WAGO I/O System 750 

Device Description  15 

750-600/000-001 End Module with Potential Group 

 

 

 

Manual 

 

Version 1.0.1  

 

3.1 

View 

 

 

Figure 1: View  

Table 3: Legend for Figure “View” 

Pos.  Description 

Details See Section 

1  Marking possibility with Mini-WSB 

--- 

2  CAGE CLAMP

®

 connectors 

“Device Description” > … > 

“Connectors” 

3  Release tab 

“Mounting” > … > “Inserting and 

Removing Devices” 

4  Data contacts 

“Device Description” > … > 

“Connectors” 

 

 

 

 

 

 

Содержание TECHDOCS 750-600/000-001

Страница 1: ...Manual WAGO I O System 750 750 600 000 001 End Module with Potential Group I O Module for Terminating the Fieldbus Node with Potential Group Version 1 0 1...

Страница 2: ...il support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any inform...

Страница 3: ...nt 9 2 1 4 1 2 Packaging 10 2 2 Safety Advice Precautions 11 3 Device Description 14 3 1 View 15 3 2 Connectors 16 3 2 1 Data Contacts Local Bus 16 3 2 2 Power Jumper Contacts Field Supply 16 3 2 3 CA...

Страница 4: ...o the instructions in this manual and in the manual for the used fieldbus coupler or controller Consider power layout of the WAGO I O System 750 In addition to these operating instructions you will al...

Страница 5: ...Indicates a moderate risk potentially hazardous situation which if not avoided could result in death or serious injury Personal Injury Indicates a low risk potentially hazardous situation which if not...

Страница 6: ...mentation WAGO I O System 750 750 600 000 001 End Module with Potential Group Manual Version 1 0 1 Additional Information Refers to additional information which is not an integral part of this documen...

Страница 7: ...d data files are marked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item fr...

Страница 8: ...oller should always be carried out by qualified personnel with sufficient skills in PLC programming 2 1 3 Use of the 750 Series in Compliance with Underlying Provisions Fieldbus couplers controllers a...

Страница 9: ...ecified Devices The devices to be supplied ex works are equipped with hardware and software configurations which meet the individual application requirements These modules contain no parts that can be...

Страница 10: ...nic equipment sent to your local collection point Improper disposal of electrical and electronic equipment can be harmful to the environment and human health 2 1 4 1 2 Packaging Packaging contains mat...

Страница 11: ...ction against contact Prevent fire from spreading outside of the enclosure Offer adequate protection against UV irradiation Guarantee mechanical stability Restrict access to authorized personnel and m...

Страница 12: ...e a suitable fuse Do not exceed the maximum total current for I O modules 5 VDC via data contacts The maximum permissible total current for internal system supply of the I O modules may not be exceede...

Страница 13: ...tive for handling devices modules Clean only with permitted materials Clean housing and soiled contacts with propanol Do not use any contact spray Do not use any contact spray The spray may impair con...

Страница 14: ...Device Description An end module must be snapped onto the assembly at the end of a fieldbus node The end module completes the internal data bus while providing correct data transmission The 750 600 00...

Страница 15: ...l Version 1 0 1 3 1 View Figure 1 View Table 3 Legend for Figure View Pos Description Details See Section 1 Marking possibility with Mini WSB 2 CAGE CLAMP connectors Device Description Connectors 3 Re...

Страница 16: ...troller and the I O modules as well as the system supply of the I O modules is carried out via the local bus It is comprised of 6 data contacts which are available as self cleaning gold spring contact...

Страница 17: ...MP Connectors Figure 3 CAGE CLAMP Connector Table 4 Legend for Figure CAGE CLAMP Connector Designation Connector Function 0 230 V 1 Potential distribution 0 230 VAC DC 8 3 3 Display Elements The I O m...

Страница 18: ...18 Device Description WAGO I O System 750 750 600 000 001 End Module with Potential Group Manual Version 1 0 1 3 5 Schematic Diagram Figure 4 Schematic Diagram...

Страница 19: ...P connectors Current carrying capacity CAGE CLAMP connectors 10 A Isolation to adjacent I O modules and system field Rated voltage Unominal AC 300 V per EN UL 61010 2 201 Insulation type Reinforced in...

Страница 20: ...rotection type IP20 Resistance to harmful substances Acc to IEC 60068 2 42 and IEC 60068 2 43 Maximum pollutant concentration at relative humidity 75 SO2 25 ppm H2S 10 ppm Special conditions Ensure th...

Страница 21: ...75199 for use in Ordinary Location UL E198726 for Use in Hazardous Locations Cl I Div 2 Group A B C D T4 The following ship approvals have been granted to 750 600 000 001 I O modules DNV Det Norske Ve...

Страница 22: ...and Guidelines 750 600 000 001 I O modules meet the following requirements on emission and immunity of interference EMC CE Emission of interference EN 61000 6 3 EMC CE Immunity to interference EN 6100...

Страница 23: ...otential equalization from the environment The devices are equipped with electronic components that may be destroyed by electrostatic discharge When handling the devices please ensure that environment...

Страница 24: ...e left side cannot be snapped from the top This mechanical coding helps to avoid configuration errors which may destroy the I O modules Therefore insert I O modules only from the right and from the to...

Страница 25: ...4 2 2 Removing the End Module 1 Remove the end module from the assembly by pulling the release tab Figure 6 Removing the End Module The electrical connections for the data contacts are disconnected wh...

Страница 26: ...to each CAGE CLAMP Do not connect more than one conductor at one single connection If more than one conductor must be routed to one connection these must be connected in an up circuit wiring assembly...

Страница 27: ...0 1 5 2 Connection Examples The following connection examples are possible in connection with the I O module 750 677 0x0 000 Figure 8 Connection to I O Module 750 677 all Channels with Inverted Confi...

Страница 28: ...e 3 CAGE CLAMP Connector 17 Figure 4 Schematic Diagram 18 Figure 5 Snap the End Module into Place 24 Figure 6 Removing the End Module 25 Figure 7 Connecting a Conductor to a CAGE CLAMP 26 Figure 8 Con...

Страница 29: ...Notation 7 Table 2 Font Conventions 7 Table 3 Legend for Figure View 15 Table 4 Legend for Figure CAGE CLAMP Connector 17 Table 5 Technical Data Device 19 Table 6 Technical Data Rated Voltages 19 Tab...

Страница 30: ...WAGO GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 49 571 887 0 Fax 49 571 887 844169 E Mail info wago com Internet www wago com...

Отзывы: