82 •
750-671 [Steppercontroller]
Positioning
WAGO-I/O-SYSTEM
750
I/O
Modules
2.1.2.11.1.4.1
Positioning Process Image
The Positioning process image represents the standard configuration for
stepper positioning control and is shown in the following tables.
Off
set
Input Data
Output Data
0
S0 Status byte S0
C0 Control byte C0
1 Reserved
Reserved
2
D0 Actual Velocity L
D0 Velocity L
3
D1 Actual Velocity H
D1 Velocity H
4 D2
Reserved
D2
Acceleration
L
5 D3
Reserved
D3
Acceleration
H
6
D4 Actual position L
D4 Target position L
7
D5 Actual position M
D5 Target position M
8
D6 Actual position H
D6 Target position H
9
S3 Status byte S3
C3 Control byte C3
10
S2 Status byte S2
C2 Control byte C2
11
S1 Status byte S1
C1 Control byte C1