Dorma Kaba in this case there is no need for the battery holder Operation with rechargeable bat...

Страница 14: ...ossible section 3 6 The lock can be operated until the battery voltage drops below 6 5 volts No codes or settings are deleted when a battery is replaced You only need to check the date and time and re...

Страница 15: ...ff 5 1 Assignment of terminals on the I O box The I O box has 8 inputs and 8 outputs connections for the power supply and an RS232 interface NOTE The I O box functions are only available when the I O...

Страница 16: ...on Connection with tamper monitoring switch factory configuration 3 IN2 4 GND Input 2 Standard bypass opening delay 5 IN3 6 GND Input 3 Standard interrupt lockout time 16 IN4 17 GND Input 4 Standard e...

Страница 17: ...at 50 C ext OUTx OUTx 9 OUT2 10 OUT2 Output 2 Standard all locks and door bolts open 11 OUT3 12 OUT3 Output 3 Standard resistance monitoring input sabotaged 22 OUT4 23 OUT4 Output 4 Standard external...

Страница 18: ...itoring of external power supply Output voltage 24 VAC power load at output 0 4 A at 25 C 0 3 A at 50 C ext NC 39 COM 40 NO 41 14 VDC 15 GND External power supply 12 VDC 24 VDC 700 200 mA ext I O box...

Страница 19: ...as far as possible the keypad shows signs of wear over time revealing the individual numbers used in the code Example of a good password Memorable sentence First letters of each word First letters in...

Отзывы: