Problem
Possible Cause
Corrective Action
Output fluctuates
Suction or discharge valve is
Disassemble, inspect, clean
clogged with foreign matter
Air is trapped in pump
Prime pump per instructions
Overfeeding
Install injection valve or back
pressure
valve
Check stroke length knob
(@ 0%, pump should not pump)
Diaphragm is damaged
Replace diaphragm
Worn check valves
Replace valve cartridges
Liquid leaks
Fitting or coupling nut is loose
Tighten
Pump head is loose
Tighten pump head bolts
Torque: 19 lb-in (2.16 N-m)
Diaphragm is damaged
Replace diaphragm
O-ring or valve gasket
Install o-ring or valve gasket
missing