Wahsega Labs WL-IC-FLMT-SIP-I-W Скачать руководство пользователя страница 1

 

 

 

Flush Mount 

SIP Access Control Intercom 

 
 

Installer’s Guide

 

 

 

 

 

 

 

This step-by-step guide will help you install your  

Wahsega Labs flush mount SIP access control intercom. 

 

Содержание WL-IC-FLMT-SIP-I-W

Страница 1: ...Flush Mount SIP Access Control Intercom Installer s Guide This step by step guide will help you install your Wahsega Labs flush mount SIP access control intercom...

Страница 2: ...A 1 VoIP intercom assembly B 4 Phillips head faceplate screws for drywall C 4 1 Phillips head faceplate screws for drywall D 1 3 pin male connector for controlling door access E 1 4 pin male connector...

Страница 3: ...cation point SIP server or Peer to peer device to call Network cable Cat 5 or Cat 6 Screwdriver Small flat head screwdriver Phillips head screwdriver Back box 4 11 16 square back box minimum 2 deep wi...

Страница 4: ...t to Exit and Door Latch Wiring The access control intercom provides connections for controlling magnetic door latches request to exit RTE functionality for buttons and or exit motion sensors as well...

Страница 5: ...gates and other points of entry Pin 1 is a 200mA fused 5V DC signal intended to provide power to the coil of an external relay Pin 2 is ground Pin 3 is the auxiliary output which is voltage and curre...

Страница 6: ...sed to switch a voltage or current which is beyond the direct switching capabilities of the Auxiliary Output Examples are higher voltages or AC signals In this configuration the 5V DC relay coil high...

Страница 7: ...y Powered Device This is normally used for a magnetic lock or other DC powered device The Auxiliary Output on Pin 3 provides the ground return path for the external load and the external power supply...

Страница 8: ...through 220 Connect to the NO of an SPDT NOTE 1 Pin 2 Door status ground reference pin Connect to Common Pin 3 Request to exit button and or exit motion sensor monitor line It can be wired as a ground...

Страница 9: ...Page 9 Door Status Monitor RTE Connector The RTE input can be wired in parallel with an RTE button and an exit motion sensor Both RTE and door status inputs go to Normally Open NO connections on corre...

Страница 10: ...www wahsega com Page 10 Flush Mount Installation...

Страница 11: ...the access control intercom needs at least 2 45 of clearance and will not fit in any other orientation 2 Conduit should be routed through a bottom or lower side knockout Connectors should not protrud...

Страница 12: ...fore installing the faceplate be sure to locate and note the access control intercom s MAC address which is printed on a white sticker on the rear of the circuit board 6 Attach the access control inte...

Страница 13: ...www wahsega com Page 13 Backbox Specifications Images not to scale Larger versions available at Wahsega com...

Страница 14: ...www wahsega com Page 14 Dimensions Images not to scale Larger versions available at Wahsega com...

Страница 15: ...ing RF emissions standards FCC 47 CFR Part 15 Subpart B Industry Canada ICES 003 Issue 5 Cet appareil num rique de la classe A est conforme la norme ICES 003 du Canada This product is designed manufac...

Страница 16: ...www wahsega com Page 16 Flush Mount SIP Access Control Intercom WL IC FLMT SIP I W Installation Guide Rev A 10 2 2015...